Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹3.3 Cr+₹22.6 L (7.26%)Rejected-Finance | ₹3.3 Cr+₹22.6 L (7.26%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹3.4 Cr+₹28.5 L (9.16%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹3.4 Cr+₹28.5 L (9.16%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹3.6 Cr+₹48.7 L (15.6%)Rejected-Finance | ₹3.6 Cr+₹48.7 L (15.6%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹3.6 Cr+₹49.4 L (15.9%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹3.6 Cr+₹49.4 L (15.9%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
5 Apr 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
COMPLETION OF INCOMPLETE WORKS FOR PROVN OF OTM ACCN (PH-II) AT BIKANER MIL STN
2022_MES_567443_3
CE BTZ/BKN/TOKEN/16 OF 2022-23
Open Tender
Civil Works
Lump-sum
275 days
Bikaner
As per NIT
10 documents required · 10 mandatory
₹2,000
Garrison Engineer (P) Bikaner
₹3.5 L
Yes
19 Apr 2023
10 Mar 2023
7 Apr 2023
10 Mar 2023
5 Apr 2023
24 Mar 2023
Amount
Sch 'A' Sec-I (Building Work) Note :- This schedule is not prepriced by MES hence the rate indicated as Rs 0.00 under Col 5 (However for guidance only see Annexure-'I'). The contractor need to insert their lump sum price in Col 6 & 7 as worked out by them.
Sch 'A' Sec - I (Part-I) (Building Work)
Provn of block of Night Picket including verandah complete all as specified & shown on drgs (1st block). (ref item No 1 of Annexure-I)
Provn of block of Night Picket including verandah complete all as specified & shown on drgs (2nd block). (ref item No 2 of Annexure-I)
Provn of block of Officers Mess for (for 19 to 28 Officers) including platform , porch and verandah complete all as specified & shown on drg (ref item No 3 and 3a of Annexure-I)
Provn of block of Servant Qtrs 06 Nos single storied complete including verandah all as specified & shown on drgs (ref item No 4 of Annexure-I)
Provn of block of Servant Qtrs 05 Nos double storied including verandah complete all as specified and shown on drgs (ref item No 5 of Annexure-I).
Provn of open car garage for 06 cars including apron complete all as specified and shown on drgs (ref item No 6 of Annexure-I)
Provn of block of Single Accn for JCOs (04 JCOs), double storied including ramp, scooter shed, verandah complete all as specified & shown on drgs (ref item No 7 of Annexure-I)
Provn of block of OR institute including platform and verandah complete all as specified and shown on drawing (ref item No 9 of Annexure-I)
Provn of block of Religious Institute including entrance platform complete all as specified and shown on drg (ref item No 10 of Annexure-I)
Provn of block of MI Room (upto 1000 Men) including ramp, verandah and platform complete all as specified and shown on drg (ref item No 11 of Annexure-I)
Provn of block for 20 cycle cum 10 scooter shed and 01 Garage including Apron complete all as specified and shown on drg (ref item No 12 of Annexure-I)
Provn of block of MT Garages for staff cars ISUZU (02 Nos), Maruty Gypsy/Jeep (09 Nos) & TLR 1000 Ltrs (01 No) (Block of 12 Garages) including Apron complete all as specified and shown on drg (ref item No 13 of Annexure-I)
Provn of block of MT garages for Ly 3 Ton S'man Carvan (02 Nos) TLR 02 Ton 4 WHLD (02 Nos) Ly 2.5 Ton (01 Nos) TLR 1 Ton 500 Ltrs (02 Nos) & TLR 500 Kg (03 Nos) (Block of 10 garages) including apron complete all as specified and shown on drg (ref item No 14 of Annexure-I)
Provn of block of MT garage for LY 3 Ton S'man/ALS (08 Nos) & LY 3 Ton water bouser 3000 Ltrs (01 No) & Motor Cycle (02 Nos) (Block of 09 Garages) including Apron complete all as specified and shown on drg (ref item No 15 of Annexure-I)
Provn of Repair Bay (03 Nos) with 01 inspection pit including rolling shutters, Apron complete all as specified and shown on drg (ref item No 16 of Annexure-I)
Provn of block of MT Store , Storage, Petrol Store & MT drivers stand by & changing room including sanitary Annexe, ramp, verandah and platform complete all as sepcified and shown on drg (ref item No 17 of Annexure-I)
Provn of block of IDSS Modified shelter (For ALS VEH- 05 Nos) including Apron complete all as specified and shown on drg (ref item No 18 of Annexure-I)
Provn of block of IIT Modified shelter (For ALS VEH-02 Nos), including Apron complete all as specified and shown on drg (ref item No 19 of Annexure-I)
Provn of coal and coke yard (for 10 ton coal) including ramp complete all as specified and shown on drg (ref item No 20 of Annexure-I)
Provn of static water tank (capacity 50 KL) brick maonary construction complete all as spcified and shown on drg (1st block) (ref item No 21 of Annexure-I)
Provn of static water tank (capacity 50 KL) brick maonary construction complete all as spcified and shown on drg (2nd block) (ref item No 22 of Annexure-I)
Provn of Ramp (Double type) type complete all as specified and shown on drg (1st block) (ref item No 23 of Annexure-I)
Provn of Ramp (Double type) type complete all as specified and shown on drg (2nd block) (ref item No 24 of Annexure-I)
Provn of washing platform ( for 01 No 'B' Veh) complete all as specified and shown on drg (1st block) (ref item No 25 of Annexure-I)
Provn of washing platform ( for 01 No 'B' Veh) complete all as specified and shown on drg (2nd block) (ref item No 26 of Annexure-I)
Provn of washing platform ( for 01 No 'B' Veh) complete all as specified and shown on drg (3rd block) (ref item No 27 of Annexure-I)
Provn of parade ground of size 73 metre x 73 metre complete all as specified and shown on drg (ref item No 28 of Annexure-I)
Provn of Football Ground complete all specified and shown on drg (ref item No 29 of Annexure-I)
Provn of Basketball court complete all specified and shown on drg (ref item No 30 of Annexure-I)
Provn of Volley ball court complete all specified and shown on drg (ref item No 31 of Annexure-I)
Blank
Blank
Constructuon of Ornamental steel Gate (typical Steel gate) 7.5 metre wide including excavation, RCC work, form work etc complete all as specified and shown on drawings (3rd block) (ref item No 34 of Annexure-I)
Constructuon of Ornamental steel Gate (typical Steel gate) 7.5 metre wide including excavation, RCC work, form work etc complete all as specified and shown on drawings (4th block) (ref item No 35 of Annexure-I)
Blank
Provn of Mild Steel Gate 5.5 m wide, 3.00 metre height RCC pillar and shutters for 2.4 metre height complete all as specified and shownb on drg (2nd block) (ref item No 37 of Annexure-I)
Blank
Provn of Mild Steel Gate 5.5 m wide, 3.00 metre height RCC pillar and shutters for 2.4 metre height complete all as specified and shownb on drg (4rth block) (ref item No 39 of Annexure-I)
Construction of block masonary septic tank for 50 user complete all as specified and shown on drawings (ref item No 40 of Annexure-I)
Construction of Brick Masonary Soakage well 2.4 metre dia x 6 metre deep complete all as sepcified and shown on drawings (ref item No 41 and 41a of Annexure-I)
Provn of Environment pond 50000 Gln capcity complete all as specified and shown on drgs (ref item No 42 of Annexure-I)
Notes for Srl item No 2.01 to 2.41 :- 1. The cost to be quoted under clumn 6 against each item above is the cost of balance work. 2. The balance left over works in these buildings are to be completed as per drawings and specifications including deviations etc as listed in Annexure 'IV & V'. The approximate details of the completed / balance works against Srl item No 2.01 to 2.41 above is given in Annexure-'I' indicating the estimated cost of Balance work at par SSR 2010 rates for guidance only. The tentative list of defects is given in Annexture 'II'. However the tenderer should visit site of work to ascertain the exact quantum of balance work for all items mentioned above alongwith deviation & defects etc and quote his rates accordingly.
Subtotal
Sch 'A' Sec - II (Part-I), (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION)
Point wiring complete with 1.5 Sq mm (nominal area) PVC insulated FRLS, un-sheathed and multi core copper conductor cable (ISI marked with colour code) in and including PVC concealed conduit (medium quantity, ISI marked) and conduit fittings for one light point/fan point/ exhaust fan point/air circulator fan point/ independent 5 Amp multi purpose switch socket/bell/ buzzer/ engagement light controlled by one switch/bell push/switch socket combination including PVC insulated 1.5 Sqmm single core copper earth wire FRLS (ISI Marked) to common earth and connected to earth dolly and including pressed steel powder coated sunken box of suitable size covered with & including 3 mm thick bakelite laminated hylem sheet top cover etc, complete all as specified. (Note :-Switch and socket shall be measured and paid separately)
All as per srl item No.4.01 here-in-before but with 1.5 sqmm (nominal area) PVC insulated stranded copper conductor cable unsheathed ISI marked controlled by two, 2 way switches complete all as specified. (Note :-Switch shall be measured and paid separately)
Point wiring complete with 2.5 Sqmmm 1100 volt (nominal area) PVC insulated FRLS, unsheathed and stranded copper conductor cable (ISI Marked) in and including 20 dia PVC concealed conduit (medium quality, ISI marked) and conduit fitting for one 6 Pin 15 Amp multipurpose switch socket outlet combination including PVC insulated 1.5 Sqmm single core copper earth wire FRLS (ISI Marked) to common earth and connected to earth dolly and including Pressed steel powder coated sunken box 1.6mm thick of suitable size and covered with and including 3mm thick backlite laminated hylem sheet top cover etc complete all as specified. (Note :-Switch and socket shall be measured and paid separately)
Point wiring complete with 1.5 Sq mm (nominal area) PVC insulated FRLS, un-sheathed and multi core copper conductor cable (ISI marked with colour code) in and including PVC concealed conduit (medium quantity, ISI marked) and conduit fittings for one light point/fan point/ exhaust fan point/air circulator fan point/ independent 5 Amp multi purpose switch socket/bell/ buzzer/ engagement light controlled by one switch/bell push/switch socket combination including PVC insulated 1.5 Sqmm single core copper earth wire FRLS (ISI Marked) to common earth and connected to earth dolly complete all as specified. (Note :- Modular switch, socket, inner/outer plate and sunken box shall be measured and paid separately)
Point wiring complete with 2.5 Sqmmm 1100 volt (nominal area) PVC insulated FRLS, unsheathed and stranded copper conductor cable (ISI Marked) in and including 20 dia PVC concealed conduit (medium quality, ISI marked) and conduit fitting for one 6 Pin 15 Amp multipurpose switch socket outlet combination including PVC insulated 1.5 Sqmm single core copper earth wire FRLS (ISI Marked) to common earth and connected to earth dolly complete all as specified. (Note :- Modular switch, socket, inner/outer plate and sunken box shall be measured and paid separately)
Fluorescent tube light fitting suitable for 1 X 28 Watt T5 type energy efficient complete ( excluding Fluorescent lamp) for wall mounting / hanging from ceiling (cable and conduit only for hanging of fitting shall be measured and paid for separately ) Make Cat Part No T5 GP 28 EB of Crompton Greaves, Cat Part No TMS 122/128 HF of Phillips/ Bajaj. (Note : Fluorescent lamp 28 watt will be issued under Sch 'B' free for fixing only)
CFL fitting decorative wall mounted bracket type complete for PL/CFL type including PL/CFL lamp Cat Part No. FTG11/109+1xPL-S9W lamp of Phillps or equivalent Crompton Greaves/equivalent model of Bajaj.
Supply and fixing energy efficient LED wall mounted street light fitting of 25W pressure die cast aluminium housing/body, heat resistant, clear toughened glass, better optics for uniform distribution street/roadway luminaries, with driver, including electric connection with suitable size of wire from ceiling rose to street fitting, fixing the light fitting with and including bracket made out of GI tubing light grade 25mm dia or as per manufacturer recommendation, 1.2 meter long bend to shape at 120 degree angle at half mtr bottom including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specification, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy should be minimum 110 Lumen per watt. (b) Input voltage range : 140 to 270 volt. (c) Temp operating range : Minus 10 degree Celsius to Plus 50 degree Celsius (d) Power factor Minimum 0.95 (e) THD : Max 10% (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP-65 (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaries. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage (inbuilt + extended) (m) Lens – High Efficiency wide angle lens (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 Hrs daily).
MCB 'C' Curve type SP with over load and short circuit protection , 240 volts, AC, 09 KA, 5 to 30 Amps capacity complete all as specified.
MCB 'C' Curve type SPN with over load and short circuit protection , 240 volts, AC, 09 KA, 5 to 40 amps capacity complete all as specified.
MCB 'C' Curve type SPN with over load and short circuit protection , 240 volts, AC, 09 KA, 40 to 60 Amps capacity complete all as specified.
MCB 'C' Curve type SP with overloaded short circuit protection, 240 volts, 40 - 60 amps rupturing capacity 9 KA complete all as specified.
Connector PVC, 3 terminals, 250 volts, 5/6 Amps capacity two way complete all as specified.
M & L for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of GI bolts/nuts/ washers, protected by 20 mm bore GI light grade pipe from earth plate and upto 3 m along pole fixed with 2 clamps made from mild steel flat iron 25x3 mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of charcoal 300mm and common salt 15 cm thick all around. 20mm dia GI medium grade pipe watering and including funnel, wire mesh, CI cover & frame, PCC (1:3:6) C-1 type (using 20 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No.3 of SSR Part-I and connected to earthing point and testing on completion. (Note:- PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner)
Blanking plate of plastic (suitable for distribution board).
Suspended pendent type fancy type light fitting with CFL lamp 1x11 W including suitable size and length of fancy cord single phase 3 core including fancy type white enameled conceal shed complete all as specified.
Mild steel box flush mounted 100 mm x 100 mm x 100 mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection complete all as specified.
CFL fitting mirror light type complete for PL/CFL type including PL/CFL lamp. Cat Part No FMC 200/111 for 1xPL-S 11 W lamp of Phillips, Cat Part No TLN 11 W-1x 11W CFL of Crompton Greaves.
Wiring with twin core PVC insulated sheathed cable with copper conductor having single strand of 0.6 mm dia for telephone wiring from terminal box to telephone socket complete all as shown in drgs and directed. (Note:- PVC conduit and conduit accessories shall be measured and paid separately).
Supply and fixing ceiling fan 1200mm sweep with fan regulator, ISI marked including all fitting such as down road, blades, canopy etc
Subtotal
Sch 'A' Sec - III (Part-I), (INTERNAL WATER SUPPLY)
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY)
CP connection pipe with CP nuts and washers 45 cm long suitable for 15 mm bore pipe one for each side of PVC connection and fixed to iron pipe for making flexible connection to WHB or flushing cisterns etc complete all as specified
PVC connection pipe with CP nuts and washers 45 cm long suitable for 15 mm bore pipe one for each side of PVC connection and fixed to iron pipe for making flexible connection to WHB or flushing cisterns etc complete all as specified
Shower rose cast brass chromium plated fancy 50 mm dia with swivel joints screwed suitable for 15 mm bore GI pipe and fixed complete all as specified
Stop valve fancy type chromium plated conncealed type with long shank screwed down high pressure with capston head screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore of pipe complete all as specified
Bib tap suitable for 15 mm bore pipe, fancy type chromium plated long body with crutch or butterfly handle, screwed down both ends screwed for iron pipe or for unions and fixed, complete all as specified and shown on drawings
Chromium plated, fnacy type, Hot and cold centre hole, basin mixer, screwed down, high pressure with crutch handle screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore of pipe complete all as specified and shown on drawings
Stop valve , cast copper alloy chromium plated, fancy type suitable for 15 mm bore pipe, high pressure with crutch handle screwed down, both ends crewed for iron pipe or for unions and fixed complete all as specified and shown on drawings
Pillar tap, cast copper alloy chromium plated, fancy type suitable for 15 mm bore pipe, high pressure with crutch handle screwed down, both ends screwed for iron pipe or for unions and fixed complete all as specified and shown on drawings
Spreader for urinal, cast copper alloy chromium plated, fancy type suitable for 15 mm bore pipe, high pressure with crutch handle screwed down, both ends screwed for iron pipe or for unions and fixed complete all as specified and shown on drawings
Subtotal
Sch 'A' Sec - IV (SEWAGE DISPOSAL)
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL" as listed in Schedule ‘A’ Section - IV
Sch 'A' Sec - V (Part-I) (ROAD WORK)
Lump sum price worked out by the tenderer for “ROAD WORK" as listed in Schedule ‘A’ Section - V (Part-I)
Sch 'A' Sec - V (Part-II) (ROAD WORK)
Contineous Jodhpur stone slab edging 7.50 cm to 10 cm thick, 30 to 35 cm wide and 30 to 45 cm long, each stone slab self faced on both the vertical sides, the edges slightly true and square on the top edge, hammer dressed for the full thickness so that drepression from a straight edge hold against the surfaces shall not exceed 20 cm betwen two joints including necessary earth work, embedding to depth as required and tamping around edging and removal of surplus soil to a distance not exceeding 50 mtr and depositied as directed complete, all as specified. Note :- (i) The stone slab shall be laid butting to each other in such a way that thickness of edging is equal to thickness of stone slab and depth of edging is equal to width of stone slabs (ii) The stone slabs under srl item No 1 shall be obtained from "Chitter quarry" at Jodhpur (iii) Each side of road shall be measured paid for separately
S&F cat eyes, 100 x 100 x 18.5 mm size dynamically designed very high impact strength and fitted with 02 nos highly reflective complete all as specified and directed
S&F in delineator made of MS pipe 2" dia 16 grade 3' long using HIP grade retro reflective tape in four colour red, white yellow and green strips 2" each complete' all as specified and directed by Engineer-in-charge
M&L for painting lines on road with hot applied retroreflective thermoplastic road marking. paint conforming to MORTH mechanically applied to form 3 mm thick film on road, including cleaning the road surface to make it dust free before application of paint complete
Subtotal
Sch 'A' Sec - VI (INTERLOCKING PATH)
Lump sum price worked out by the tenderer for “INTERLOCKING PATH" as listed in Schedule ‘A’ Section - VI
Sch 'A' Sec - VII (RAIN WATER HARVESTING)
Lump sum price worked out by the tenderer for “RAIN WATER HARVESTING" as listed in Schedule ‘A’ Section - VII
Sch 'A' Sec - VIII (FENCING/COMPOUND WALL)
Lump sum price worked out by the tenderer for “FENCING/COMPOUND WALL" as listed in Schedule ‘A’ Section - VIII
Sch 'A' Sec - IX (Part-I), (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (EXTERNAL WATER SUPPLY)
Valve pit of internal size 90 x 90 x 125 cm of brick masonry including necessary excavation and earth work (in soft loose soil ) . PCC coping MS angle iron frame with angle iron of size 40 x 40 x 6mm and cover of MS sheet 3mm thick with handle & locking arrangement plastering etc complete all as specified and shown in drg.
Subtotal
Sch 'A' Sec - X (Part-I), (EXTERNAL ELECTRIFICATION WORK)
Lump sum price worked out by the tenderer for "EXTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Section - X (Part-I)
Sch 'A' Sec - X (Part-II), (EXTERNAL ELECTRIFICATION WORK)
LT cable XLPE cable insulated PVC sheathed, heavy duty armoured with stranded aluminium conductors, 1100 volts grade with aluminium conductor having cross sectional area 25 Sqmm x 4 core laid in trenches /ducts/through pipes/in floor/along with poles etc including commissioning, testing complete all as specified .
LT cable XLPE cable insulated PVC sheathed, heavy duty armoured with stranded aluminium conductor 1100 volts grade with aluminium conductor having cross sectional area 120 Sqmm x 3.5 Core, laid in trenches /ducts/through pipes/in floor/along with poles etc. including commissioning, testing complete all as specified .
LT cable XLPE cable insulated PVC sheathed, heavy duty armoured with stranded aluminium conductor 1100 volts grade with aluminium conductor having cross sectional area 10 Sqmm x 2 Core, laid in trenches /ducts/through pipes/in floor/along with poles etc. including commissioning, testing complete all as specified and directed.
LT cable XLPE cable insulated PVC sheathed, heavy duty armoured with stranded aluminium conductor 1100 volts grade with aluminium conductor having cross sectional area 6 Sqmm x 2 Core, laid in trenches /ducts/through pipes/in floor/along with poles etc including commissioning, testing complete all as specified .
Local tibba sand cushioning and cover for underground protection of cable and punning, 8cm before laying of cable and 15cm after laying of cable complete all as specified & directed. Note :- (i) Approval local tibba sand after removal of vegetation, grass and other deleterious substances shall be used for sand cushioning and cover. (ii) For the purpose of payments only punned thickness shall be measured.)
Protection to cable with one layer of bricks sub class 'B' (old size) laid flat across the cable complete all as specified and as directed.
Supply and fixing junction box of size 200mmx 160mmx 110mm or any other higher size (pole mounted) and should be insulated and made out of polycarbonate with glass fiber re-inforced material having IP-65 protection in accordance with IEC-60259, fixing with and including SS 304 clamp of size 25x3mm including suitable size of nuts bolts and washers complete comprising of the Note following and as directed :- Note (a) Junction Box must meet the provision laid down in IEC 60998-1, 60695-22, 60670-22 to 5 and color according to RAL – 9011/7035/7035. (b) The manufacture of junction box shall submit a copy of IEC certificate. (c) Junction box shall be fire retardant and self extinguishing in accordance with IEC – 60695-2 to 11, DIN VDE 0304 part – 3 UL-94 V- 2 flammability standard. It should be tested at glow were test for 960oC . (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK08. (e) Internally embedded gasket of polyurethane/extruded silicon gasket. (f) Junction box shall 4 pole complete with single pole MCB ”C” curve of 6 amp, rating.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant, clear toughened glass, better optics for uniform distribution street/roadway luminaries, with driver, including electric connection with suitable size of wire from junction box to street fitting, fixing the light fitting with and including bracket made out of GI tubing light grade 32mm dia, 1.2 meter long bend to shape at 120 degree angle at half mtr bottom including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specification, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy should be minimum 110 Lumen per watt. (b) Input voltage range : 140 to 270 volt. (c) Temp operating range : Minus 10 degree Celsius to Plus 50 degree Celsius (d) Power factor Minimum 0.95 (e) THD : Max 10% (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP-65 (h) IK rating : Min,ium IK07 (j) Built in potted LED Driver of the make as of the luminaries. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage (inbuilt + extended) (m) Lens – High Efficiency wide angle lens (n) BIS Approved fixtures and driver (o) Rated lfie time : 50000 burning hrs (Average 10 to 12 Hrs daily).
Supply and fixing LED post top light fitting of 25W decorative design, glare free and better uniformity complete fitting all with accessories and LED lamp, fixing on and including 50mm dia GI pipe light grade of length 2.5 mtr embedded in PCC block of size 0.3x0.3x0.5m, made with PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate, including making connection with suitable size of wire, complete fitting with all accessories and following specification, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy should be minimum 110 Lumen per watt. (b) Input voltage range : 140 to 270 volt. (c) Temp operating range : Minus 10 degree Celsius to Plus 50 degree Celsius (d) Power factor Minimum 0.95 (e) THD : Max 10% (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP-65 (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaries. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage (inbuilt + extended) (m) Lens – High Efficiency wide angle lens (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 Hrs daily).
Supply and fixing LED post top light fitting of 70W decorative design, glare free and better uniformity complete fitting all with accessories and LED lamp, fixing on and including 50mm dia GI pipe light grade of length 2.5 mtr embedded in PCC block of size 0.3x0.3x0.5m, made with PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate, including making connection with suitable size of wire, complete fitting with all accessories and following specification, complete all as specified and directed by Engineer-in-Charge:- (a) Lumen system efficacy should be minimum 110 Lumen per watt. (b) Input voltage range : 140 to 270 volt. (c) Temp operating range : Minus 10 degree Celsius to Plus 50 degree Celsius (d) Power factor Minimum 0.95 (e) THD : Max 10% (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP-65 (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaries. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage (inbuilt + extended) (m) Lens – High Efficiency wide angle lens (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 Hrs daily).
Supply and fixing time switches astro type (having longitude and latitude of single phase of 20A rating with contracted fitted inside steel enclosure.
Supply and fixing energy efficient LED Flood Light of 150W, pressure die cast aluminium housing/body, heat resistant, clear toughened glass, better optics for uniform distribution street/roadway luminaries, with driver, including electric connection, complete fitting with all accessories and following specification, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy should be minimum 110 Lumen per watt. (b) Input voltage range : 140 to 270 volt. (c) Temp operating range : Minus 10 degree Celsius to Plus 50 degree Celsius (d) Power factor Minimum 0.95 (e) THD : Max 10% (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP-65 (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaries. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage (inbuilt + extended) (m) Lens – High Efficiency wide angle lens (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 Hrs daily).
Fixing only steel tubular pole type 410 SP-31 (9 mtr long) confirm to IS-2713, factory painted with bituminous paint internally through out and externally upto fixing depth and remaining protion shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete with cost iron base plate, final taper plug, bolts nuts and screwed mounting single parabolic bracket assembly, bent to shape and not less than 2.5 mtr is length to adopt street lights fitting including painting of poles (Two coats) with alternative black and white strips upto 1.5 mtr height from top edge of coping complete including numbering of poles complete all as specified. Note: (i) Steel tubular pole with base plate will be issued under Sch 'B' free for fixing. (ii) Final taper plug , bolts, nuts and screwed mounting single parabolic bracket including external painting shall be deemed to be included in unit rate. (iii) Excavation, earth work and PCC shall be measured & paid separately).
Earthing of poles complete all as per electric plate No.3 of SSR Part-I with galvanised cast iron earth place electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.50 mtr below normal ground level covered with charcoal dust & salt 15cm around the electrode connected to galvanised earth lead wire 4mm dia with GI nuts , bolts and washers and check nuts required size, 15mm dia GI pipe light grade for protection of earth wire lead form earth plate electrode upto 3 mtrs 20mm dia GI pipes light grade for watering complete with funnel and PCC (1:3:6) chamber and 2:3 mm thick unpolished stone slab pit cover incl earth wire complete all as specified and shown in electrical plate No.3 ( Note :- Necessary earth work PCC pit cover, protection of GI pipe of size 20 mm dia light grade, test point etc shall be inclusive in unit rate.)
Subtotal
Sch 'A' Sec - XII (AREA DRAINAGE)
Lump sum price worked out by the tenderer for “AREA DRAINAGE" as listed in Schedule ‘A’ Section - XII
Sch 'A' Sec - XIII (Part-I), (HUME PIPE CULVERT)
Lump sum price worked out by the tenderer for "HUME PIPE CULVERT" as listed in Schedule ‘A’ Section - XIII (Part-I)
Sch 'A' Sec - XIII (Part-II), (HUME PIPE CULVERT)
PCC 1:3:6 type C-2 using 20 mm graded stone aggregate as in encasing of pipe dia 600 mm complete surrounding of pipe complete all as specified and directed
PCC 1:3:6 type C-2 using 20 mm graded stone aggregate as in encasing of pipe dia 450 mm complete surrounding of pipe complete all as specified and directed
Subtotal
Sch 'A' Sec - XIV (Part-I), (WINTER APPLIANCES)
Lump sum price worked out by the tenderer for "WINTER APPLIANCES" as listed in Schedule ‘A’ Section - XIV (Part-I)
Sch 'A' Sec - XIV (Part-II), (WINTER APPLIANCES)
Fixing only solar water heater system storage type having capacity 100 Litres per day including solar panel collector, absorber and other required accessories, insulated stainless steel storage tank 100 ltrs capacity (to be placed on roof at a height of 3.00 mtr (approximate) with aluminium cladding , angle iron structure, cold water tank capacity 300 litre (HDPE Double layer) with inter connection between tank and solar panel and necessary masonry work, concrete work, foundation including electric back up 2.0 KW and electric panel with MCB and other safety such as thermostat, relay etc complete all as per manufacturer's instructions and as directed by Engineer -in -Charge. (Note :- Solar water heater shall be issued under Sch 'B' free for fixing only)
Staging for water tank with angle iron 75mmx75mmx10mm thick including welding and preparation of steel and iron surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Rotation moulded polyethylene water storage tank, three layered, white colour of capacity 200 liters (cylindrical vertical with closed top) for solar water heating system hoisted and fixed in position complete all as specified and directed.
Subtotal
Sch 'A' Sec - XV (SUMMER APPLIANCES )
Supply, installation and testing of Refrigerator single phase of capacity 310 litres complete including fixing of automatic boost buck transformer of required capacity including electric connection through buck / boost transformer complete all as specified and directed by Engineer- in - charge.
Supply, installation and testing of Refrigerator single phase of capacity 180 litres including fixing of automatic boost buck transformer of required capacity including electric connection through buck/boost transformer complete all as specified and directed by Engineer- in - Charge.
Fixing only storage type water cooler electric driven single phase 240 volts, 50HZ having storage capacity 80 Ltrs and normal cooling capacity 40 ltrs per hour with necessary inlet connection with HDPE/flexible pipe both ends CP brass union for GI pipe ball valves brass etc comlete including electric connection complete all as specified directed. Note :- Water cooler electric driven single phase shall be issued under Sch 'B' free for fixing only
Fixing only Desert cooler having nominal air flow capacity 3000 cum per hour single phase, 240 volts, 50HZ, with necessary inlet connection with HDPE/flexible pipe both ends CP brass union for GI pipe and ball valves brass complete including electric connection and including angle iron frame of size 25mm x25mmx 3mm to be grouted in wall including painting in stand complete all as specified and directed by Engineer-in-charge. Note:- (i) Necessary inlet connection with HDPE/flexible pipe both ends CP brass union for GI pipe and ball valves brass complete including electric connection and including angle iron frame of size 25mm x25mmx 3mm to be groutd in wall including painting in stand shall be provided by contractor and rates of these items are included in this item and nothing extra shall be paid on this item and nothing extra shall be paid on this account. (ii) Desert cooler will be issued under Sch 'B' free for fixing only).
Supply and fixing Desert Cooler having nominal air flow capacity 3000 Cum/hrs sigle phase, 240 Volt, 50 Hz with necessary inlet connection with HDPE/ flexible pipe both ends CP brass union for GI pipe and ball valves brass complete including electric connection and incl angle iron frame of size 25x25x3mm to be grouted in wall including painting in stand complete all as spcified and directed by Engr-in-charge
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 1 KVA complete. Make :- Brend Ford/Vinitec/AE
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 2 KVA complete. Make :- Brend Ford/Vinitec/AE
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 5 KVA. Make :- Brend Ford/Vintec/AE
Fixing only wall split units indoor/outdoor complete with cordless remote control units and with in built air ionizer an plasma filter for better indoor air quality with minimum three star and rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed Note :- AC split type 1.5 ton 3 star will be issued under Sch 'B' free for fixing only
Subtotal
Sch 'A' Sec - XVI (SITE CLEARANCE AND EARTH WORK)
Lump sum price worked out by the tenderer for “SITE CLEARANCE AND EARTH WORK" as listed in Schedule ‘A’ Section - XVI
M/s Khanna Enterprises
Jasraj & Company
M/s Madan Gopal Vyas
M/s Arihant Builders
M/S BUDHRAM BISHNOI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .