Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40.3 L
EMD Value
₹80,500
Closing Date
24 Apr 2024, 6:00 pmClosed
GE GOLCOND
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
ADDN/ALTN AND SPL REPAIRS TO BUILDING NO E-76 FOR HOUSING OF SIMULATORS AT ARTY CENTRE HYD AND PROVN OF PARKING SHEDS FOR 12XTWO WHEELERS AND 04XFOUR WHEELERS AT OFFICE OF THE SQAE AT YEDDUMAILARAM UNDER GE GOLCONDA
2024_MES_647375_1
8743/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCOND
₹80,500
Yes
8 May 2024
21 Mar 2024
26 Apr 2024
21 Mar 2024
24 Apr 2024
10 Apr 2024
Amount
Dismantling of AC sheets / Galvolume sheet / GI Sheet of corrugated or semicorrugated etc. sheets in roof coverings complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick.(Below or above ground level) complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified
S & F for Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed.
S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Excavation in trenches not exceeding 1.5m in wide and n.exc 1.5 in depth foundation etc or for shafts, wells, cesspits, manholes, piers holes, etc n. exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L for PCC type D2 1:4:8 (40mm graded aggregates) in foundations, filling and mass Concrete complete all as specified and directed.
Returnng, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for DPC to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B-0 40mm thick complete all as specified and directed.
M & L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded complete all as specified and directed.
M&L for use & waste of rough finished flat Form work to sides of concrete foundations rafts, footing, base of columns, raft and raft beams, sides & soffits of foundation (if any) of foundation and plinth beams and similar work complete all as specified and directed.
M & L for reinforced Cement Concrete Type M-25(DESIGN MIX) using 20 mm graded granite stone aggregate) in foundations including rafts, footings, raft beam, plinth beams and mass concrete complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves incl supports etc for rough finished surface of concrete complete all as specified and directed.
M & L for reinforced Cement Concrete Type M-25 (DESIGN MIX) (using 20 mm graded granite stone aggregate) in Beams, cantilevers, roof beams, lintels over 1.5 M span complete all as specified and directed.
Use & waste of rough finished Square, rectangular or polygonal Form work to sides of pillars, posts, struts, columns and stanchions complete all as specified and directed.
M & L for reinforced Cement Concrete Type M-25(DESIGN MIX) (using 20 mm graded granite stone aggregate) in Columns, piers, posts and struts complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per Item No. 24 here in before but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specified and directed.
Extra over stone walling for 20mm hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for Rendering 15 mm thick in CM (1:4) on fair faces of stone surface of walls finished even and smooth w/o using extra cement complete all as specified and directed.
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of chalk whiting primer on newly plastered surfaces including 3mm thick wall care putty on wall including preperation complete all as specified and directed.
M&L for preparing Old stone masonry surfaces and applying a coats of cement based paint over on surfaces of walls complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified and directed.
M&L for 75 mm thick Plain cement concrete (1:2:4) type B2 (40mm graded stone aggregate) as in floorings finished surface even and smooth without using extra cement all as specified and directed.
S&F steel rolling shutter 1.25mm thick lath without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat ofprimer erected in position as indicated complete gear operated type with chain wheel and hand chain complete all as specified and directed.
Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-swhape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The kwork shall be carried out as per specifications, drawing complete all as specified and directed.
M&L for 40mm thick cement concrete (1:2:4) type B0 (12.5mm graded stone aggregate) as in sub-base and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for Plain cement concrete C-2 type 1:3:6 (40mm graded aggregate) 75mm thick as in plinth protection complete all as specified and directed.
M&L Vitrified Ceramic tiles, light shade, 10mm thick (Square or rectangular) polished, area of each tile not exc 0.36 Sqm in floors etc., and laid over and including cement screed bed or bedding layout in CM (1:6), 15mm thick and jointed in neat slurry and pointed in white or coloured cement to match using light shade coloured tiles complete all as specified and directed.
M&L Vitrified Ceramic tiles 10mm thick (Square or rectangular) light shade polished, area of each tile not exc 0.36 Sqm in skirting / dados etc and including 10mm thick rendering in CM(1:4) baking coat and jointed in neat slurry and pointed in white or coloured cement to match using light shade coloured tiles complete, all as specified and directed.
M&L 2nd class hard wood plain straight solid chowkats and frames wrought, framed, rounded, chamfered put together with glue pinned joints complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts of size25x3MM MS flat; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290-0 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in bed black for hold fasts and coping incl necessary form work weathering slightly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and directed.
M&L 2nd class hard wood plain framed factory made panel shutter 35 mm thick (two or three panels) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces, the size of rail & style as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35 mm thick IInd class hard wood glazed and skelton shutters sizes of members as specified in SSR(Part-I) clause 8.24(a), open rebated and prepared to receive glass or gauge (without sash bars ) edges of framing plain, chamfered or rounded, fitted with cut and miterd beads for securing glass or gauge etc. complete all as specified and directed .
M&L preparation of new surfaces of wood or wood based material description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F MS Butt hinges medium weight cold rolled of size 100mm complete all as specified and directed.
S&F MS barrel tower bolts of 200mm long stove enameled black with bright bolt complete all as specified and directed.
S&F MS pressed bow handle, oval type stove enameled black of size 150mm long complete all as specified and directed.
S&F mild steel sliding door bolts 300mm long plate stove enameled black with bright bolt not less than 12mm dia with and incl a minimum of 6 bolt and nut four on bolt plates and two on staple plate complete all as specified and directed.
S&F 300mm, ordinary Mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.0 mm & fixed with stainless steel wire staples fixed complete all as specified and directed.
S&F pre-coated box type steel windows or ventilators with side hung shutters including hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil puty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
Surface excavation n.exc 30 CM deep and averaging 15Cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and as directed.
Supply only integral water proofing compound (BIS Marked)
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of guage n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed including watering complete all as specified and as directed.
S&F MS Plain plates, square cut, with riveted, bolted or welded attachment Fe-410-W (Gde-E-250) quality A complete all as specified and as directed.
M&L for 40mm thick cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in flooring and finished surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating Eaves gutter half round 300 mm dia with union sockets & joints set in approved jointing compound GI based Plain steel sheet 0.70mm thick of any colour having tensile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws as specified as in eaves gutter complete all as specified and as directed.
S & F for mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm. but not exc 15cm complete all as specified and as directed.
S & F PVC (SWR) pipes 110mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall complete all as specified and as directed.
S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
M&L for river sand filling under floors including watering and consolidation complete all as specified and as directed.
M&L for Plain Cement Concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in coping/benching to manholes and drains including necessary formwork complete all as specified and directed.
M & L for 100mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified and as directed.
S & F 60 mm thick, machine made, Ist quality, precast cement concrete rubber moulded coloured interlocking paver blocks / tiles of triangular / zigzag / hexagonal / I in shape or shape and designe as approved with grey cement and pigment conforming to IS-15658-2006, M-35 grade laid over and including sand cushioning and the voids shall also be filled with fine sand complete all as specified and directed. Note: Sand will be measured and paid serperatley.
Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. complete all as specified and directed.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable(Phase & Neutral) and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/brick,masonary walls,roof etc including in new CI/MS sunk box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc complete all as specified and directed at site .
All as per Item No.71 above but one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed.
All as per Item No.71 above but for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches complete all as specified and as directed
All as per item No:71 but for One 3 pin 15 / 16 Amps modular switch socket outlet point on independent board with 4.0 sqmm PVC (FRLS) insulated sheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated sheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and as directed.
Supply and fix Switch socket outlet combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Supply and fix Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Supply and fix Ceiling rose surface bakelite three 65x50 mm, terminals 240 volts complete all as specified and as directed.
Supply and fix Electronic fan regulator stepped type with five step 240 volts suitable for 1200/1400 mm sweep AC ceiling fan complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32/40 A complete all as specified and as directed.
S&F in repairs Sheet metal enclosure Vertical distribution board suitable for incommer MCCB including 200 Amps bus-bar Three pole and neutral 415V, 4 Ways, double door complete all as specified and as directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TP/FP with 40 to 100 amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and current carrying capacity 5-32A in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S&F MCCB, FP, 415V, Fixed type 160Amps 36 KA complete all as specified and as directed.
M&L sub main wiring with Two single core PVC-FRLS insulated unsheathed multi stranded Submain wiring with three single core PVC (FRLS) insulated flexible copper conductor cable of size 4.0 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in and including PVC conduit medium grade with all fittings for concealed conduit complete all as specified and as directed. Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length
M&L sub main wiring with Two single core PVC-FRLS insulated unsheathed multi stranded Submain wiring with three single core PVC (FRLS) insulated flexible copper conductor cable of size 6.0 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including PVC conduit medium grade with all fittings for concealed conduit complete all as specified and as directed. ( For 6 AC Points) Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length
M&L sub main wiring with Four single core PVC-FRLS insulated unsheathed multi stranded Submain wiring with three single core PVC (FRLS) insulated flexible copper conductor cable of size 10.0 Sqmm and two single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings for concealed conduit complete all as specified and as directed. Note : (i) Three single core cable and one run of earth copper cable will be measured and paid as one unit length
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35sq mm 3.5 core complete all as specified and as directed.
Supply and spreading river sand in trenches for cables cushioning on top and bottom of cables all as specified. Note :- Punned thickness shall be measured and paid.
M&L brick protection with common burnt bricks sub class ‘B’ for cable protection complete all as specified and directed at site.
Palla Thrinatharao
SAI RAM CONSTRUCTIONS
Sri Lakshmi Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .