Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC 184 NEAR GOODWAY TAILORS PRITHVIPURA RASAL ROAD BRIDGE JODHPUR RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | ₹7.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹7.6 Cr+₹48.6 L (6.86%)Rejected-AOC | ₹7.6 Cr+₹48.6 L (6.86%) | L2 | Rejected-AOC L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Non Responsive |
Tender Value
Refer Docs
EMD Value
₹13 L
Closing Date
28 Oct 2024, 12:00 pmClosed
CGM PPND,AEGCL
CGM PPND,AEGCL
Supply, dismantling, construction, erection and commissioning of 2 Nos 220 kV Bays at 400/220 kV Misa S/s (POWERGRID) and associated works etc
2024_AEGEF_38744_1
. AEGCL/MD/AIIB/PKG-E/Part 2/BID
Open Tender
Power/Energy Projects/Products
Turn-key
270 days
MISA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
₹13 L
Yes
23 Apr 2025
2 Sept 2024
29 Oct 2024
2 Sept 2024
28 Oct 2024
18 Sept 2024
2 Sept 2024 - 9 Sept 2024
Amount
Circuit Breakers with with terminal connector, operating mechanism & support structure as per technical specifications
245 kV , 3 phase , single pole, 2500A , 50 kA auto-reclosing SF6 Breaker
Control & Relay Panel with auto re-closer as per technical specifications
For 220 kV Feeder Control and protection Panel with standalone LBB and bus bar protection scheme to be connected to existing centralised bus bar scheme: control panel (1no) + relay panel (1 no) = 1 set (for each bay)
Samast compliant ABT meter as per philisophy of CTUIL/Grid India
Current Transformers including all accessories and terminal connector as per technical specification
245 kV, 1600-1200-800/1-1-1-1-1 Line CT
Marshalling box for CT (shall be supplied by CT manufacturer)
PLCC Equipment
245 kV 220/√3/0.110/√3 CVT with 3 core along with terminal connector
Marshalling box for CVT (shall be supplied by CVT manufacturer)
245 kV, 1250A Wave Trap (pedastal mounted) along with terminal connector
Digital protection coupler with PLC terminal
LMU/LMDU
HF Co axial cable 75 ohm
OFC 24 pair for interconnection of line OPGW junction box to CRP and from CRP to SAS panel including conduit pipe
1600A, 50kA for 1 sec Horizontal Double Break Isolators with mounting structure and post insulators, terminal connector as per technical specification
220 kV horizontal double break Isolator Without Earth Switch
220 kV horizontal double break Isolator With single Earth Switch
220 kV horizontal double break Isolator With double Earth Switch
1600A, 50kA for 1 sec Horizontal Double Break Beam mounted Isolators and post insulators, terminal connector as per technical specification
220 kV Isolator Without Earth Switch (Beam mounted arrangement)
Lightning Arrester including all accessories and terminal connector as per technical specification
216 kV Lightning Arrester with surge counter and accessories
Post Insulator including terminal connector as per technical specification
245 kV Bus Post Insulator for 8 no bus post for each bay and 2 no insulator for each post
245 kV Post Insulator for Wave trap (8 no insulator for each wave trap)
Supply of Lattice type Mounting structures of all equipment including nuts , bolts, washers and foundation bolts
216 kV Lightning Arrester
Support structure for HDB 220 kV isolator
Supply of Armoured Power and Control Cables
i)19Cx1.5 sq mm Control Cable (copper)
ii) 12Cx1.5 sq mm Control Cable (copper)
iii) 7Cx1.5 sq mm Control Cable (copper)
iv) 4Cx2.5 sq mm Control Cable (copper)
v) 4Cx 16 sq mm Power Cable (Aluminium)
vi) 3.5Cx 70 sq mm Power Cable (Aluminium)
Cable glands, lugs & straight through joints for Power & control cable for the two numbers of 220kV line bays
Bay Marshalling Kiosk
Clamps, connectors and other acessories for 4 inch Aluminium tube as per site requirement
Clamps, spacers, connectors for connecting the buses to the equipments
(a) 220kV T-Connector suitable for AAAC Zebra conductor to ACSR Moose conductor.
(b) 220kV Clamp Connector suitable for AAAC Zebra to Wave Trap.
(c) 220kV UPG Clamp Connector suitable for ASCR Single Moose conductor.
(d) 220kV T-Connector suitable for single ASCR Moose conductor to Single ACSR Moose conductor
Illumination
Indoor Lighting
Lighting System including MCB DB, Cabling, Conduiting, wiring, Switches, Socket, Junction boxes, auxiliary receptacle etc for Kiosk room
Outdoor lighting Lighting
Supply of Outdoor LED lighting for switchyard including lighting distribution board, cables, switches, socket, auxilary receptacle, MCBs whever necessary
2 TON capacity industrial type split air conditioning units for KIOSK with automatic controller ( one main and one standby)
Earthing
Earthing Conductor: 75X12mm GI Flat main earth mat extension and 75x10 mm For Equipment and Structure Earthing,
Earthing Conductor: 50X6 mm GI Flat For Riser For Marshalling Boxes, Cable Trenches Etc.,
Earthing Device & Associated Accessories (50 mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit as per drawing provided
40 mm dia 3 meter long MS rod electrode for Kiosk earthing provision
GI conduit, Patch cords, cable LIU (multimode, 24 port) required for SAS integration
ACSR "MOOSE" Conductor
Mandatory spares
120 KN double suspension hardware fitting with 120 KN porcellain insulator
120 KN double tension hardware fitting with 120 KN porcellain insulator
Spacers for twin moose jumpers
Description of Work / Item(s)
Amount
Circuit Breakers with with terminal connector, operating mechanism & support structure as per technical specifications
245 kV , 3 phase , single pole, 2500A , 50 kA auto-reclosing SF6 Breaker
Control & Relay Panel with auto re-closer as per technical specifications
For 220 kV Feeder Control and protection Panel with standalone LBB and bus bar protection scheme to be connected to existing centralised bus bar scheme: control panel (1no) + relay panel (1 no) = 1 set (for each bay)
Samast compliant ABT meter as per philisophy of CTUIL/Grid India
Current Transformers including all accessories and terminal connector as per technical specification
245 kV, 1600-1200-800/1-1-1-1-1 Line CT
Marshalling box for CT (shall be supplied by CT manufacturer)
PLCC Equipment
245 kV 220/√3/0.110/√3 CVT with 3 core along with terminal connector
Marshalling box for CVT (shall be supplied by CVT manufacturer)
245 kV, 1250A Wave Trap (pedastal mounted) along with terminal connector
Digital protection coupler with PLC terminal
LMU/LMDU
HF Co axial cable 75 ohm
OFC 24 pair for interconnection of line OPGW junction box to CRP and from CRP to SAS panel including conduit pipe
1600A, 50kA for 1 sec Horizontal Double Break Isolators with mounting structure and post insulators, terminal connector as per technical specification
220 kV horizontal double break Isolator Without Earth Switch
220 kV horizontal double break Isolator With single Earth Switch
220 kV horizontal double break Isolator With double Earth Switch
1600A, 50kA for 1 sec Horizontal Double Break Beam mounted Isolators and post insulators, terminal connector as per technical specification
220 kV Isolator Without Earth Switch (Beam mounted arrangement)
Lightning Arrester including all accessories and terminal connector as per technical specification
216 kV Lightning Arrester with surge counter and accessories
Post Insulator including terminal connector as per technical specification
245 kV Bus Post Insulator for 8 no bus post for each bay and 2 no insulator for each post
245 kV Post Insulator for Wave trap (8 no insulator for each wave trap)
Supply of Lattice type Mounting structures of all equipment including nuts , bolts, washers and foundation bolts
216 kV Lightning Arrester
Support structure for HDB 220 kV isolator
Supply of Armoured Power and Control Cables
i)19Cx1.5 sq mm Control Cable (copper)
ii) 12Cx1.5 sq mm Control Cable (copper)
iii) 7Cx1.5 sq mm Control Cable (copper)
iv) 4Cx2.5 sq mm Control Cable (copper)
v) 4Cx 16 sq mm Power Cable (Aluminium)
vi) 3.5Cx 70 sq mm Power Cable (Aluminium)
Cable glands, lugs & straight through joints for Power & control cable for the two numbers of 220kV line bays
Bay Marshalling Kiosk
Clamps, connectors and other acessories for 4 inch Aluminium tube as per site requirement
Clamps, spacers, connectors for connecting the buses to the equipments
(a) 220kV T-Connector suitable for AAAC Zebra conductor to ACSR Moose conductor.
(b) 220kV Clamp Connector suitable for AAAC Zebra to Wave Trap.
(c) 220kV UPG Clamp Connector suitable for ASCR Single Moose conductor.
(d) 220kV T-Connector suitable for single ASCR Moose conductor to Single ACSR Moose conductor
Illumination
Indoor Lighting
Lighting System including MCB DB, Cabling, Conduiting, wiring, Switches, Socket, Junction boxes, auxiliary receptacle etc for Kiosk room
Outdoor lighting Lighting
Supply of Outdoor LED lighting for switchyard including lighting distribution board, cables, switches, socket, auxilary receptacle, MCBs whever necessary
2 TON capacity industrial type split air conditioning units for KIOSK with automatic controller ( one main and one standby)
Earthing
Earthing Conductor: 75X12mm GI Flat main earth mat extension and 75x10 mm For Equipment and Structure Earthing,
Earthing Conductor: 50X6 mm GI Flat For Riser For Marshalling Boxes, Cable Trenches Etc.,
Earthing Device & Associated Accessories (50 mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit as per drawing provided
40 mm dia 3 meter long MS rod electrode for Kiosk earthing provision
GI conduit, Patch cords, cable LIU (multimode, 24 port) required for SAS integration
ACSR "MOOSE" Conductor
Mandatory spares
120 KN double suspension hardware fitting with 120 KN porcellain insulator
120 KN double tension hardware fitting with 120 KN porcellain insulator
Spacers for twin moose jumpers
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of local LT power and control cables as required
245 kV 3 phase suitable for single-cum-three phase auto-reclosing operation SF6 circuit Breaker
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables, ABT meter as required
For 220 kV Feeder Control and protection Panel with standalone LBB and bus bar protection scheme to be connected to centralised bus bar scheme
Erection, testing & commissioning of Current transformers on the existing support structure including retrofitting of structure as necessary, laying & terminating of local control and power cables, outdoor marshalling box etc
245 kV, CT of current ratio 1600-1200-800/1-1-1-1-1
Erection, testing & commissioning of capacitive Voltage Transformers on existing support structures including laying of local control and power cables, outdoor marshalling box etc.
245 kV, CVT of ratio 220/√3/0.110/√3 CVT
Erection, testing & commissioning of Wave trap
220 kV, Wave trap
Erection, testing & commissioning of HDB Isolators including laying & terminating of local LT power and control cables as required
220 kV Horizontal double break Isolator Without Earth Switch
220 kV Horizontal double break Isolator With Single Earth Switch
220 kV Horizontal double break Isolator With Double Earth Switch
Erection, testing & commissioning of Beam mounted Isolators including laying & terminating of LT power and control cables as required
220 kV Horizontal double break isolator Without Earth Switch (Beam mounted arrangement)
Erection, Testing & Commissioning of Lightning Arrester
216 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator on existing tubular support structures including retrofitting of structure as necessary
220 kV Bus Post Insulator
220 kV Post Insulator for Wave trap on existing lattice structures
Erection, testing and commissioning of outdoor BMKs, Indoor and outdoor illumination system, ACs for kiosk room
Construction of new foundation with erection of mounting structure (modification and retrofiiting may be done if feasible) for Circuit Breakers.
(i) 245 kV single-cum-three phase auto-reclosing SF6 circuit Breaker
Construction of new foundation with erection of mounting structure (modification and retrofiiting may be done if feasible) for Isolator
220 kV Without Earth Switch
220 kV With single Earth Switch
220 kV With double Earth Switch
Construction of new foundation with erection of mounting structure (modification and retrofiiting may be done if feasible) for Lightning Arrester.
216 kV Lightning Arrester
Construction of new foundation with erection of mounting structure (modification and retrofiiting may be done if feasible) for Wave trap
220 kV Wave Trap
Integration of 2 nos. new 220kV line bays Substation Automation System with the existing SAS along with addition of extra signals in SAS
Construction of PCC base of 100mm thick along with 100 mm thick gravelling (crushed stone layer of 100 mm thick with size 20mm crushed stone over a 100 mm thick PCC layer of 1:3:6 nominal ratio) including levelling, compaction of the site.
Installation of earthing system with earthpit, GI flats, electrodes connecting with existing earthing mat, earthing of equipment and structures (as required) etc
Laying of control cables in trenches including dressing ,termination, glanding in terminal equipment with all material as per technical specification
i)19Cx1.5 sq mm Control Cable (copper)
ii) 12Cx1.5 sq mm Control Cable (copper)
iii) 7Cx1.5 sq mm Control Cable (copper)
iv) 4Cx2.5 sq mm Control Cable (copper)
Laying power cable and termination including dressing, binding in Cable Trench, glanding in Terminal equipment with all materials as per Technical specification
i) 4Cx 16 sq mm Power Cable (Aluminium)
ii) 3.5Cx 70 sq mm Power Cable (Aluminium)
Laying of Optical Fiber and High Frequency Co-Axial Cable including dressing and Termination as per Technical specification
i) High frequency Co-Axial cable
ii) Optical Fibre Cable for inter connection of OPG to C&R Panel and SAS equipment
Dismantling of existing 220kV bay equipments and structures (as per requirement) and shifting of the equipments to location as specified by POWERGRID for 2 Nos Bays
Construction of Switchyard Kiosk Room building (9 meter x 5.5 meter x 4.5 meter)as per architectural drawing provided
Design and Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
Type A
Type C
Type D
Hoisting of ACSR Moose Conductor
HI-TECH CORPORATION (BID ID -241110)
Telmos Electronics (BID ID -243615)
Telmos Electronics (BID ID -243615)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .