Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L1 | Accepted-AOC Performance security Rs. 79,500.00 shall be submitted before 28 days from the acceptance of the contract as per Condition 19 of IAFW2249 otherwise necessary action will be taken against your firm | |
| 2 | L2₹18.1 L+₹1.2 L (6.94%)Rejected-Finance 0 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹18.7 L+₹1.8 L (10.7%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹21.7 L+₹4.8 L (28.2%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹30.7 L+₹13.8 L (81.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | A S ENTERPRISES L2 | M/S vibhuti enterprises L3 | bharat construction L4 | Krishna Enterprises L1 | OASIS CONTRACTORS BUILDERS & SUPPLIERS L5 | Pradeep traders L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for opening up the winding of ceiling fan 1200 mm any make and type and rewinding with super enamelled copper winding wire with suitable gauge winding ,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. | 280 | Each | 350 ₹98,000 | 320 ₹89,600 | 380 ₹1,06,400 | 200 ₹56,000 Lowest | 800 ₹2,24,000 | 500 ₹1,40,000 |
| 2.00 | M&L for opening up the winding of ceiling fan any 1400 mm any make and type and rewinding with super enamelled copper winding wire with suitable gauge winding ,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. | 250 | Each | 380 ₹95,000 | 320 ₹80,000 | 425 ₹1,06,250 | 200 ₹50,000 Lowest | 900 ₹2,25,000 | 500 ₹1,25,000 |
| 3.00 | S&F ball bearing No. 6201, | 650 | Each | 45 ₹29,250 | 30 ₹19,500 Lowest | 48 ₹31,200 | 30 ₹19,500 Lowest | 60 ₹39,000 | 60 ₹39,000 |
| 4.00 | S&F ball bearing No. 6202, | 720 | Each | 45 ₹32,400 | 30 ₹21,600 Lowest | 49 ₹35,280 | 30 ₹21,600 Lowest | 65 ₹46,800 | 60 ₹43,200 |
| 5.00 | S&F in replacement capacitor of 2.5 MFD, | 750 | Each | 25 ₹18,750 Lowest | 28 ₹21,000 | 36 ₹27,000 | 30 ₹22,500 | 40 ₹30,000 | 40 ₹30,000 |
| 6.00 | S&F in replacement capacitor 3.15 MFD | 550 | Each | 25 ₹13,750 | 30 ₹16,500 | 5 ₹2,750 Lowest | 35 ₹19,250 | 50 ₹27,500 | 55 ₹30,250 |
| 7.00 | S&F rubber reel suitable for ceiling fan of any capacity complete all as specified and directed. | 320 | Each | 30 ₹9,600 | 2 ₹640 Lowest | 60 ₹19,200 | 5 ₹1,600 | 25 ₹8,000 | 38 ₹12,160 |
| 8.00 | S&F worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed. | 240 | Each | 45 ₹10,800 | 20 ₹4,800 Lowest | 48 ₹11,520 | 20 ₹4,800 Lowest | 100 ₹24,000 | 45 ₹10,800 |
| 9.00 | M&L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed. | 530 | Each | 60 ₹31,800 | 40 ₹21,200 Lowest | 40 ₹21,200 Lowest | 40 ₹21,200 Lowest | 100 ₹53,000 | 200 ₹1,06,000 |
| 10.00 | S&F in replacement PVC cable copper conductor multi strandrad flexible 23/76 twin core and making connections from ceiling rose to fan complete all as specified and directed. | 520 | RM | 8 ₹4,160 Lowest | 50 ₹26,000 | 40 ₹20,800 | 23 ₹11,960 | 30 ₹15,600 | 40 ₹20,800 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Jun 2025, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
REPAIR/MAINT TO STORAGE TYPE WATER HEATER, SOLAR WATER HEATER, CEILING FAN, EXHAUST FAN, WATER COOLR, DESERT COOLER, REFRIGERATOR, DEEP FREEZER, OTHER COOLING APPLIANCES INSTALLED AT AF STN BAMRAULI
2025_MES_707537_1
8957/E8
Open Tender
Civil Works - Others
Works
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹70,000
Yes
23 Sept 2025
9 May 2025
6 Jun 2025
9 May 2025
4 Jun 2025
23 May 2025
Amount
M&L for opening up the winding of ceiling fan 1200 mm any make and type and rewinding with super enamelled copper winding wire with suitable gauge winding ,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of ceiling fan any 1400 mm any make and type and rewinding with super enamelled copper winding wire with suitable gauge winding ,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F ball bearing No. 6201,
S&F ball bearing No. 6202,
S&F in replacement capacitor of 2.5 MFD,
S&F in replacement capacitor 3.15 MFD
S&F rubber reel suitable for ceiling fan of any capacity complete all as specified and directed.
S&F worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed.
M&L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/76 twin core and making connections from ceiling rose to fan complete all as specified and directed.
S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample).
S&F ceiling fan down rod 0.3 mtr long duly made out off mild steel including rubber bush/ reel nut, bolt, washer and split pin complete all as specified and directed.
S&F down rod for ceiling fan made out of galvanized iron pipe of size 15mm dia medium grade (ISI marked) of length 1mtr/1.20/1.5 metre (As per site reqd) including threading, cutting, slotting, drilling including nut, bolt, clip, washer and rubber real complete all as specified and directed.
M&L for collection of unserviceable pedestal fan/Wall fan / cabin fan (any make any size) form AGE E/M stores or taking down from users residence for carrying out the repair, reassembling the same including replacement of wornout nuts, bolts and washers, MS clip screw split pin, ball bearing, bush rubber reel including derusting, servicing, oiling greasing, rewinding of fan motor reinstalling, testing and making electric connection to ensure and making electric connection to ensure proper functioning and commissioning complete all as specified and directed. Note : The unit rate includes the cost of all spares material as mentioned above except rewinding of fan motor, bush and ball bearing. The rewinding of fan, moter, bush & bell bearing shall be measured paid separately.
Rewinding to fan motor of any capacity of any make with supper enameled copper winding wire of existing size and quantity including insulating materials i.e varnish, sleeves etc with full satisfaction of Engr-in-Charge for following :-
(a) Wall fan / Cabin fan 350/400 mm sweep any make
(b) Pedestal fan 400/450 mm sweep any make
S&F bush for the pedestal fan/Wall fan / cabin fan of any make and any sweep complete all as specified and directed.
S&F ball bearing for pedestal fan/Wall fan / cabin fan fan/exhaust fan & cabin fan complete all as specified and directed.
S&F worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed.
S&F in replacement capacitor of 1/1.50 MFD,
S&F gear box for pedestal fan/Wall fan / cabin fan fan/exhaust fan & cabin fan complete all as specified and directed.
M&L for collection of unserviceable Exhaust fan (any make any size) form AGE E/M stores or taking down from users residence for carrying out the repair, reassembling the same including replacement of wornout nuts, bolts and washers, MS clip screw split pin, ball bearing, bush rubber reel including derusting, servicing, oiling greasing, rewinding of fan motor reinstalling, testing and making electric connection to ensure and making electric connection to ensure proper functioning and commissioning complete all as specified and directed. Note : The unit rate includes the cost of all spares material as mentioned above except rewinding of fan motor, bush and ball bearing. The rewinding of fan, moter, bush & bell bearing shall be measured paid separately.
Rewinding to fan motor of capacity of any make with supper enameled copper winding wire of existing size and quantity including insulating materials ie varnish, sleeves etc with full satisfaction of Engr-in-Charge for following :-
(a) Exhaust fan 220 mm to 300 mm sweep any make
(b) Exhaust fan 375mm sweep any make
(c) Exhaust fan 450mm sweep/Air circulator 600mm sweep of any make
(d) Air Circulator Industrial type 750 mm sweep
S&F bush for the exhaust fan of any make and any sweep complete all as specified and directed.
S&F ball bearing for exhaust fan complete all as specified and directed. Make : NBC/SKF or equivalent as approved
S&F Condenser but 4 MFD complete all as specified and directed.
S&F in repair Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250 mm size Fresh air fan as per sample complete all as specified and directed.
S&F in repair Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 200 mm size Fresh air fan as per sample complete all as specified and directed.
S&F exhaust fan motor capacity 1/4 HP 230 volts suitable for 300 mm size exhaust fan complete all as specified and directed.
M&L for painting of Exhaust fan including fan blade of any make or any sweep at site with one coat of synthetic enamel paint on old painted surface by brush including cleaning all dust/oil/greasing etc by soft soap solution and rewriting existing MES number with black paint complete to the entire satisfaction and as directed by Engr-in-Charge.
S&F in repair A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired of Make : North West / Havells / Legrand complete as specified after taking out old unserviceable starter unit all as specified and directed.
S&F in repair C curve series MCB SP 6 to 32 Amp, 240 volts, 10 KA complete all as specified and directed.
S&F in repair C cuurve MCB SP 40 Amp rating 240 volt 10 KA complete all as specified and directed.
S&F C curve series MCB SPN 32 Amp, 240 volts, 10 KA complete all as specified and directed.
S&F C curve series MCB SPN 40 to 63 amp, 240 volts, 10 KA complete all as specified and directed.
M&L for (in replacement) only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor all as specified and directed by Engr-in-Charge.
S&F in replacement PVC box comprising of switch socket combination multi - purpose 5 pin, 6/16 Amp box type complete all as specified and as directed.
S&F in replacement PVC box comprising of switch socket combination multi - purpose 3 pin, 6 Amp box type complete all as specified and as directed.
M&L for tape roll big size complete all as specified and directed.
S&F in replacement of fusible plug type air release valve complete all as specified and directed by Engr-in-Charge.
S&F in replacement of gasket of thickness 5mm for geyser assembly of 06/08/09 holes complete all as specified and directed.
S&F in replacement apparatus plate assembly of 06/08/09 holes suitable for 25/35/50 Ltrs geysers with suitable size of nut bolts/stud/washer complete all as specified and directed.
S&F in replacement of indicating lamp for geyser rectangular /round type red/ green suitable for any type of geyser complete all as specified and directed.
S&F in replacement of inner tank vertical type suitable for 25 Ltr geyser duly enamel coated steel tank of Geyser of gauge 18 SWG of capacity complete all as specified and directed.
S&F in replacement of inner tank vertical type suitable for 35/50 Ltr geyser duly enamel coated steel tank of Geyser of gauge 18 SWG of capacity complete all as specified and directed.
S&F in replacement rubber ring of existing size with mild steel ring clamp to lower and upper housing of geyser 25/35/50 Ltr complete all as specified and directed.
S&F in repair angle valve chromium plated cast copper alloy screwed down high pressure concealed type screwed both ends of size 15 mm bore complete all as specified and directed
S&F in repair gate valves (Gun metal globe valve) with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm dia, complete all as specified and directed. Note: The quoted rate is deemed to be inclusive of cutting, threading, insertion of union joint, nipple etc for the required size of pipe.
S&F in repair bib tap chromium plated of size 15 mm bore complete all as specified and directed
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete all as specified and directed Note : Taking down and fixing shall be paid separately
S&F in replacement of PVC insulated flexible copper wire 3 core of size 40/.0076 complete all as specified and directed.
S&F SS braided pipe of 12 mm (Internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F SS braided pipe of 12 mm (Internal) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F in repair thermostat switch suitable for geysers of capacity 25 ltrs of any make including star rated geysers complete all as specified and directed.
S&F in replacement thermostat any type of geyser complete all as specified and directed.
S&F in replacement heating element 2 KW, triangle type with rubber gasket suitable for geysers of 25/50 ltrs any make complete all as specified and directed.
S&F in replacement heating element modular type of capacity 2 KW, Modular type suitable for star rated modular type geysers of make Bajaj/ Racold/Jaquar with rubber gasket complete all as specified and directed.
S&F in repair plug top 15 Amp 3 pin complete all as specified and directed.
S&F in repair plug top 5 Amp 3 pin complete all as specified and directed.
M&L for (in replacement) plug top, 3 pin, 10/20 amp earth metal clad (ISI marked) complete all as specified and directed.
S&F in replacement socket 3 pin 10/20 amp earth metal clad (ISI marked) all as specified and directed.
M&L for (in replacement) fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser /Exhaust Fan all as specified and directed.
DESERT COOLER. Taking down/out desert cooler of any make and capacity from various locations and M & L for complete cleaning washing and descaling scraping down and removing existing paint, preparation of surface and painting the entire/complete body of desert cooler, inside and outside, by sprayer with two coats of approved synthetic enamel paint and writing SM/ MES no. with black synthetic enamel paint by complete all as specified and directed by Engr-in-Charge.
M&L for desert cooler’s cabinet, locally fabricated with three side panels (front, top and tank) and vertical members made out plain galvanised iron sheet with double diversion grills and grill box suitable for 18” sweep fan and making holes for connections with and including fixing arrangements such as 4 way PVC distributor, PVC pipe 3 to 4 Mtrs for spraying water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 Amps piano type switch etc complete all as specified and directed.
S&F water lifting pump submersible type upto 1.5 Meter head,40 Watt Suitable for 220-240V, AC 50 Hz 1 Phase and including taking out existing defective pump from Desert Coolers, complete all as specified and directed.Make : Khaitan or equivalant
S&F in replacement of ready made wood wool pad with Meshes of size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed.
S&F in replacment of Desert cooler fan motor operating on SP 230 Volts, 50 HZ AC, 150 W,1400 rpm,copper winding with fan blade and mounting Kit complete after and including taking out existing fan motor all as specified and directed. Make : Khaitan or crompton or Equivalent as approved by Eng-in-Charge
S&F of PVC sheathed and PVC insulated 3 core cable, 1.5 Sqmm copper conductor of Make: Plaza/ Gloster / Havells / Kalinga complete all as specified and directed.
M&L for replacement of PVC pipe 10 mm bore standard quality of desert cooler complete with fixing arrangement, all as specified and directed.
S&F condenser 4 Mfd for kit/exhaust fan motor of Make: Epcos / Asian / Keltron complete all as specified and directed.
S&F Clamp for kit fan motor as per site requirement with nut, bolt & washers complete all as specified and directed.
S&F Piano type switch 5 Amps of Make: Anchor / Cona / Kay.
S&F PVC water distributor, (Set of four way and two way).
S&F plug top 5amp 3 pin type Make:- Anchor/Standerd/Kay
S&F in replacement MS duly spray painted exhaust fan blade 300mm/380mm sweep complete all as specified and directed.
S&F Polycarbonate duly spray painted kit fan blade 300mm/380mm sweep complete all as specified and directed.
M&L for repair or rewinding with super enameled copper winding wire of exhaust fan motor of desert cooler any type any make including all minor parts like bush,bearing etc all as specified and directed by Engr-in-Charge.
S&F GI Tubing 'Medium grade' of 15 mm size as per existing with screwed socket joints, togather with all tube fitting to connect desert coolar with water pipe line complete all as specified and directed by Eng-in-Charge. Note : Cost of bands, Tees, reducing tees ,ends ,elbow, connectors,caps etc and other minor parts not specifically mentioned shall also be replaced where required for proper functioning shall be demanded to be included in the quoted rate. No extra payment shall be made to the contractor on this account.
S&F angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed as specified and directed by Engr-in-Charge.
S&F ball valves (Float Valve) high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe as specified and directed by Engr-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 300 mm ( PTMT fitting shall be of approved makes)
S&F in repair plywood grade BWR type BB of thickness 4.0 mm fixed with screws to timber frame work all as specified and directed.
WATER COOLER. Dismantling of electric connection and water connection of water cooler opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of U/S parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified and directed. Note : New spares replaced against Worn out or unserviceable spare parts shall be measured and paid separately as supply only under respective item of this sch.
Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and dischrage line with gas welding work including supply and filling of refrigerent gas R-22 or as per existing at site in suitable quantity as per manufacturers instruction complete all as specified and directed.
All as per item No 84 above but water cooler of capacity 60 Ltrs/hr
All as per item No 84 above but water cooler of capacity 150 Ltrs/hr Note (For item No 84 to 86) :- (i) Cost of transportation from store to factory and back shall be deemed to be included in the quoted rates. (ii) GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (iii) All new compressor shall be purchased from authorised dealer only. (iv) Capillary, drier, filter strainer are inclusive in unit rate.
M&L for replacement of Rubber hose pipe of 20 mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long complete all as specified and directed
M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified and directed
M&L for making the system leak proof and charging of gas R-22 / R-134a or existing at site as required in water cooler of any capacity including replacement of drier and capillary tube and testing on load complete all as specified and directed
M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed.
M&L for replacement of condenser fan motor of SP, 230V, cap 1/35 HP with fan blade all as specified and directed
M&L for replacement of condenser fan motor of SP, 230V, cap 1/8 HP with fan blade all as specified and directed
Supply and replacement of 15mm bore Push cock/lift cock brass chromium plated.
Supply and replacement of flexible PVC pipe 40mm/50mm/60mm as per requirement for the drainage of waste water of water coolers all as specified and directed by Engnr-in charge.
Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or at work shop testing for leak proof complete all as specified and directed. Note : (a) Nipple adaptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate.
Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as specified and directed.
Dismantling of electric connection and water connection of water purifier (RO) , electrical accessories and spare parts of system carefully servicing of serviceable parts and replacement of U/S parts reassembling all spare parts incl rewiring of internal connection, testing and commissioning complete all as specified and directed. Note :Minor parts like conection pvc pipe,overflow ,waterflow switch etc are included in quoted rate
Supply only the following items for water cooler :-
(a) Starting capacitor 60/80 mfd
(b) Running capacitor 10 mfd
(c) Thermostat
(d) Relay
(e) Over load protector
(f) Wiring kit
(g) Strainer/filter drum type/pen type
(h) Door gasket
REFRIGERATORS. Repair maint of refrigerator of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator all as specified and directed. Note : Replaced worn out part shall be measured and paid separately as supply only.
M&L for detection of leakage in refregeration of capacity 260L/310L and repairing thoroughly to ensure the complete system leak proof and charging of refrigerant gas as per existing on site with appropriate quality incl necessary brazing, welding, testing and commissioning complete all as specified and directed by Engr-in-Charge. Note : Replacement of Capillary, drier and copper tubing/filter strainer are inclusive in unit rate.
Dismantling of unserviceable sealed compressor unit from refrigerator and replacing with new compressor as existing capacity and charging of refrigerant gas of appropriate qty and testing for smooth functioning complete all as specified and directed. Note : (a) New compressor will be purchased from authorised dealer only. (b) Capillary, drier and additional copper tubing are included in unit rate. (c) Old compressor either cut open or sealed to be replaced with new one.
Supply only the following item for refrigerators as per sample :-
(a) Thermostat switch as per sample
(b) Relay box type as per sample
(c) Door gasket as per sample
(d) Cooling coil as per sample
(e) Condensing coil as per sample
(f) Freezer door any make
(g) door switch
(h) Bulb Holder
(j) Door Handle
(k) Lamp
(l) Door Lock
(m) bottle holder shelves any size
(n) Vegetable tray with cover
(o) Main shelves
(p) water filter for samsung Refrigertor
(q) Printed circuit board for invertor type Refrigertor of capacity upto 320 Ltrs for existing model
DEEP FREEZER. M&L for Repair maint of deep freezer of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of deep freezer all as specified and directed. Note : Replaced worn out part shall be measured and paid separately as supply only.
M&L for making the system leak proof and charging of gas as required in Deep Freezer of any make of capacity up to 400Ltr including replacement of drier and capillary tubing and testing on load complete all as specified and directed.
Supply and replacing Cable 3 core flexible heavy duty copper cable of size 2.5 sqmm for AC , Water Cooler ,Stabilizer etc. complete all as specified and directed.
Removing burnt/defective sealed compressor unit of any make from DEEP FREEZER of any capacity by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and dischrage line with gas welding work including supply and filling of refrigerent gas R-22 in suitable quantity as per manufacturers instruction complete all as specified and directed.
M&L for replacement of PVC sheet rubber bedding and lock of top cover of deep freezer of any type and by screwing/welding MS Sheet of top cover complete all as specified and directed.
M&L for replacement of condenser fan motor of SP, 230V, cap 1/50 HP with fan blade for refrigerator or deep freezer all as specified and directed.
Supply only the following item for Deep Freezer as per sample :-
(a) Thermostatic switch for any capacity
(b) Relay /capictor any type for any capacity as per sample
(c) Door gasket as per sample
(d) Cooling coil as per sample
(e) Condensing coil as per sample
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material
A S ENTERPRISES (BID ID -3305452)
M/S vibhuti enterprises (BID ID -3305775)
bharat construction (BID ID -3306977)
OASIS CONTRACTORS BUILDERS & SUPPLIERS (BID ID -3306787)
Pradeep traders (BID ID -3312822)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .