Provision of FAT set up at Danapur, Shifting of S&T cable at BKP Station including Replacement of Point machine, relays & replacement of IPS old version at various stations under Danapur division
DNRSandTSig2026-20~ECR
DNRSandTSig2026-20
Open
Works - General
12 Months
Patna, Bihar
₹0
₹2.9 L
28 Oct 2026
28 Oct 2026
5 Nov 2026
103 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,43,61,208.63 | ||
| — | 1.00 | — | — | ||
| Laying cable of different sizes as per cable route plan approved by Railway. -Telecom cable/6 Quad cable. | — | — | — | 12,052.23 | |
| — | 35.00 | — | — | ||
| Supply of full size location box as per design of GKP signal workshop.( DRG No- SW/SK/4/90) Inspection-RITES | — | — | — | 10,00,025.6 | |
| — | 35.00 | — | — | ||
| "Casting,Concreting and Curing of foundation and erection for full apparatus case (GKP-type) as per DRG No. SGW/MGS/L1/91 includong cost of all materials required for fixing holding down bolts, casting, concreting and fixing o f ""E"" type lock. Note- i)The contractor will provide holding down bolts. ii)Bottom of appratus cases should be filled with sand and thetop surface covered with masonry work and neat cementing." | — | — | — | 2,17,944.3 | |
| — | 32.00 | — | — | ||
| Fixing,wiring of terminal strips,bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for full appratus case. (All materials except transformers, relay, terminal strips, bakelite strip and fuses with base to be spplied by the contractor. | — | — | — | 1,86,407.68 | |
| — | 10.00 | — | — | ||
| Supply of Thermoshrink jointing kit for 2T joints-6 quad. Inspection-Consignee | — | — | — | 51,256.4 | |
| — | 10.00 | — | — | ||
| Installation of Thermoshrink jointing kit | — | — | — | 42,184.2 | |
| — | 100.00 | — | — | ||
| Supply & installation of Disconnect type Terminal, screwless, 2 IN 2 OUT (as per spec. no. RDSO/SPN/189/2004 or latest)along with all accessories including separators for fixing on Cable Termination Rack/Location boxes for Cable Termination Purpose. Inspection-RITES | — | — | — | 10,583 | |
| — | 6500.00 | — | — | ||
| Excavation of trench in all kinds of soil and refilling of trenches (1.0 Mtr. Depth 300 mm width)-iii) Without bricks | — | — | — | 2,34,975 | |
| — | 2.00 | — | — | ||
| Laying/drawing of OFC through HDPE pipe/PVC pipe for OFC by blowing as advised by site engineer. | — | — | — | 38,409.04 | |
| — | 6.00 | — | — | ||
| Supply and installation of Optical fibre cable joint enclosure and making straight through joints for 24 fibre cable and testing. This includes splicing and making pits of size 1.2M dia x 1.2 M depth with top cover slab as per drawing 3. Inspection-Consignee | — | — | — | 1,97,955.48 | |
| — | 2.00 | — | — | ||
| Supply & Laying of HDPE pipe 40 mm OD, 33 ID with remaining materials in the trenches as per RDSO spec n o . RDSO/SPN/ TC /45/2013 Rev.2 Amndt No 2 or latest. It includes transportation of HDPE pipe from railway store to site & returning of left over material as per directions of engineer incharge/site engineer. Supply Inspection-RITES | — | — | — | 2,27,829.6 | |
| — | 2.00 | — | — | ||
| "Supply & Laying of HDPE pipe 40 mm OD, 33 ID with remaining materials in the trenches as per RDSO spec no. RDSO/SPN/ TC /45/2013 Rev.2 Amndt No 2 or latest. It includes transportation of HDPE pipe from railway store to site & returning of left over material as perdirections of engineer incharge/site engineer. Execution" | — | — | — | 23,519.8 | |
| — | 100.00 | — | — | ||
| Termination of cable cores on ARA terminals or on 8 way terminals in the cable termination rack.This includes all associated works of pulling out the cable from under ground,Peeling off insulation,dressing of cable core supported on sting rod with contractors own materials as per instruction of the site incharge. The cable armour to be earthed. Cable tags to be provided. | — | — | — | 1,571 | |
| — | 5.00 | — | — | ||
| Supply o f cable termination box. Spec.no.IRS-TC-18-75 with locking arrangements and termination o f derivation cable a s p e r the technical supplements. -20 pairs Inspection- Consignee | — | — | — | 17,095 | |
| — | 10.00 | — | — | ||
| Supply of earth electrode.Materials to be procured as per E.Rly Sketch No.SGW/T/3/G/8/89.Inspection- RITES | — | — | — | 20,087 | |
| — | 10.00 | — | — | ||
| "Installation of Earth Electrode including supply of MS Flat for clamp Signalling equipmentsuch as apparatus cases, Signal posts, etc." | — | — | — | 56,510 | |
| — | 100.00 | — | — | ||
| "Excavation of trench less trench /manual boaring (size upto 110 MM) upto a depth of minimum 1.0 Meter along with dia HDPE/ DWC pipes and its accessories, all other items which will be required for laying of cable through HDPE/DWC pipes as per requirement atsite." | — | — | — | 89,880 | |
| — | 1000.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level as per site requirement. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This include insertion of different dia HDPE pipe coupling etc. (pulling up to 72 Core in a single pipe) as per direction of Engineer In charge. Note:- This includes supply of HDPE/DWC pipes and accessories, cost ot fuels & all other items which will be required for laying of cable through it.. The work shall be executed as per instruction of site engineer. Pipe Inspection- Consignee | — | — | — | 11,04,770 | |
| — | 90.00 | — | — | ||
| Fixing, wiring, testing & adjustment o f electrical point machine TWS high thrust per standard practice. the item also includes (i) complete material for installation of point machine and fixing of ground connection/ switch extension P/D bracket insulator materials, S pipe, wiring materials, various nuts and bolts including casting NUTs and spring washer etc., adjusting the correct opening of switches and adjusting the point machine with crank handle. (ii) Wiring inside the point machine ,insertion and termination of tail cable in point machine and junction box/hut as per railways practice and instruction of site engineer . (iii) Supply & Fixing of GI pipes with flange for taking cable in to point machine and Jn. Box through gland/GI pipe. (iv)Complete material for insulation viz. point insulation material, GI Pipe/gland pipe, wiring material, nut & bolts of various sizes, MS channels 2 Nos. of length (350*125*50 mm) etc. as per site requirement for fixing the machine ,lugs for the point rodding and insulation material for the stretcher bar 90R/52kg/60kg as per RDSO Drg. no. SA-23171 (Adv.) Alt. 1,SA-23172 (Adv.) Alt. 1 will be supplied by the contractor (v) Smithy and fitting work required at site for complete installation, instalation of gauge tie plate and insulation o f GTP a s per Drg. No. NR/S&T/CON/7.6/97 and william stretcher bar (if required) will be done by the contractor .Also Machine will be overhauled by the contractor if required. (vi)This includes removal of existing gears and ixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. (vii) Supply of electric point machine IRS 220mm stroke , ground connection, extension plate will be done by railways. Inspection RDSO | — | — | — | 11,87,087.4 | |
| — | 300.00 | — | — | ||
| Supply of drill bit of size 9/32""(7.2/7.14mm) twist drill morseshank suitable for making holes in the rails for TWS. Contractor should get the approval of sample from railway Engineer before supply. Note- Compatible for installation of 220mm point m/c for Thick Web Switch. Inspection Consignee | — | — | — | 47,112 | |
| — | 2.00 | — | — | ||
| Supply of heavy duty Rail drilling machine (Electric) with socket and accessories Make- BDS RAIL MAB 915 or similar. (Inspection Consignee) Note- Compatible for installation of 220mm point m/c for Thick Web Switch. | — | — | — | 2,94,052 | |
| — | 50.00 | — | — | ||
| "Supply of Annular Cutter 22*55. Inspection Consignee | — | — | — | 1,52,687 | |
| — | 10.00 | — | — | ||
| "Supply of Annular Cutter 22*30.Inspection Consignee | — | — | — | 16,011.5 | |
| — | 120.00 | — | — | ||
| Supply of point JB fitted with 18 Nos. 1 way ARA PBT terminal block conforming to IRS - S-75/91 with 3 Nos. of 40mm Bore. GI pipe 600 mm long as per DRG No.SGW/MGS/PT4/91 fixed on hard wood plank with U-channel (75 x 40 x 1500) mm for fixing. Inspection Consignee for Point JB, ARA terminal - RDSO | — | — | — | 5,54,402.4 | |
| — | 20.00 | — | — | ||
| Supply of complete ground fittings for point machine,including insulated stretcher B a r Switch extension piece etc. and all other accessories required for installation.- For IRS point machine Spec- IRS-24-90 Turn out- RDSO DRG No- SA-S3261 62 01 Inspection RDSO | — | — | — | 3,45,497.4 | |
| — | 150.00 | — | — | ||
| Dismantling of existing point fitings and installation of already prepared and matched point fitting sets for point machine of IRS 24/90 type with final testing and commissioning from panel as per technical specification including transportation from railway store. -a) Turn out (Facing point layout) | — | — | — | 18,07,834.5 | |
| — | 200.00 | — | — | ||
| Excavation,trenching,earth work and reinstatement of track while track crossisng. | — | — | — | 28,120 | |
| — | 30.00 | — | — | ||
| Laying cable of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender. 2 core to 12 core signalling cable. | — | — | — | 3,49,514.7 | |
| — | 200.00 | — | — | ||
| Digging o u t o f Point J B & i t s cable after opening o f wiring from A RA terminals & its reconnection of conductor in point JB and reinsertion along with back filling of point JB to it in original state. This work is for one point JB. | — | — | — | 1,42,500 | |
| — | 2.00 | — | — | ||
| Supply , installation, testing & commissioning of FAT set up having Industrial Grade PC as per RDSO TAN/STA/E/TAN/3007 version 1.0 dt 02.11.2012 along with 65" Monitor as Operator console with terminal embeded including MF printer, UPS, 1 PC/Laptop. Inspection Consignee(Material should be supplied as per technical specification attached as ANNEXURE 'AA' in tender document.) | — | — | — | 17,95,000 | |
| — | 1.00 | — | — | ||
| Supply and installation of superior control desk Table for monitors as above & their power supply arrangement. Inspection Consignee | — | — | — | 72,846.75 | |
| — | 1.00 | — | — | ||
| Supply and installation of Local Craft terminal/ maintenance console, Intel Core i7 12500 16 GB/ with HDD/ Windows 11 Professional make-HP/Dell or similar. AIl installation materials along to be supplied with the system. Inspection Consignee (Material should be supplied as per technical specification attached as ANNEXURE 'AA' in tender document.) | — | — | — | 71,734.75 | |
| — | 2.00 | — | — | ||
| Supply installation, testing and commissioning of 8 port Gigabit PoE Layer 2 Switch supports 8 nos 10/ 100/ 1000 BASE-T ports, along with 2 Gigabit SFP ports combo ports PoE power support 130 watt or as per site requirement. Make- CISCO/ Juniper or superior. Inspection Consignee | — | — | — | 44,580 | |
| — | 2.00 | — | — | ||
| Supply and installation of 1TB SATA Hard Disk compatiable with item no.-1 as per site requirement. Inspection Consignee | — | — | — | 4,515 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Wifi-6 Mesh router Make- Tp-link Deco M4 or better. Inspection Consignee | — | — | — | 10,000 | |
| — | 1.00 | — | — | ||
| Supply installation, testing and commissioning of Wireless HDMI Receiver and Transmitter Extender Make- Tp-link Deco M4 or better.Inspection Consignee | — | — | — | 10,517 | |
| — | 1.00 | — | — | ||
| Supply of PVC Insulated Aluminium underground Unscreened Power Cable of 2 core X 25 sq. mm as per spec Nos. IRS:S- 63/2014(Rev.4.0) or latest.Inspection Consignee | — | — | — | 1,27,718 | |
| — | 30.00 | — | — | ||
| Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. Nos. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing Nos. SDO/ RDSO/E&B/002 or latest are as under,(a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 Nos. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x6mm to exothermically welded to Earth electrode- 1 Nos.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 Nos.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 Nos. It also includes supply of (i) 35 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.- 10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter.Inspection RITES | — | — | — | 6,26,460 | |
| — | 30.00 | — | — | ||
| Installation of Single Maintenance Free Earth pit a s per RDSO Drawing Nos. SDO / RDSO/ E&B/001 which includes the following,a) Digging /Auguring/Boring o f single earth pit o f 100mm to 125mm dia. t o the depth of approx. 3 meter. b ) Insertion of 3.0 meter electrode and penetrating i t minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. Installation of item above | — | — | — | 1,97,610 | |
| — | 250.00 | — | — | ||
| Supply and laying of 70 sq. mm. PVC insulated flexible tinned electrolytic copper down conductor placed in a metallic/PVC protective covering wherever exposed to human intervention including addles and all accessories etc. as required. Inspection Consignee | — | — | — | 3,40,302.5 | |
| — | 250.00 | — | — | ||
| Supply and laying of 25 x 3 mm. pure electrolytic copper tape through suitable 'Class B' G.I pipe for loop earthing and bonding as per site requirement. Wire Colours shall be decided by engineer-in Charge. Inspection Consignee | — | — | — | 3,19,765 | |
| — | 100.00 | — | — | ||
| Supply of 50 mm x 6 mm Galvanised steel tape for interconnecting the earth pits. Inspection Consignee | — | — | — | 55,800 | |
| — | 100.00 | — | — | ||
| Supply of 25mm x 2 mm bare copper strips or 8mm round solid copper in the equipment room. Inspection Consignee | — | — | — | 1,26,000 | |
| — | 2000.00 | — | — | ||
| Supply of PVC insulated 10 Sq. mm Single core Multi strands copper conductor as per Specification Nos. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in Charge. Inspection Consignee | — | — | — | 2,18,000 | |
| — | 2500.00 | — | — | ||
| Supply of PVC insulated 16 Sq. mm Single core Multistrands copper conductor as per Specification Nos. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in Charge. Inspection Consignee | — | — | — | 3,72,500 | |
| — | 100.00 | — | — | ||
| Supply of PVC insulated 35 Sq. mm Single core Multistrands copper conductor as per Specification Nos. IRS:S-76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in Charge. Inspection Consignee | — | — | — | 25,400 | |
| — | 15.00 | — | — | ||
| Provision of Class C SPD's in common and differential mode for Relay external, Axle Counter, Point machine circuit & at inverter output (for four circuit per IPS) Inspection RITES | — | — | — | 4,59,375 | |
| — | 30.00 | — | — | ||
| "Supply and installation of Class B & C Surgeprotection Device (SPD) -Type I & IIwith Visual Indication and Potential free contact to remote monitoring asper Specification No.RDSO/SPN/165/2023 Ver 4.0 or latestand IEC standard 61643 or latest and IEC 62304-5 or latest for Singlephase 230V AC application withhandling Lightning surges of 10/350microseconds and Switching surges of8/20 microseconds .One Set consistsof 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N)all enclosed in a Box with KEMA orVDE certified as per latest IEC 61643-11-2011 Standard or latest. Class B &C Surge protection device required with Three modules only. Inspection RITES with OEM's GC,TC & WC. | — | — | — | 1,94,151.9 | |
| — | 50.00 | — | — | ||
| Installation of isolated Spark gap as per latest RDSO- TAN version 3.0 technical specification. | — | — | — | 7,54,353.5 | |
| — | 100.00 | — | — | ||
| Exothermic welding in relay room, IPS or any indoor room as per STS/E/TAN/3006 ver 3.1 dt.30.6.2025, | — | — | — | 41,839 | |
| — | 100.00 | — | — | ||
| Exothermic welding for any outdoor Work for earth connection as per STS/E/TAN/3006 ver 3.1 dt.30.06.25 | — | — | — | 34,866 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022__GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
DocSig2026-20.pdf
ATTACHMENT
ACSGCC20221to11.pdf
ATTACHMENT
ECRJPOregardingprocedureforundertakingearthworkdiggingworktrenchingworkinthevivinityofsignallingtelecomandelectricalcables.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .