Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹33.8 L+₹3.9 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹41.8 L+₹11.9 L (39.9%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹42.9 L+₹13.0 L (43.3%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹43.9 L+₹14.0 L (47.0%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Nov 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPECIAL REPAIR TO BLDG NO. T-13, T-14 AT DIBRUGARH AND CERTAIN REVENUE AND MINOR WORKS UNDER GE DINJAN
2022_MES_551061_2
C/8484/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹80,000
Yes
23 Nov 2022
7 Nov 2022
21 Nov 2022
7 Nov 2022
19 Nov 2022
14 Nov 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, or laying of cables, poles, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Dismantling asbestos cement (corrugated semi corrugated etc) sheet in roof covering complete all as specified and as directed.
Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed.
Dismantling of timber fillets, rails, posts, rafters, purlins etc under 40 sqcm in section complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
M&L for hardcore of brocken bricks or boulder, of gauge not exc. 63 mm, deposited, spread, and leveled in layers not exc 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
M&L for PCC , type D2 (1:4:8), (using 40mm graded broken stone aggregate) as in foundations, filling and mass concrete, pole etc complete all as specified and as directed.
M&L for PCC, type B2 (1:2:4), (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC, type B2 (1:2:4), (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 75mm thick PCC, type D2, (1:4:8), (using 40mm graded broken stone aggregate) as in sub base of floor etc complete all as specified and as directed.
M&L for RCC (1:2:4), type B1, (20 mm graded agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping), rough finished flat surface of concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
M&L for GI Wire netting 0.90 mm dia, size of mesh 12 mm, lathing to wood or metal studding, joists, etc in walls, etc including all laps, cutting and waste complete all as specified and as directed.
M&L 12 mm thick rendering on one side of lathing in cement mortar (1:6) and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 18 mm thick on other side of lathing surfaces in two layers (12 mm and 6 mm thick) in cement mortar (1:4) using water proofing compound in top layer and finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound measured and paid separately.
Supply only liquid water proofing compound complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for rendering 10 mm thick of internal wall on fair faces of brick work or concrete surfaces in cement mortar in (1:6) and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) including finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed.
S&F for hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for 4 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws including three coats of white wash on surface of ceiling/boards etc complete all as specified and as directed.
M&L for second class hardwood, timber scantlings, clean swan as in framed and fixed, with nails complete all as specified and as directed.
S&F for pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for granite (of any type) tiles 18- 20mm thick machine cut, bedded and jointed with grey cement slurry including 15mm thick screed bed or bedding in cement mortar (1:6) and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F for rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 290 (Gde E-165) complete all as specified and as directed.
S&F for mild steel screw bolts (machine made) 11 to 15 mm with hexagonal head at one end and screwed the other end, or screwed both ends, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolt not exceeding 5cm long complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/ hard standing, etc finishing surface even and fair without using extra cement making joints with bitumastic filling in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 300X 200X 7 mm thick over 10 mm thick backing coat in cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 450X 350X 7 mm thick over 10 mm thick backing coat in cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed.
M&L for granite (of any type) tiles 18 to 20mm thick machine cut in skirting /dado / vertical surface laid over 10mm thick backing coat in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed bed or bedding layer of cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Taking down chowkhats or frames not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) complete all as specified and as directed.
M&L for second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
M&L for 35 mm thick second Class Hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F for 30mm thick, glazed/skelton shutters with second class hard wood,open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of members of shutter as specified in SSR Part I Section 8, clause 8.24 (b) complete all as specified and as directed.
S&F for 35mm thick, glazed/skelton shutters with second class hard wood, open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of members of shutter as specified in SSR Part I Section 8, clause 8.24 (a) complete all as specified and as directed.
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F for 75 mm long, butt hinges, medium weight, cold rolled mild steel fixed to chowkats complete all as specified and as directed.
S&F for 100mm long butt hinges, medium weight, cold rolled mild steel fixed to chowkats complete all as specified and as directed.
S&F for aluminium anodised barrel tower bolts of extruded section 100 mm long complete all as specified and as directed.
S&F for aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and as directed.
S&F for aluminium handle 100 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F for aluminium handle 150 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F for 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails, cross sectional area exceeding 3 Sqcm and not exceeding 6 Sqcm complete all as specified and as directed.
S&F for second class hard wood plain fillets, bull nosed, splayed, chamfered or rounded on one edge wrought, fixed with screws, cross sectional area exceeding 3 Sqcm and not exceeding 6 Sqcm complete all as specified and as directed.
M&L for preparation of new untreated wood and wood based surfaces of any description, but not exeeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new surfaces of wood and wood based surface, of any description and girth, not otherwise described and treated creosote oil complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of distempering interior walls with distemper oil emulsion white or tinted over chalk whiting complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over alkali resistant priming paint complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls by washing, rubbing down and scraping of existing distempering/painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and greases spots and applying two coats of cement base paint (white or tinted) complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin white flat back size 630x450mm excluding taps, waste, coupling, chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
S&F for vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste., chain and plug and porcelain stopper with bracket including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
S&F in repairs sink with drainage board, made out of stainless steel 1.00mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm and bowl size 410X330X160mm complete all as specified and as directed. Make : Prayag/Anjali/Blue Star.
S&F in repair 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 15 mm bore dia pillar taps, chromium plated, cast copper alloy, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F for 15 mm bore dia pillar taps, chromium plated, cast copper alloy, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F in repairs 15 mm bore dia cast copper alloy fancy type, chromium plated stop valves, crewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for 15mm stop valves (concealed type), cast copper alloy fancy type chromium plated, long sunk and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for brass chromium plated shower rose, 125 mm size fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs for PVC connections 15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed.
S&F in repair towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
S&F for tubular towel rail, 20mm dia, D type, 60cm long brass chromium plated between flanges complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F for 15 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
S&F for 20 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
S&F for 25mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to laid in trenches etc complete all as specified and as directed.
S&F for 40mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to laid in trenches etc complete all as specified and as directed.
Cutting into existing 15/20 mm GI pipe line making necessary arrangement gor taping of new pipe line of 25 mm dia including threading, welding complete all as specified and as directed.
Cutting the existing 50/40 mm bore GI pipe line and making necessary arrangement for taping of new pipe line of 25mm dia including threading, welding and all required accessories complete all as specified and as directed.
Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 litres but not exceeding 1000 Ltrs complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position complete all as specified and as directed.
S&F for 20 mm bore dia of pipe, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20 mm - 210 gms) complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4) including finished the surface even and smooth without using extra cement complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F in repairs 20mm bore, gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions complete all as specified and as directed.
S&F for 25 mm bore, gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
S&F for 40 mm bore, gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
M&L for valve pit and construction of brick masonry valve pit of internal dimension 40 x 40 x 40 cm depth with sub class 'B' bricks in CM (1:6) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:2:4) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 5 mm angle iron and 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down unserviceable sub-main wiring with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof and including provision of PVC insulated FRLSH 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion for one light/ fan point/ bell buzzer point controlled by one way 6 Amp modular switch complete all as specified and as directed. Note : Cost of PVC conduit, cover plate and box of suitable module, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per item No 106 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.
All as per item No 106 above but for one 3 pin switch socket combination, 5 Amps on Independent board complete all as specified and as directed.
All as per item No. 106 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 3 pin switch socket combination, 5/15 Amps on Independent board complete all as specified and as directed..
S&F for switch piano, 5 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED bulb of 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj.
S&F in repair stepped type (five steps) electronic fan regulator flush type complete all as specified and as directed. Make : Model No. 14502 of Anchor or equivalent.
S&F for 18/20 Watt, surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F 45 watt Cub LED building security light fitting including with GI bracket of 25 mm bore not less than 1 mtr comes with pressure die cast housing, prismatic polycarbonate diffuser, LEDs with secondary optic and IP65 protection complete all as specified and as directed.
S&F for 10 Watt, LED, energy saving new generation bulk head luminaire with opal diffuser including lamp incl connecting with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Havells/Philips/Bajaj//Crompton/Century.
Taking down main switch /MCB/ MCCB/ Cut out etc. any type, any size complete all as specified and as directed.
S&F for regal batten holder for LED tube (Single side connection) fitting with ultra bright LED tube light (Single side connection) with very high efficiency to give glare free light with necessary connection complete all as specified and directed. Make : Cat No. REGALBATTEN8UPTO2X22WDSBSWH (Batten), PHOTON ULTRA+1213T8SSTL20W LED865SPC (LED tube G13) of Havells or equivalent.
S&F for factory made board distribution (DB), double door in steel sheet enclosure with 200 amps rated common bus bar at incoming end, SPN, 4 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed. Make : Cat No : DHDPSHODRW04 of Havells or equivalent.
S&F for factory made board distribution (DB), double door in steel sheet enclosure with 200 amps rated common bus bar at incoming end, SPN, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed. Make : Cat No : DHDPSHODRW08 of Havells or equivalent.
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. TSPC6-32 of HPL or equivalent.
S&F MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No TSPNC6-32 of HPL or equivalent.
M&L for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep including taking down old unserviceable complete all as specified and as directed.
M&L for sub main wiring with two run of 10 Sqmm (nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, fixed to wall/ceiling etc including one run of 10 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets)
Taking down carefully serviceable ceiling fan/ exhaust fan / wall mounted fan deposited in safe custody, after repair work fix in original position after minor repair complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4mm GI wire by means of bolts and nuts checknuts and washers protected by 20mm bore galvanised iron light grade pipe, funnel with 40mm bore GI medium grade pipe for watering, wire mesh including concrete pit PCC 1:3:6 type C1, precast RCC 1:2:4 type B1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 150 mm center to center in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, including necessary excavation and earth work in any type of soil, all as specified and shown in electrical plate no 3 of SSR part-1 complete all as specified and directed and tested on completion.
S&F in repairs recess mounted deep drawn size (2 ft x 2 ft) CRCA housing with higher power 34 Watt LED Seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed. Make : Cat. No. PLUTONEO 2x2 PLR 34 W LED 840S of Havells/Philips/Bajaj.
Refixing of LED tubelight as obtained by taking down complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw including removing the existing old unserviceable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including taking out old unserviceable cable complete all as specified and as directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 23cm spread thick ness and consolidated (punned) upto 18cm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid for.
M&L for sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed.
Labour only for horizontal boring road/ foot path, not exceeding 15 mtr in length by any method for 40 mm dia GI pipe complete all as specified and as directed.
S&F for 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors using suitable clamp / holder complete all as specified and as directed.
M/S N K SAI TRADING
FREEZCON
M/S CHANDAN ENTERPRISE
M/S HAZARIKA CONSTRUCTION
M/s. R. K. Trading Company
M/S AUTOMOTIVE WORLD
M/s GANDHESWAR PHUKAN
R.D.CONSTRUCTION
STANDARD ELECTRIC WINDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .