| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | ₹28.1 L Quoted ₹29.5 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹29.8 L+₹26,385 (0.89%)Rejected-Finance | ₹29.8 L+₹26,385 (0.89%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹33.9 L+₹4.4 L (14.9%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹33.9 L+₹4.4 L (14.9%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹34.6 L+₹5.1 L (17.3%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹34.6 L+₹5.1 L (17.3%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹34.7 L+₹5.2 L (17.5%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹34.7 L+₹5.2 L (17.5%) | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹89,580
Closing Date
10 Dec 2024, 6:00 pmClosed
GE (AF) UDHAMPUR
GE (AF) STATION UDHAMPUR
REPAIR/ MAINT OF LT PANEL, BUSBAR, CABLE AND JOINT KIT, REPAIRING OF LT CABLE, REPLACEMENT OF MCCBs, RELAY, ACB, FEEDER PILLAR AND CERTAIN ALLIED WORKS AT 39 WING AF STN UDHAMPUR
2024_MES_683449_1
GEAFU-55/2024-25
Open Tender
Civil Works
Works
270 days
GE (AF) STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹89,580
10 Jan 2025
12 Nov 2024
12 Dec 2024
12 Nov 2024
10 Dec 2024
26 Nov 2024
12 Nov 2024 - 19 Nov 2024
Amount
M & L for repair to APFC panel of any make and capacity located at various location of 39 Wing AF Station Udhampur including taking down to control wiring/relay/contactor/CT/PT/capacitor bank, cleaning with air blower & replacement to non functional part etc and reassembling, testing, commissioning, Re-programming of relay & increasing or decreasing of steps all including of fixing additional contactor, fuse unit, MCCB & Control / power wiring etc shall be included in quoted rates. Note :- (i) Spare items shall be measured and paid separately. (ii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(iv) Unit rates quoted by tenderers shall deem to include for Nuts & bolts, washers, lugs, thimble, wires etc alongwithwelding job if required and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only in repair cylindrical heavy duty capicitor 440/415 (V) (AC) 3 phase, 50 Hz for APFC panel complete all as specified and directed by engineer in charge KVAR rating Make : havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS
Supply only in replacement of pilot lights direct integral LED of 230 volts ,colour red complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of pilot lights direct integral LED of 230 volts ,colour green complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of non illuminated pushbutton turn to release of dia of head 40 mm ,type of contact NC colour red complete all as specified and directed by Engr-in-Charge.
Supply only in repair standard extended rotary handle for 100/160/250 Amp complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of three phase voltmeter CI0.5 as per IEC 61010-1,50 Hz AC,LED indicators complete . Make: : Schneider cat part No. METSEDDM3210 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of three phase Ammeter CI0.5 as per IEC 61010-1,50 Hz AC,LED indicators complete . Make: : Schneider cat part No. METSEDDM3110 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of MPP heavy duty can type, power capacitors 3 phase 12.5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric, /ABB/ Legrand/ C&S
Supply only in replacement of MPP heavy duty can type , power capacitors 3 phase 5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engineer-in Charge make : Schneider -electric,cat part no.MEHVCHDY050A44 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed.
Supply only in replacement of capacitor duty contactor (AC coil) ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 12.5 KVAR with auxilliary contacts (1 NO+2NC) complete all as specified and directed by Engr-in-Charge Make : Schneider cat part No. LC1DFK* or its equivalent Legrand/ ABB/ C&S.
Disconnecting and taking down old unserviceable ACB of any description and capacity and supply and fix Air circuit breaker 4 Pole, 415V, Fixed Type circuit breaker microprocessor based with ET2B trip unit of capacity 800 Amps breaking capacity 50 KA as per Conforms to IEC/EN : 60947-2, IS-13947-2, ICS=100% of ICU, Icw=50 kA 1 sec, Ui = 1000V ,Uimp=12KV, Frequency = 50/60 Hz, cat B complete all as specified and directed by Engineer-in Charge.make :Schneider cat part No.SPS08F4PMF2B, Havells/L&T/Legrand etc or equivalent as approved by GE
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to galvanisediron or steel strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance 5 Ohm is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance 5 Ohm is not obtained the earthing will be redone at no extra cost.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
Supply and laying DWC HDPE pipe 40 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply and laying DWC HDPE pipe 80 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 80mm including all fittings complete all as specified and directed.
M&L in repair Aluminium Lugs of size 95 sqmm complete all as per specified and directed.
M&L in repair Aluminium Lugs of size 120 sqmm complete all as per specified and directed.
M&L in repair Aluminium Lugs of size 185 sqmm complete all as per specified and directed.
Repair/maint and overhauling of L.T.Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp meter, phase indicator LED lamp,Change over switch of any capacity ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of partswith replacement of unsv nuts, bolts, thimbles, gasket etc as per site requirement including denting if requirement complete testing all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring will be measured and paid seperately under respective item of Sch 'A'. (b) Denting, welding, replacement of unsv hinges, locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint alongwith reassembling, testing, commissioning etc shall be deemed included into the quoted rate. (c) civil work for grouting of panel shall be deemed to be included in the quoted rate.
Supply only MCB TPN, 'C' series capacity 32 Amps, 415V, 50 c/s 16 KA . Make : Legrand / Schnieder / L&T
Supply only in repair MCB SPN capacity 32 amp, 'C' series-02 Nos Make : Legrand / Schnieder / L&T
Supply only in repair Set of indicating lamp LED type-01 Set.
Supply only in repair Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 25 mm x 3 mm
Supply only in repair Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 50 mm x 6 mm
Supply only in repair Current transformer of suitable size as per existing
Supply only in repair Copper wiring 1.5 Sqmm as per existing size
M&L for repair to existing LT panels broken front and rear doors of by using suitable hinges & door lock with necessary welding work all as specified and as directed by Engineer-in-charge.
M & L for PCC 1:3:6 type C2 with using 40 mm graded aggregate as in foundation of broken transformer plinth , panel, pole, bus bar etc with necessary form work complete as specified and directed by Engr-in-Charge.
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for broken transformer plinth , panel, pole, bus bar etc including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for bricks works with sub class B bricks straight or curved on plan exc 6m means radius built in cement mortar 1: 6 etc complete as specified and directed by Engr-in-Charge.
M& L for 10 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
S & F in repair street light bracket made out of 40/50 mm dia GI heavy grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers complete all as specified and directed by Engr-in-Charge.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates).
95 Sqmm, 3.5 Core
120 Sqmm, 3.5 Core
10 Sqmm, 4 core cable
25 Sqmm, 3½ core cable
35 Sqmm, 3½ core cable
150 Sqmm, 3½ core cable
185 Sqmm, 3½ core cable
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with appropriate layer before and after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Repair and replacement of GI tube light grade of bore 50 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing complete all as specified and directed by Engr in charge
Repair and replacement of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing complete all as specified and directed by Engr in charge
Repair and replacement of GI tube light grade of bore 150 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing complete all as specified and directed by Engr in charge
M & L for cutting of Road and Concrete surfaces upto 300 mm depth and 500 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
M&L for in replacement of Varlogic APFC relays- classic range RT6,6 step ,440 volts,5 Amps Make : Schneider cat part No. 51207 or equivalent approved model in Legrand/ C&S complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of Varlogic APFC relays- classic range RT8, 6 step ,440 volts,5 Amps Make : Schneider cat part No. 51209 or equivalent approved model in Legrand/ C&S complete all as specified and directed by Engr-in-Charge.
S & F in repair Procom DGC-6D controller for electronic control panel of existing make/type/rating/model for AMF panel boards etc complete all as directed by Engr-in-Charge.
S & F in repair ET-8000 controller for electronic control panel of existing make/type/rating/model for AMF panel boards complete all as specified and directed.
Supply and fix 3/4 pole power contactor MCX 43 (2NO and 2NC) of capacity 250 Amps ,AC 415 Volts, 50 Hz for panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply & fix 3/4 pole power contactor MCX 32 (2NO and 2NC), of capacity 200 Amps ,AC 415 Volts, 50 Hz for panel including testing or as per existing make/type/rating/model for AMF panel boards etcand taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply & fix 3/4 pole power contactor MCE 15 N, of capacity 160 amps ,AC 415 Volts, 50 Hz for panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceablecomplete all as directed by Engr-in-Charge.
Automatic street light switch "NATURE SWITCH" for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch ) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compund conforming to IP-54. The contactor, MCB and circuit wiring 16 sqmm copper shall be suitable enough to take load of 25 KW single phase load /8 KW load equally distributed over 3-phase (8 KW/phase), contactor rating 40 Amps(2 pole)and 40 amps 4 pole and MCB (single pole) rating 63 amps (SP-3 Nos) complete including sheet metal enclosure with stand made of suitable size angle iron and grouting of enclosure using cement concrete 1:2:4 type B-I (using 20mm graded crushed stone aggregate) all as specified and directed by Engineer-in-Charge including taking down old. Make :- Healer and Model No. SWADEEP-02EC25kW 3 PHASE or its equivalent make .
Laying under ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B' or the existing overground and laying cable along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs and making good all as specified and as directed by Engr-in-Charge. Note :- (i) Execavation / Returning / Filling / cable protection and sand cushioning shall be measured and paid separately. (ii) Quoted rate shall be inclusive of cutting cable/jointing of cable, provision of thimbles, lugs, cable gland for connection of cable IN / OUT from Panels/Feeder Piller Boxes/Bus bar as per Site requirement. (iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. (iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store.
Supply and fix 250 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=150 Lm/Watt, 5700 k luminaire energy saving including driver and surge protection system, environmental friendly long life with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed
M&L for replacement of Copper Strip 20x3.15mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground, complete all as specified and as directed.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Supply and fix 150 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k engergy saving including driver and surge protection system, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed
Supply and fix off LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed.
Supply and fix off LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed.
M&L for cutting the existing cable from loop near the panel and making end termination with aluminium lugs of suitable size without jointing kit with cable glands suitable for LT U/G cable of following sizes:
120 x 3.5 to 185 x 3.5 sqmm .
50 x 3.5 to 95 x 3.5 sqmm .
16 x 3.5 to 50 x 3.5 sqmm
Disconnecting and taking down old unserviceable of bus bar chamber and supply and fixing of Weather proof outdoor bus bar chamber, made out of 3.15 mm thick CRCA sheet comprising 4 Nos Copper strips each of 400 Amps, powder coated with 7 tank process60 cm long duly insulated mounted on insulators complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge .as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 400 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 1 Set Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (c) C.T's of suitable ratio (Set of three) (d) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. (e) Incoming:- MCCB 250 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand (f) Outgoing:-(i) MCCB 160amps ,25 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand (ii) MCCB 100 amps , 16 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 03 nos Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE.
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated ,TPN copper busbars of rating 250 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on corrosive SMC insulator 250 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT of suitable ratio (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE.
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick MS sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 600 Amp Cap of length not less than 60 cm and suitable size of strip for 3 phase and neutral with colour code heat shrinkable sleeve and shall be mounted on high strength DMC material, inter connection of incoming and outging cable etc and Bottom base channel of MS section not less then 50 mm x 50 mm x 5 mm thick grouted in PCC block of size 30 cm x30 x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate and connection of cables with suitable size of thimble, nuts, bolts & washers including cable glands at entry and outlet points including execavation and earth work, returing filling and removal of surplus soil, double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers as per site requirement with the following :-
(a) CT's of suitable ratio (Set of three) (b) Digital Voltmeter & Ammeter - 02 Nos (b) Phase indicator lamp RYB LED type - 1 Set (Set of three) Incoming: (a) MCCB 125 Amp 415V, 50 Hz, FP, 36 ka, Ics= 100% Icu, fixed type complete all as specified and directed by Engr-in-Charge. Note :- Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE.
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick MS sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 400 Amp Cap of length not less than 60 cm and suitable size of strip for 3 phase and neutral with colour code heat shrinkable sleeve and shall be mounted on high strength DMC material, inter connection of incoming and outging cable etc and Bottom base channel of MS section not less then 50 mm x 50 mm x 5 mm thick grouted in PCC block of size 30 cm x30 x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate and connection of cables with suitable size of thimble, nuts, bolts & washers including cable glands at entry and outlet points including execavation and earth work, returing filling and removal of surplus soil, double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers as per site requirement with the following :- (a) CT's ration 400/05, CL 1.0 Tape wound - 01 set (Set of three) (b) Digital Voltmeter & Ammeter - 02 Nos (b) Phase indicator lamp RYB LED type - 1 Set (Set of three) Incoming: (a) MCCB 250 Amp 415V, 50 Hz, FP, 36 ka, Ics= 100% Icu, fixed type complete all as specified and directed by Engr-in-Charge. Note :- Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE.
Supply, installing, testing and commissioning of LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 600 Amp insulated copper strip of length not less than 60 cm and suitable size of strip for 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-300A, with Amp meter push button type- 01 Set. (iii) C.T's of suitable ratio (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).
Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider or equivalent as approved. INCOMING SUPPLY :- (i) MCCB 400 Amps 36 KA , ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No OUTGOING SUPPLY :- (i) MCCB 250 Amps 25 KA , 4 Pole fied type, 415 volts , 50Hz,=02 No., (ii) MCCB 160 Amps 25 KA , 4 pole, fixed type, 415 volts , 50Hz,=02No. (iii)MCCB 100 Amps 16 KA , 4 pole, fixed type, 415 volts , 50Hz,=02No. Make of MCCB:-L&T/ Siemens / Legrand or equivalent as approved. Note :- 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE. 4. All MCCB's shall be employ Ics= 100% of Icu
Material and labour for MCCB 4 Pole, 415 V, fixed type,thermal magnatic load ICS100% of ICU, 63 Amps with breaking capacity 16 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, fixed type,thermal magnatic load ICS100% of ICU, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 160 Amps with breaking capacity 25 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 400 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Outdoor/indoor 70 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 185 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
Straight through joint kit indoor/outdoor al conductor cable of size 70 to 150 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 185 Sqmm and 3.5/4 core
Supply and fix Powder coated Pin Type Panel lock in round shape (Male & Female socket) diameter of suitable size fixed properly in existing LT panel including necessary welding work as directed by Engr-in-charge.
S&F in repair non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
S&F in repair non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
Trimming of tree in vicinity of electric supply pole/street light pole/ two pole/four pole structure, transformer, LT panels, bus bar, feeder pillar etc in a radius of 3 mtr approx all as specified and directed.
Supply and fixing and passing through pipes/poles cable 1.5 Sqmm 2 core cable, PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, confirming to IS :694 including replacement of old unsv cable.
Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -03 Phase,50 Hz, 415 Volts of capacity 200 amps automatic /manual with inbuilt time delay alongwith suitable contactor, support terminates should be enclosed in wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound confirming to IP-54 all as specified and directed by Engr-in-Charge.
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3180114)
ANIKET TRADERS (BID ID -3181394)
RANBIR ENTERPRISES (BID ID -3179614)
MOHAN LAL AND SONS (BID ID -3185472)
MAHAJAN TRADING CO (BID ID -3179949)
DAVINDER SINGH (BID ID -3179601)
slathia construction works (BID ID -3180069)
ASIA BUILDER (BID ID -3178057)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .