Office of Executive Engineer ED-Reasi
Office of Executive Engineer ED-Reasi
Supply, Installation, Testing and Commissioning of LED Lights i.e. 50 Watt, 100 Watt and 150 Watt in Indoor Stadium Reasi within the jurisdiction of Electric Division-Reasi on turnkey basis during the Financial Year 2026-27
2026_PDD_327265_1
E-nit 23 of 2026 Dated 05-10-2026
Open Tender
Electrical Works
Turn-key
30 days
ED Reasi
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Executive Engineer ED-Reasi
₹1,500
6 Oct 2026
6 Oct 2026
13 Oct 2026
6 Oct 2026
12 Oct 2026
6 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing, Commissioning & Two year maintenance of 50 watt,100 watt,150 watt +/- (5 watt max) LED Lights with each LED having power rating from 1 w to 2 w (make Philips/ Havells/ Syska Panasonic/ HPL) to be installed with Multi Stranded 1.5mm Sq copper wire (Anchor/Havells/Finolex/HPL) laid in suitable PVC conduit.(Complete job) | |||||
| 1.01 | Supply, Installation, Testing, Commissioning & Two year maintenance of 50 watt +/- (5 watt max) LED Lights with each LED having power rating from 1 w to 2 w (make Philips/ Havells/ Syska Panasonic/ HPL) to be installed with Multi Stranded 1.5mm Sq copper wire (Anchor/Havells/Finolex/HPL) laid in suitable PVC conduit.(Complete job) falling under the jurisdiction of Electric Division-Reasi, JPDCL. | 12 | Job | - | - |
| 1.02 | Supply, Installation, Testing, Commissioning & Two year maintenance of 100 watt +/- (5 watt max) LED Lights with each LED having power rating from 1 w to 2 w (make Philips/ Havells/ Syska Panasonic/ HPL) to be installed with Multi Stranded 1.5mm Sq copper wire (Anchor/Havells/Finolex/HPL) laid in suitable PVC conduit.(Complete job) falling under the jurisdiction of Electric Division-Reasi, JPDCL. | 11 | Job | - | - |
| 1.03 | Supply, Installation, Testing, Commissioning & Two year maintenance of 150 watt +/- (5 watt max) LED Lights with each LED having power rating from 1 w to 2 w (make Philips/ Havells/ Syska Panasonic/ HPL) to be installed with Multi Stranded 1.5mm Sq copper wire (Anchor/Havells/Finolex/HPL) laid in suitable PVC conduit.(Complete job) falling under the jurisdiction of Electric Division-Reasi, JPDCL. | 6 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
SBD23.pdf
Tender Documents • 1.15 MB
BOQ_1107208.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .