Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.1 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹63.6 L+₹4.5 L (7.56%)Rejected-Finance 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹74.8 L+₹15.7 L (26.5%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹75.1 L+₹16.0 L (27.1%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹75.2 L+₹16.1 L (27.2%)Rejected-Finance | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹76.2 L
EMD Value
₹1.4 L
Closing Date
19 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col V S Sengar
HQ 138 Works Engineers PIN-914138 C/O 56 APO
PROVN OF ALTERNATE CIRUCUITS AND ASSOCIATES INFRA IN CERTAIN CRITICAL AREA IN CORPS HQ BLDGS SERVO STABILIZERS AT NEW CORPS POWER HOUSE AND POWER FACTOR SYSTEM AT OLD CORPS POWER HOUSE UNDER GE 865 EWS AT LEH
2022_MES_562676_1
138WE/L-59/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.4 L
Yes
6 Jan 2023
11 Nov 2022
26 Dec 2022
11 Nov 2022
19 Dec 2022
2 Dec 2022
Amount
Supply, Install testing and commissioning of Servo Stabilizer Digital Microprocessor based , Fully Automatic 3 Phase, 50 Hz 400 KVA for automatic operation, three phase suitable for unbalanced input naturally oil cooled, indoor type, Copper EC grade (99.9% Pure) copper wound metallic body duly powder coated with lifting hooks 04 Nos, digital display type, relay free smooth and silent operation with filling of Transformer Oil ISI 335 marked upto level having following specfications:- (a) Input voltage 330V - 470Volt phase to phase. (b) Output voltage stabilized at any design/ desired voltage 415 volt+_ 1% (c) rated frequency 50 Hz. (d) No destoration in wave form. (e) Response time not to exceed 20 milli seconds (f) Efficiency more than 95 % (g) Type of load: 3 Phase, Unbalanced type. (h) Digital display voltmeter/ Ammeter (i) 3 Nos. Copper Variable Auto transformers one for each phase. (j) 3 Nos. Heavy duty AC synchronous motor for individual phase correction. (k) 3 Nos. buck/boost Transformer. (l) 3 Nos. Control circuits for individual phase control. (m) Control Panel Display ; I/P Metering , O/P Metering , Indication, Alarm (n) Speed of Correction : >than 35 V / Sec., Response less than 10MS (o) Regulation : 1.0% from No Load to full load (p) Insulation : class A (q) Accuracy ; + 10% from no load to full load. Protections:- (i) Overload/ short circuit protections (ii)) High/ low voltage cut off (iii) Bi-pass arrangement in case of emergency. (iv) Single phase sequence change protection. (v) Overload capacity ; should withstand 20% overload for 60 sec and 10% overload for 30 sec.
All as per item No 1 above but of capacity 500 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 1 above but of capacity 250 KVA, complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade 400 Sqmm 3 1/2 core with stranded aluminius conductor, complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and including GI Strip 32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs, complete all as specified and directed by Engr-in-Charge.
M&L for Point wiring for one light point or fan point controlled by one switch with PVC insulated copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in sunk CI/ pressed steel terminal boxes for fixing and 1.5 sqmm PVC FRLS insulated copper wire as earth wire connected to earth dolly and 3.00 mm thick plastic lamiated sheet cover, complete all as specified and directed by Engr-in-Charge.
All as per item No. 6 here -in-before but 1.5 sqmm for one 3 pin 5 Amps socket outlet on same board including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on same board, complete all as specified and directed by Engr-in-Charge..
All as per item No. 6 here -in-before but 1.5 sqmm for one 3 pin 5 Amps socket outlet independent including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly, complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for 3pin 15 Amps socket outlet independent with copper conductor cable PVC insulated multistrand 2.5 Sqmm with 1 .5 sqmm PVC copper conductor as earth wire connected to earth dolly and including PVC casing/caping with sunk cast iron, complete all as specified and directed by Engr-in-Charge.
S&F switch socket outlet , 3pin 5 Amps piano flush type single pole ISI marked complete, complete all as specified and directed by Engr-in-Charge.
S&F switch socket outlet 2in 1, 3 pin 5 and 15 Amps piano flush type single pole ISI marked, complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type single pole one way 5 Amps ISI marked, complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 3 pin 5Amps flush type, complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface bakelite two or three terminal all as specified and directed by Engr-in-Charge.
M&L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engr-in-Charge.
S&F LED lamp 07 Watt 230V, complete all as specified and as directed by Engr-in-Charge.
Supply and Fix Surface/wall mounted LED fittings with LED tube 18 watts capacity (Warm White) decorative ultra slim elegance LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient type, 4 feet long channel type bracket including neccessary connection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose/PVC connector to light fittings, complete all as specified and directed by Engr-in-Charge.
S & F for Surface / ceiling mounting 2x2 LED 36 Watts Luminaire fitting including neccessary connection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose/PVC connector to light fittings, complete all as specified and directed by Engr-in-Charge.
Supply & fix for wiring for PVC Capping Casing circuit/submain wiring alongwith earth wire with the sizes 4x16Sqmm + 2x10 Sqmm of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required, complete all as specified and directed by Engr-in-Charge.
All as per item No 19 but 4x10Sqmm + 2x6 Sqmm of FRLS PVC insulated copper conductor, complete all as specified and directed by Engr-in-Charge.
All as per item No 19 but 2x16Sqmm +1x10 Sqmm of FRLS PVC Insulated copper conductor, complete all as specified and directed by Engr-in-Charge.
All as per item No 19 but 2x10Sqmm +1x6 Sqmm of FRLS PVC Insulated copper conductor, complete all as specified and directed by Engr-in-Charge.
All as per item No 19 but 2x6Sqmm +1x4 Sqmm of FRLS PVC Insulated copper conductor, complete all as specified and directed by Engr-in-Charge.
All as per item No 19 but 2x4Sqmm +1x2.5 Sqmm of FRLS PVC Insulated copper conductor.
S&F for sheet metal enclosure TPN DBs with 200 Amps rated bus bar of 4 way 415 volts with blank plate, complete with double door, complete all as specified and directed by Engr-in-Charge.
S&F for sheet metal enclosure SPN DBs with 200 Amps rated bus bar of 12 way 240 volts with blank plate complete with double door, complete all as specified and directed by Engr-in-Charge.
S&F in sheet metal enclosure SPN DBs with 200 Amps rated bus bar of 8 way 240 volts with blank plate complete with double door, complete all as specified and directed by Engr-in-Charge.
S&F for MCB TPN 125Amps 'C' series complete all specified and directed by Engr-In-Charge.
S&F for MCB TPN 100Amps 'C' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB TPN 63Amps 'B' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB SPN 63Amps 'B' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB SPN 40Amps 'C' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB SP 6 to 32 Amps 'B' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB SP 40 Amps 'B' series, complete all specified and directed by Engr-In-Charge.
S&F for MCB SP 63Amps 'B' series, complete all specified and directed by Engr-In-Charge.
S&F for Busbar Chamber 200 Amps Capacity 8Way, complete all as specified and directed by Engr-in-Charge.
S&F for Busbar Chamber 100 Amps Capacity 4Way, complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore light grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order.(ii) Item includes the cost of 7.5 m GI earth lead, complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning outdoor type 200 KVAR with 6 steps (2x12.5 + 1x25 + 3x50) APFC panel with MD-XL capacitor with HRC protection including 400 Amps, 35 KA, 3P MCCBas incomer with 11 tank process for corrosion proof powder coating on panel, Ergonomic, compact and robust design with Fully copper conductors. Advance C-MOS technology based micro processor relay for intelligent power factor control. Air core reactor for extra safety from inrush current (High currents). Provision of top and bottom cable entry, Automatic temp. control through fans and louvers in panel. Double side earthing connection. Ref. standard: IEC 61921/ IS 8623 / IS 16636 /IEC 61439. To continuously sense and monitor the load conditions by the use of the external CT (whose output is fed to the control relay). To automatically switch ON and switch OFF relevant capacitor steps to ensure consistent power factor. To ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out etc. To protect against any electrical faults in a manner that will ensure safe isolation of the power factor correction equipment, complete all as specified and as directed by Engineer-In-Charge.
All as per item No 39 above but 125 KVAR with 5 steps (2x12.5 + 2x25 + 50) APFC panel with MD-XL capacitor with HRC protection including 250 Amps, 35 KA 3P MCCB as incomer complete all as specified and as directed by Engineer-In-Charge.
All as per item No 39 above but 150 KVAR with 6 steps s (2x12.5 + 3x25 + 50) APFC panel with MD-XL capacitor with HRC protection including 315 Amps, 35 KA 3P MCCB as incomer complete all as specified and as directed by Engineer-In-Charge.
All as per item No 39 above but 300 KVAR with 6 steps (1x100 + 3x50 + 2x25) APFC panel with MD-XL capacitor with HRC protection including 630 Amps, 35 KA, 3P MCCB as incomer complete all as specified and as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and as directed by Engineer-In-Charge.
All as per item No: 43 bove but 185 Sqmm 3 1/2 core, complete all as specified and as directed by Engineer-In-Charge.
All as per item No: 43 bove but 630 Sqmm 3 1/2 core, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in Hard/Dence soil & getting out for laying of cable, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in including spreading leveling watering & well ramming in layers n exc. 25 Cm thick, complete all as specified and as directed by Engineer-In-Charge.
Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point complete all as specified, complete all as specified and as directed by Engineer-In-Charge.
Material and labour for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm, complete all as specified and as directed by Engineer-In-Charge.
S&F GI tubing 80mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as specified and as directed by Engineer-In-Charge.
Sona Enterprises
Rampal Singh Contractor
EESSI
KONCHOK TSEWANG
national engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .