Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.6 L+₹9.3 L (24.8%)Rejected-Finance | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹48.4 L+₹11.1 L (29.7%)Rejected-Finance | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹52.5 L+₹15.1 L (40.5%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹63.4 L+₹26.1 L (69.9%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Jan 2023, 6:00 pmClosed
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
REPAIRS AND MAINT LT CONTROL PANELS, UNDER GROUND LT CABLE AND OTHER CONNECTED ITEMS UNDER GE (W) COLABA, MUMBAI
2023_MES_573259_1
8706/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹80,000
Yes
20 Feb 2023
5 Jan 2023
3 Feb 2023
5 Jan 2023
31 Jan 2023
18 Jan 2023
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
All as per sl. item No.01 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth and getting out in hard rock cutting by chiselling/road cutting/RCC/PCC all as specified and directed.
Supply and providing stone crushed sand for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts all as specified and directed. Note:. for the purpose of payment only punned thickness will be measured.
Returning, filling in including spreading, levelling, watering ,well ramming in layers n.exc 25 cm in soil all as specified and directed.
Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point in soft /loose soil all as specified and directed.
Removing of excavated material from the site of work and transporting out of MoD land all as specified and directed.
Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made covers) Class LV type I, flat size 250x150x40 mm putting adjecent to each other including taking out old cable covers all as specified and directed.
Supply and laying tubes light grade, galvanized 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable including taking down old pipe all as specified and directed.
Supply and laying tubes light grade, galvanized 80 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable including taking down old pipe all as specified and directed.
Supply and laying tubes light grade, galvanized, 50 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as specified and directed.
M&L PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) in width for foundatuion/road filling including including rafts, footings, foundation beams plinth beams, bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
Taking down for old cable after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated of any size all as specified and directed.
M&L in repairs for cable jointing kit for LT cable XLPE aluminium conductor including testing and commissioning of size of 50sqmm X 3.5 core all as specified and directed
All as per item No 14 above but of size 70sqmm X 3.5 core all as specified and directed
All as per item No 14 above but of size 95sqmm X 3.5 core all as specified and directed
All as per item No 14 above but of size 120sqmm X 3.5 core all as specified and directed
All as per item No 14 above but of size 240sqmm X 3.5 core all as specified and directed
All as per item No 14 above but of size 300 sqmm X 3.5 core all as specified and directed
Taking out/down for old cable and rerouting, relaying the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 10 sqmm X 2 core to 50sqmm X 3.5 Core including connecting up electric power to panel/feeder box all as specified and directed.
Taking out/down for old cable and rerouting, relaying the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 70 sqmm X 3.5 Core to 185sqmm X 3.5 core including connecting up electric power to panel/feeder box all as specified and directed.
Supplying, laying, commissioning & testing LT underground cables, 16 Sqmm X 4 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Copper conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on wall, as and when required on ground for power supply of Lift all as specified and directed.
All as per item No 22 above but 10 Sqmm X 4 Core
Supplying, laying, commissioning & testing LT underground cables, 300 Sqmm X 3.5 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -I) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground all as specified and directed.
All as per item No 24 above 240 Sqmm X 3.5 Core
All as per item No 24 above 185 Sqmm X 3.5 Core
All as per item No 24 above 150 Sqmm X 3.5 Core
All as per item No 24 above 120 Sqmm X 3.5 Core
All as per item No 24 above 95 Sqmm X 3.5 Core
All as per item No 24 above 70 Sqmm X 3.5 Core
All as per item No 24 above 50 Sqmm X 3.5 Core
All as per item No 24 above 35 Sqmm X 3.5 Core
Supply, install, testing and commissioning of LT Panel meter cabin panel indoor type, mounted on angle iron frame made of 40x40x5 mm grouted on floor, cubical indoor type for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 250 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface all as directed comprising of the following :- Location:- Backbay1 & Marshal House. (a) MCCB, FP, 160 Amps 25 kA- 01 Nos. Make-Legrand / Schneider / L&T (b) MCB 63 Amps, 10KA, C series - 07 No . Make-Legrand / Schneider / L&T (c) Sheet metal enclosure 2 way without bus bar - 07 No, Make-Legrand / Schneider / L&T (d) Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE (e)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (f) Phase indicator lamp R,Y & B (g) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 07 Nos. (h) Material and labour for 2 core 16 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads.
Supply, install, testing and commissioning of LT Panel indoor meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor, cubical indoor type for 415V, 3 phase, made of 2.00 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Location:- P-64, P-65 (a) MCCB, FP, 200 Amps 25 kA- 01 Nos. I/C Make-Legrand / Schneider / L&T (b) MCCB, FP, 100 Amps 25 kA- 02 Nos.(I/O) Make-Legrand / Schneider / L&T (c) MCCB, FP, 63 Amps 25 kA- 01 Nos.(O/G) Make-Legrand / Schneider / L&T (d) MCB 40 Amps, 10KA, C series - 13 No . Make-Legrand / Schneider / L&T (e) Sheet metal enclosure 2 way without bus bar - 11 No, Make-Legrand / Schneider / L&T (f ) Copper Bus bar, 300 Amps Rated - R,Y,B & N (g) Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE (h)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (i) Phase indicator lamp R,Y & B (j) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 25 Nos. (k) Material and labour for 2 core 16 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads. (l) Fixing of submain cable 2 core 16 Sqmm copper conductor with outgoing of energy meter all as directed. (m) Fixing of submain cable 2 core 16 Sqmm copper conductor with outgoing of energy meter all as directed.
Supply, install, testing and commissioning of LT indoor meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, made of 2.00 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 150 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary formwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Location:- P-64, P-65 (a) MCCB, FP, 100 Amps 25 kA- 01 Nos. I/C Make-Legrand / Schneider / L&T (b) MCCB, FP, 63 Amps 25 kA- 01 Nos.(O/G) Make-Legrand / Schneider / L&T (c) MCB 40 Amps, 10KA, C series - 13 No . Make-Legrand / Schneider / L&T (d) Sheet metal enclosure 2 way without bus bar - 11 No, Make-Legrand / Schneider / L&T (e) Copper Bus bar, 200 Amps Rated - R,Y,B & N (f) Digital Ammeter-01 No, Make-HPL ,SP CL-1.0/AE (g)Digital Voltmeter-01 No Make-HPL ,SP CL-1.0/AE (h) Phase indicator lamp R,Y & B (i) Making provision for fixing of digital electronic meters removed from old panel including fixing and providing vision glasses - 25 Nos. (j) Material and labour for 2 core 16 Sqmm multistranded copper conductor cable 1100V form bus bar to electronic energy meters using suitable size copper thimbles/glads. (k) Fixing of submain cable 2 core 16 Sqmm copper conductor with outgoing of energy meter all as directed. (l) Fixing of submain cable 2 core 16 Sqmm copper conductor with outgoing of energy meter all as directed.
M&L for repairs/ Overhauling/Servicing to Existing LT electric feeder panels outdoor type by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as specified and directed . Note : (i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers. (iii) Replacing the burnt out colour coated PVC Sleeves of main and fedders bus with appropriate size of New PVC heat shrinkable sleeves -01 Job. (iv) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT' switch 2.5/1.5Sqmm copper single core, 1100V grade copper conductor cable- 01 Job. (v) Replacing Burnt out Insulators of incomming and out going feeders with appropriete size new Insulators -01 Job
M&L for spray painting to indoor/outdoor type, Feeder Panel installed at different locations of GE (west) Colaba area after scraping throughly the existing corroded paint/rust, filing of cavities and applying two coats of heat resistant paint of approved quality of required colour and writing/marking the In/ Out cables and MCCBs etc. all as per specified and directed by Engr - in - Charge.
M&L for earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level & connected to GI earth lead strip 25 x 4 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES Sschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, type C1), Precast RCC cover slab 55 cm x 55 cm x 5 cm thick with reinforcement 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in precast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil all as specified and as directed testing on completion.
S&F in repairs earth continuty conductor fixed to wall/surface or recess or burried in ground or any other situation for loop earthing by aluminium 25 X 4 mm, GI strip all as specified and directed by Engineer-in-Charge.
NOEL ENGINEERS
Ashish Enterprises
shree arihant constrution
NATIONAL ENGINEERING CORPORATION
Shree Ayyappa Engineering
Bidder Name
NATIONAL ENGINEERING CORPORATION
Ashish Enterprises
NOEL ENGINEERS
shree arihant constrution
Shree Ayyappa Engineering
SHREE SHIV ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .