Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC RATES ARE REASONABLE | |
| 2 | L2₹39.4 L+₹3.6 L (10.2%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹40.3 L+₹4.6 L (12.8%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹43.8 L+₹8.0 L (22.5%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical Contractor not having reqd category |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
30 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR / MAINT OF EXTERNAL HT ELECTRIC SUPPLY UNDER GE GANGTOK
2021_MES_450394_1
CWE/136-WE/12 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE GANGTOK
Class D, Category b(ii)
8 documents required · 8 mandatory
₹500
GE Gangtok
₹70,000
Yes
27 Jul 2021
10 Jun 2021
1 Jul 2021
10 Jun 2021
30 Jun 2021
25 Jun 2021
10 Jun 2021 - 17 Jun 2021
60 days
Amount
Dismantling/Taking out of old unserviceable HT cable from any location complete all as specified and directed.
Removing of unattended / abondoned poles with ACSR conductor from different area including all brackets and clamps complete and deposit to MES store yard complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning HT XLPE cable cross sectional area 95 Sqmm 3 core, 11000 Volt screened, PVC bedded "Earthed grade" insulated bedded, galvanized steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system conforming to IS-7098 Part-II laid in pipe / ducts / trenches, under floor and road or fixed to wall etc complete all as specified and directed.
M&L in replacement of cable jointing kit suitable for HT 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
M&L in replacement of cable jointing kit suitable for HT 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm., complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.50m wide and not exceeding 1.50m deep for laying of HT under ground cable and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supply and laying in trenches or in cable ducts, DWC HDPE pipe of size 120mm (OD) x 103.5mm (ID) along with connected accessories like couplers, bends, end caps etc. for cable protection all as specified and as directed.
M&L for laying of GI pipe 80 mm bore, light grade for passing through cables under the floor / road etc complete all as specified and directed.
Dismantling of old unserviceable HT 11 KV Air break switch removing from site and replacement with new HT 11 KV Air break switch, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps including providing jelly for all moving and fixed contacts all as specified and as directed.
M&L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp working pressure 11000 volts including dismantling old unserviceable one complete all as specified and directed.
M&L for HT Drop out fuse assembly with 11 KV insulator and steel frame etc upto 200 amp capacity outdoor type including dismantling old unserviceable one complete all as specified and directed.
M & L of earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate electrode not less than 1.5 m below normal ground level, connected to including galvanised iron strip size 32 x 6 mm by means of bolts, nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earth test point including provision of earth strip protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of strata, PCC pit with RCC cover, CI frame, char coal, salt & funnel etc complete all as specified or indicated including testing on completion all as specified and directed. (Rate to be considered for earth strip to be fixed 7.5m long)
Dehydration of transformer oil with transformer oil filtration plant with heating and vaccum dehydration system complete at different location under GE Gangtok substation upto dielectric strength 40 KV/2.5 mm gap complete all as specified and as directed.
Supply & Top up of transformer oil upto conservator level marking with new oil as per IS 335 having dielectric strength not less than 40 KVA at 2.5 mm gap complete all as specified and as directed.
M&L for replacement of HT 11 KV bushing with brass terminal neoprene rubber gasket and washers etc complete all as specified and directed.
M&L for replacement of LT 1100 Volts bushing with brass terminal neoprene rubber gasket and washers etc complete all as specified and directed.
M&L for replacement of unserviceable breather asembly with silica gel of transformer 11/0.433KV of capacity 100KVA to 400 KVA complete all as specified and directed.
Preventive maintenance to vacuum circuit breaker indoor type by disconnecting of HT Supply and racking out, Strip opening the cover and replacement of HT incoming/outgoing bushing and insulator including cleaning applying petroleum jelly in fixed and moving parts, checking the tension of charging spring and all connected terms including testing and commissioning of VCB and for servicing /minor reapir and after Servicing, braker should be reconnected in all respect all as per existing arrangement and restore the supply complete all as specified and directed.
Caliberation of numerical type 3)/C + 1 E/F relay having CTR 5A, auxilliary voltage 110V DC complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out Hard/dense soil complete all as specified and directed.
M&L for loose filling 20 to 40 mm size graded coarse aggregate spread and levelled complete all as specified and directed.
Demolition of stone or boulders masonry built in cement mortar including all quoins, arches, pillars, pre-cast PCC bond stones, dressed stonework and precast concrete articles with separating seviceable stones and setting aside for reuse in the work complete all as specified and directed.
M&L for walling of random rubble or polygonal rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement morter (1:6) including brought up to course all as specified and directed.
Testing of transformer including disconnecting HT and LT cables, earthing connection and reconnecting HT and LT cables, earthing connection after conduction of testing including minor materials, test format shall be submitted in described format:- (a) Transformer capacity (b) Location (c) Make (d) Make Ser No (e) MES No (f) Insulation value (IR value):- (i) Megger voltage (ii) Megger Ser No (iii) HT side insulation value (iv) LT side insulation value (v) HT side to LT side (g) Dielectric strength of oil (h) Earth Value (i) Earth magger Ser No (ii) Earth Pit value I, II, III & IV (j) Breather condition All as specified and directed by Engineer-in-Charge.
M&L for preparation of old or new steel surfaces of any description not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on 11 KV s/s out door structure/ out door panels or any other complete all as specified and directed.
M&L for painting to two pole structure 11 mtr long, steel tubular any type with one coat of aluminium paint after preparation of surface of the pole including numbering of pole complete all as specified and directed.
M&L for painting to four pole structure 11 mtr long, steel tubular any type with one coat of aluminium paint after preparation of surface of the pole including numbering of pole complete all as specified and directed.
M&L for painting to Six pole structure 11 mtr long, steel tubular any type with one coat of aluminium paint after preparation of surface of the pole including numbering of pole complete all as specified and directed.
Supply, fixing and replacement of Electric shock treatment board, with discription of 3 language complete all as specified and as directed.
Dismantling the old unserviceable installation "LAY OUT DIA GRAM" boards indoor type and M&L for new "LAY OUT DIA GRAM" boards complete with vinyle graphics with hyflex as base supports frame of size 1.5 x 1.2 Mtr complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Damdoo Bhutia
Janata Enterprises
S K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .