Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹13.4 L+₹2.3 L (21.2%)Rejected-Finance M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹14.4 L+₹3.4 L (30.3%)Rejected-Finance JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹17.3 L+₹6.2 L (56.3%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR/ REPLACEMENT / IMPROVEMENT OF LT OH/UG SYSTEM,GOD SWITCHES,CIRCUIT BREAKERS OF 11 KV/66 KVA POWER HOUSE AND CONNECTED ALLIED WORKS UNDER GE(WEST) PATHANKOT
2021_MES_475365_1
GE/PKT-47/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹40,000
Yes
30 Nov 2021
15 Sept 2021
15 Oct 2021
15 Sept 2021
13 Oct 2021
30 Sept 2021
16 Sept 2021 - 25 Sept 2021
60 days
Amount
M&L for Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
All as per ser item No. 1 here-in-before but depth exceeding 1.5 mtr bur n. exceeding 3 mtr.
M&L for Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable and punned down to 18 cm complete all as specified and directed. Note :- Punned thickness 18 cm will be measured for payment.
M&L for Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid complete all as specified and directed.
M&L for Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 ( Using 40mm graded stone aggregate ) as in foundation of poles filling and mass concrete complete all as specified and directed
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate) as in foundation of poles/coping,stay etc complete all as specified and directed
M&L for Prestressed concrete pole, 9.0 metres long 102mm x 152mm at top and 102 mm x 289 mm at bottom, class 10 in replacement including dismantling of old UNSV pole , numbering new pole and applying two coats of synethic enamel paint upto 1.5 mtr height from top of coping in black and white strip alternately each 30 cm wide complete all as specified and directed. (Note: Earth work including excavation ,Returning filing,PCC work,removing excated material will be measured and paid separetly under respective items of schedule)
M&L for ACSR conductor for over head lines on pole stretching without kinks and bends including binding wire and dismantling old UNSV ACSR conductor complete all as specified & directed.
Dismantlimg old unsv earth wire from pole and S & F Galvanized steel continuous earth wire 4mm dia including stringing for earth conductor on poles including binding etc & fabrication of cradle guards hexagonal/rectangular complete all as specified and directed.
Dismantling old UNSV cross arms , clamps ,nuts,bolts washers etc from poles and S&F in replacement cross arm bracing supports clamps and back plate fabricated from structural steel section including nuts, bolts,washers,welding,bending hot or cold drilling holes for bolts in any shape or size including of two coats of aluminium paint over and including a coat of red oxide primer complete all as specified and directed.
M&L for stay assembly complete using stay rod of 20 mm dia 180 cm long, stay bow, stay clamp complete with accessories as shown in electrical plate No 01 of MES SSR Part-I including dismentling of old UNSV stay from ground and pole (loop type insulator,stay clamps ,excavation and PCC shall be measured & Paid for separately) complete all as specified and directed.
M&L for galvanized stay strand of size 7/3.15 mm complete all as specified and directed.
M&L for Loop type insulator (for stay assembly vitreous porcelain white, brown or green large size with over all dimentions 140mm clearance of hole 25.5 mm complete all as specified and directed.
M&L for Shackle type porcelain vitreous white, brown or green insulator in replacement having working pressure 1100 Volts of 90mm dia 115mm height including galvanized mild steel strip of size 31x3mm, 12mm dia insulator nuts, bolt and washers including dismantling Old UNSV insulator complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and earth lead protected by provision of GI medium grade pipe 40mm bore including provision of PCC (1:2:4) type B-1 as in pit and 40mm thick pit cover of RCC (1;2:4) reinfored with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, 15 cm thick layer of common salt and charcoal filling arround the earth plate with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceeding 50 mtr complete all as per plate No 3 of SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate eletrode of size 60xm x 60cm x6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete for pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick pit cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, 15 cm thick layer of charcoal and common salt filling alround the earth plate, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meterrs, complete all as per plate No-3, SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion complete all as specified and directed.
M&L for 10 sq mm 2core XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 2 core including taking down of old UNSV cable complete all as specified and directed. (NOTE : Earth work including excavation ,returning Filling,removing,sand coushioning,brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule)
All as per ser Item No 19 here-in-before but 16 sq mm 2 core
M&L for 25 sq mm 4 core, XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, including taking down of old UNSV cable complete all as specified and directed. NOTE : Earth work including excavation ,returning Filling,removing,sand coushioning,brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule
All as per ser Item No 21 here-in-before but 35 Sqmm 3.5 core
All as per ser Item No 21 here-in-before but 50 sq mm 3.5 Core
All as per ser Item No 21 here-in-before but 70 sq mm 3.5 Core
All as per ser Item No 21 here-in-before but 95 sq mm 3.5 Core
All as per ser Item No 21 here-in-before but 120 sq mm 3.5 Core
M&L for 50 mm bore GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of sizes complete all as specified and directed.
All as per ser Item No 27 here-in-before but 80 mm bore
M&L for Pruning of tree branches and making clear LT/HT OH line to the minimum distance of 30 mtrs span for 2/3/4/5/6 conductors complete all as specified and directed.
Supply & fixing of ACB 630 amp ,4 pole 415 volts ,3 phase ,50 Hz AC fixed type manual operated with microprocessor release IPR E+ (4Pole) & 50 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The ACB shall have spreader links and barriers as standard feature of manufacturer with MS enclosure grouted in PCC (1:2:4) type B-1 with PCC complete all as specified and directed. Make: Havells cat part no IHAFE1E060883 or equivalent in any of the make mentioned in approved list of product.
M&L for PVC over head line spacer suitable for 5 wires to fix on LT over head line complete all as specified and directed.
All as per ser item No 31 here-in-before but 4 wires
All as per ser item No 31 here-in-before but 3 wires
All as per ser item No 31 here-in-before but 2 wires
M&L for earth continuity conductor of size 32X6 mm copper strip,fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
M&L for earth continuity conductor of size 25X3 mm aluminium strip,fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed
M&L for GI strip 24x4 mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
M&L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and painting with two coats of aluminium paint over and including a coat of red oxide primer complete all as specified and directed.
M&L for coarse stone aggregates, grading 63 to 40mm size Kankar without any vegitation including levelling /sprending in surrounding of HT/LT 2/3/4 pole structure/Installations/LT/HT panel/around transformer plateforms complete all as specified and directed. Note :-( Rates are deemed to be included for setting the existing bricks reqd for retaing the aggregare if any)
M&L for stretching existing loose ACSR conductors of OH lines run of 2/3/4/5 span minimum 30 mtrs including GI wire along the spans on LT poles for sagging within the permissible limit including removing existing winding & rewinding with AI winding wire for condouctor and GI widing wire for GI wire with existing iron components fixed on pole .Size of winding wire shall not be less than two Sqmm complete all as specified and directed .
M&L for painting iron bracing fixed on pole i.e brackets ,clamps ,street light clamps and anti climbing devices, cross arms etc complete with two coats of aluminium paints after preparing the surface dirt/grease complete all as specified and directed.
M&L for preparing the surfaces of PCC Poles(HT/LT) upto 150 cm height from coping and painting with synthetic enameled paint in alternate strips with black & yellow color 30 cm high strip (total 05 Nos) and writing pole numbers size of letters 50mm high with white enamel paint on black paint base after pole painting, complete all as specified and directed.
M&L for Cleaning of unwanted vegitation/grass around the panel/RMUs/Two pole /transformer plateform including earth work upto 10 cm depth and upto 2 mtr wide all around from the panels/transformers plateforms and surface dressing including spreading and ramming complete all as specified and directed.
Supply and fixing in repair aluminium lugs of size 50 Sqmm to be crimped properly to LT cable with crimping tool complete all as spd and directed.
Supply and fixing in repair aluminium lugs of size 70 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Supply and fixing in repair aluminium lugs of size 95 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
M&L for Danger notice plate 20cmx15cm size made out of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, complete all as specified and directed.
Supply and fixing in repair/replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular of cross sectional area 10 sq mm stranded conductor complete all as specified and directed.
Supply and fixing in replacement 11 KV Air break switch gang operated (GOD) triple pole mechanically operated,mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (86,915.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
KEWAL SONS
JAI DURGA CONSTRUCTION CO
M/S Raghuvanshi Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .