Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹33.2 L+₹1.1 L (3.29%)Admitted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Admitted-Finance | |
| 3 | L3₹34.5 L+₹2.4 L (7.38%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹35.6 L+₹3.5 L (10.9%)Admitted-Finance 73 5 NANAK NAGAR JAMMU 180004 J K | JAMMU | JAMMU | J K | 180004 | L4 | Admitted-Finance | |
| 5 | L5₹36.4 L+₹4.3 L (13.4%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L2 | Allied Technologies L4 | Nitika electricals and engineers works L5 | M/S KALSI ENGINEERS AND CONTRACTORS L1 | M/S J S ENGINEERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Identifying and rectifying the defects pertaining to internal electrification & summer appliances of any type and nature such as taking down and replacement of defective switch/socket/ceiling rose/holders/fittings /fixtures/ MCBs/MCB DBs and items such as desert coolers/fridges/deep freezers/ACs/Geysers/fans etc as the items of any type/model, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc. complete all as specified and directed.
NOTE:- (a) All T & P/Stationeries and labour team required comprising of minimum 02 Nos of trained electricians daily and 01 Refrigeration mechanic as per requirement will be provided by the contractor as directed by Engineer in charge.
(b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 16.30 Hrs daily the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor.
(c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, gutties, rawal plugs as required at site etc shall be deemed included in the above quoted item. However, major items such as switches, sockets, bell push, fan regulator, MCBs, holders, light fittings, DBs, wiring and parts of ACs/deep freezers/desert coolers/fans etc shall be measured and paid separately as supply only under relevant item of Schedule 'A'. and labour item shall be deemed to be included in the item rate. | 2,400 | Each Job | 70 ₹1,68,000 | 20 ₹48,000 Lowest | 40 ₹96,000 | 40 ₹96,000 | 50 ₹1,20,000 |
| 1.01(d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after reciving complaint, Rs 1000/- per complaint per day will be recovered from the contractor. (f) Contractor will provide complete tool kits/safety equipments for electricians and Refrigerator mechanic including dress to working staff in the contract. Also safety of electricians/refg mech is completely responsible by the contractor is deemed to be included in the item rate. (g) If case of any urgent nature of complaint contractor has to provide the electricians for to attend the complaints after 1630 hrs also including sundays/holidays as per direction of Engr-in-Charge.If any complaint of urgent nature is not attended within 02 hrs, then a penalty of Rs.200 per hour of delay shall be levied upon the contractor. Any disputes regarding this matter, the decision of GE shall be final and binding. (h) A complaint register will be maintained by the contractor bearing details of every coomplaint attended shall be entered by the contractor daily including details like building No, Location etc, and the register shall be signed by contrcator, JE and Engineer in Charge. The register will be submitted alongwith RAR/ Final bill for technical check. (j) All the items under Supply only items of BoQ shall be obtained from contractor under proper receipt voucher. | ||||||||
| 2.00 | Supply only Switch piano flush type 5 Amps single pole one way complete all as specified and directed. | 400 | Each | 15 ₹6,000 Lowest | 30 ₹12,000 | 20 ₹8,000 | 21 ₹8,400 | 22 ₹8,800 |
| 3.00 | Supply only switch piano flush type 15 Amps single pole one way complete all as specified and directed. | 50 | Each | 59 ₹2,950 | 50 ₹2,500 Lowest | 80 ₹4,000 | 80 ₹4,000 | 55 ₹2,750 |
| 4.00 | Supply only Socket out let multipurpose suitable for 2/3 pin 5 Amp flush type complete all as specified and directed. | 50 | Each | 26 ₹1,300 Lowest | 60 ₹3,000 | 80 ₹4,000 | 70 ₹3,500 | 30 ₹1,500 |
| 5.00 | Supply only Socket out let multipurpose suitable for 3/5 pin 15 Amp flush type complete all as specified and directed. | 50 | Each | 61 ₹3,050 | 70 ₹3,500 | 110 ₹5,500 | 100 ₹5,000 | 50 ₹2,500 Lowest |
| 6.00 | Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. | 700 | Each | 60 ₹42,000 Lowest | 90 ₹63,000 | 80 ₹56,000 | 120 ₹84,000 | 70 ₹49,000 |
| 7.00 | Supply only Switch socket combination 2 in 1 5 pin 15 Amps flush type complete all as specified and directed. | 700 | Each | 105 ₹73,500 | 125 ₹87,500 | 120 ₹84,000 | 150 ₹1,05,000 | 100 ₹70,000 Lowest |
| 8.00 | Supply only Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body surface type 65mm x 50mm 2 to 3 terminal complete all as specified and directed. | 100 | Each | 30 ₹3,000 | 30 ₹3,000 | 25 ₹2,500 Lowest | 25 ₹2,500 Lowest | 30 ₹3,000 |
| 9.00 | Supply only Electronic modular 5 step fan regulator 1/2 module 100 watt as per site requirement electronic,step type and connection complete all as specified and directed. | 25 | Each | 190 ₹4,750 | 350 ₹8,750 | 180 ₹4,500 Lowest | 250 ₹6,250 | 200 ₹5,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
18 Jul 2026, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIRS/MAINT OF INTERNAL WIRING, CEILING FAN, AC, DESERT COOLER AND DAY TO DAY COMPLAINTS OF INTERNAL ELECTRIFICATION AND REP/REPLACEMENT OF PERIMETER SECURITY LIGHTS, FLOOD LIGHTS WITH OTHER CONNECTED ITEMS AT 213 TRANSIT CAMP UNDER GE NAGROTA
2026_MES_771402_1
CANO GEN/TOKEN-26/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NAGROTA
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹90,000
Yes
24 Jul 2026
20 Jun 2026
23 Jul 2026
20 Jun 2026
18 Jul 2026
4 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Identifying and rectifying the defects pertaining to internal electrification & summer appliances of any type and nature such as taking down and replacement of defective switch/socket/ceiling rose/holders/fittings /fixtures/ MCBs/MCB DBs and items such as desert coolers/fridges/deep freezers/ACs/Geysers/fans etc as the items of any type/model, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc. complete all as specified and directed.
NOTE:- (a) All T & P/Stationeries and labour team required comprising of minimum 02 Nos of trained electricians daily and 01 Refrigeration mechanic as per requirement will be provided by the contractor as directed by Engineer in charge.
(b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 16.30 Hrs daily the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor.
(c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, gutties, rawal plugs as required at site etc shall be deemed included in the above quoted item. However, major items such as switches, sockets, bell push, fan regulator, MCBs, holders, light fittings, DBs, wiring and parts of ACs/deep freezers/desert coolers/fans etc shall be measured and paid separately as supply only under relevant item of Schedule 'A'. and labour item shall be deemed to be included in the item rate. | 2,400 | Each Job | - | - |
| 1.01 | (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item.
(e) If contractor fails to rectify the complaint with in 24 hours after reciving complaint, Rs 1000/- per complaint per day will be recovered from the contractor.
(f) Contractor will provide complete tool kits/safety equipments for electricians and Refrigerator mechanic including dress to working staff in the contract. Also safety of electricians/refg mech is completely responsible by the contractor is deemed to be included in the item rate.
(g) If case of any urgent nature of complaint contractor has to provide the electricians for to attend the complaints after 1630 hrs also including sundays/holidays as per direction of Engr-in-Charge.If any complaint of urgent nature is not attended within 02 hrs, then a penalty of Rs.200 per hour of delay shall be levied upon the contractor. Any disputes regarding this matter, the decision of GE shall be final and binding.
(h) A complaint register will be maintained by the contractor bearing details of every coomplaint attended shall be entered by the contractor daily including details like building No, Location etc, and the register shall be signed by contrcator, JE and Engineer in Charge. The register will be submitted alongwith RAR/ Final bill for technical check.
(j) All the items under Supply only items of BoQ shall be obtained from contractor under proper receipt voucher. | - | - | - | - |
| 2 | Supply only Switch piano flush type 5 Amps single pole one way complete all as specified and directed. | 400 | Each | - | - |
| 3 | Supply only switch piano flush type 15 Amps single pole one way complete all as specified and directed. | 50 | Each | - | - |
| 4 | Supply only Socket out let multipurpose suitable for 2/3 pin 5 Amp flush type complete all as specified and directed. | 50 | Each | - | - |
| 5 | Supply only Socket out let multipurpose suitable for 3/5 pin 15 Amp flush type complete all as specified and directed. | 50 | Each | - | - |
| 6 | Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. | 700 | Each | - | - |
| 7 | Supply only Switch socket combination 2 in 1 5 pin 15 Amps flush type complete all as specified and directed. | 700 | Each | - | - |
| 8 | Supply only Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body surface type 65mm x 50mm 2 to 3 terminal complete all as specified and directed. | 100 | Each | - | - |
| 9 | Supply only Electronic modular step fan regulator 1/2 module as per site requirement electronic,step type and connection complete all as specified and directed. | 25 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender26.pdf
Tender Documents • 1.07 MB
BOQ_866323.xls
BOQ • 1.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .