Garrison Engineer (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2026_MES_785172_1
GE(S)/PAT/T-55/2026-27
Open Tender
Civil Works
Item Rate
240 days
Sangrur
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹80,000
Yes
19 Aug 2026
19 Aug 2026
11 Sept 2026
19 Aug 2026
9 Sept 2026
2 Sept 2026
19 Aug 2026 - 26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1'Notes: (i) Please refer Schedule 'A' Notes of tender documents. | |||||
| 2 | Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged etc by the user in any time (day and Night) in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT line etc complete repairs to the extent by removing connections from the system removing faults in wires, bAttens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to the entire satisfaction of Engr-in-Charge/users.
Note :- Complaints relating to repair of switches, fans, regulators, burnt/damaged wiring, burnt MCBs, main switches, voltage fluctuations, current leakage, street light faults, tube lights not working, "no light" complaints and similar urgent nature complaints shall be considered urgent and Attended within 8 hours of receipt of complaint.
Cost of taking out U/s Accessories is deemed to be included but S/F of new accessories will be measured and paid saperatly.
(b) Petty item such as insulation tap, small wire pieces, screw etc is deemed to be included with unit rate of this item.
(c) The complaints will be Attended by electricians & respective helpers during day and night hours without delay.
'(d) The complaint will be taken from complaint cell. All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost.
(e) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor.
'(f) One mobile phone should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff. | 3,000 | Each Complaint | - | - |
| 2.1 | (g) Complaint register and complaint slip shall be providing by the contractor duly printed with CA No and firm and the cost is deemed to be included in unit rate.
(h) Item No. 2 is a labour-only item covering complaints such as no light, loose connections, repair of burnt wires, shifting of fittings/fixtures, temporary arrangements for light/fan, phase balancing by load sharing and similar maintenance activities.
(j) Complaints involving supply and fixing of switches, sockets, regulators, ceiling roses, bell pushes, lamp holders, sunken boxes, PVC plates, wiring, LED battens, LED fittings, LED surface-mounted lights, fan blades, exhaust fan louvers, PVC exhaust fans, PVC conduits and similar items shall be carried out as day-to-day maintenance works. The cost of new materials shall be measured and paid separately under the relevant BOQ items. The contractor shall also provide tradesmen on a daily basis as specified and directed.
(k) If the complaint is not attend within the prescribed time frame, a penalty of Rs. 250/- per complaint per day till completion of complaint shall be recovered from the contractor's dues.
(l) Contractor/ bidder shall provide proper 02 set of uniform (winter & summer) to his employees/ workers as approved by the GE.
(m) Safety equipment shall be provided by the bidder/ contarctor to his employees/ workers and the cost of the same included in the unit quoted rate & nothing extra shall be paid by the Govt.
(n) The bidder/ contractor's rep shall be deposit the complaint slip duly signed by the user in token of satisfied completion of complaint to the concrened JE.
(o) Payment shall be processed with mentioned complaint slip No. in the MB and same be uploaded in eMB portal please
(p) Successful bidder shall calculate the quantities of various materials to be incorporated against each item of BOQ. 50% quantities of approved make from the GE shall be procured and handed over to Engr-in-Charge within 15 days from the stipulated date of commencement. Contractor shall submit the original purchase voucher along with so procured material to the Engr-in-Charge for his verification and entry in the MB accordingly. After consumption of first lot of material, same process shall be repeated by the contractor and the Engr-in-Charge for balance quantity of material.
(q) Bidders attention is drawn to the fact that claim of running payment shall only be entertained after compliance of condition stipulated vide note no (p) herein above. | - | - | - | - |
| 3 | Supply and fixing piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed. | 50 | Each | - | - |
| 4 | Supply and fixing piano switch Swich piano, bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz supply. | 50 | Each | - | - |
| 5 | Supply and fixing piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed. | 50 | Each | - | - |
| 6 | Supply and fixing socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed. | 50 | Each | - | - |
| 7 | Supply and fixing Modular switch socket combination with gang box 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed. | 25 | Each | - | - |
| 8 | Supply and fixing Modular switch socket combination with gang box 2 in 1, 3 pin 15 Amps flush type, 230 volts Ac circuit complete all as specified and directed. | 50 | Each | - | - |
| 9 | Supply and fixing ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed. | 50 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
T-55.pdf
Tender Documents • 0.74 MB
BOQ_879807.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].