REPAIR/MAINT OF FIRE FIGHTING SYSTEM AND FIRE DETECTION AND ALARM SYSTEM IN TECH AREA AT AF STN GWALIOR
2021_MES_466584_2
8900/1321/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF TA GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹30,400
Yes
20 Nov 2021
23 Sept 2021
28 Oct 2021
23 Sept 2021
25 Oct 2021
30 Sept 2021
Amount
Carrying out periodical servicing and preventive maintenance of of fire fighting system, CO2 flood type of existing model & make: Fire-bell (fire fighting system, installed at ETB and fire alarm system with connected control wiring & panel at AF Station Maharajpur Gwalior) all as directed in order to maintain the fire fighting plants in functional and serviceable conditions complete all as and directed and follows. (i) The entire system shall be inspected & checked by the qualified technician at a interval of approx 6 months or as and when called upon to attend any breakdown maintenance and ensure complete serviceability of complete fire extinguishing sytem all as directed by Engr-in-Charge. Any refilling of CO2 gas or N2 gas etc shall be measured and paid under relevant items of this schedule as supply only here in after. The labour cost for fixing the spares shall be deemed to be inclusive of rate quoted in this item. (ii) All MS pipe line shall be inspected with respect to sefety purpose etc. (iii) Checking of the high pressure flexible hose pipes complete with connectors/adopters for CO2 connection to manifold as well as for pneumatic line between cylinders etc. (iv) Cleaning, oiling/greasing, servicing /overhauling of complete valves & fittings/assemblies. (v) Checking of the high pressure seamless cylinders of CO2 / N2 for their weight etc. and refilling of gas if found 10% less than the gross weight. (vi) Cleaning, oiling/greasing, servicing /overhauling of complete valves pneumatic actuator / valve of CO2 cylinders & fittings/assemblies. (vii) Checking of Non return valve of manifold and discharge hose and Cleaning, oiling/greasing, servicing /overhauling of valves. (viii) Cleaning, oiling/greasing, servicing /overhauling of all the nozzles of CO2 cylinders. (ix) All the manual call points and electronic hooters to be checked for normal functioning. (x) Checking of pressure release valve and Cleaning, oiling/greasing, servicing /overhauling of valves. (xi) All main fire control panel including battery & filling of distilled water/acid, smoke detectors, temperature heat detectors, connected control wiring etc. to be checked for normal functioning.
Periodical checking and servicing,testing of fire alarm system complete Conventional / Addressable at New ATC building single or multi stories having many No of detectors and accessories controled through one or more control panels of any loop for functiong of the purpose installed with all accessories, such as MCP, Hooter, Detectors etc for finding out defects if any and ensure serviceability complete all as specified and directed. Note: (i) All smoke/heat detectors shall be cleaned, serviced and checked for proper continuity and functionality. (ii) The system has to be checked for functioning by simulating smoke/heat etc to check automatic operation of fire alarm system. (iii) The contractor will submitt a certificate/ service report to this effect duly signed by technician and contractor all as directed.
All as per Sl item no.2.00 above but at CEO complex all as directed by Eng-in-Charge.
All as per Sl item no.2.00 above but at WSMT all as directed by Eng-in-Charge.
All as per Sl item no.2.00 above but at Old & New 10 tetra school all as directed by Eng-in-Charge.
All as per Sl item no.2.00 above but at 26 MMPU all as directed by Eng-in-Charge.
All as per Sl item no.2.00 above but at RDM all as directed by Eng-in-Charge.
All as per Sl item no.2.00 above but at FSP HD 1:1 all as directed by Eng-in-Charge.
Periodical servicing and preventive maintenance of fire fighting system at DWR including necessary testing as per fire fighting noms having one electric pumping set 60 HP , one No. of Diesel engine driven pumping set 2200 LPM and one no jokey pump of 15 HP 3 Phase having one control panel , interlock with each other in opration as per fire fighting System connected to sprinklar System , External fire hydrant system and controlled with fire detection system . The scope of work is as under :- (i) Checking the functionally System of fire pumping set (02 Nos ) for automatc operation and rectify if any fault either mechanical or electrical. (ii) Genral servicing of pumping sets including oiling , greasing etc. (iii) Genral servicing of sluice valves , nonreturn valves etc. (iv) Genral servicing of fire hydrant system . (v) Servicing of Diesel engine with replacement of oil filter , Diesel filter , engine oil , electrolyte etc . (vi) Cleaning & servicing of radiator. (vii) Reparing of foot valves etc including nut bolt and washers , automatically / mannually and making panel automatic functionally of all three pumping (viii) Repair of Electric panel for its functioning. Note:-The contractor will submit a service report duly indicating the state of functionality of each componets in the system signed by an authorized service Engineer.
All as per Sl item no. 9.00 above but fire fighting system at ATC all as directed by Eng-in-Charge.
All as per Sl item no. 9.00 above but fire fighting system at New Tacde hangers all as directed by Eng-in-Charge.
Material and labour for flushing out the complete pipe system from CO2 bank to gas nozzles with the adequate pressure of Nitrogen gas including taking out, opening and cleaning of nozzle complete all as specified and directed.
Supplying and filling of CO2 gas in existing empty high pressure seamless cylinders having 22.5 Kgs capacity after carrying to authorized filling station of CO2 gas and fixing back to the plant complete all as specified and directed. Note:- Cylinder shall be affixed with lamintated sticker of size not less than 100mmX75mm comprising of details of cylinder i.e. Total wt of cylinder, Nett wt. or filled gas & date.
Supply CO2 gas cylinder seamless of capacity 22.5 kg or nearest higher size conforming to relevent IS code with control valves etc duly filled with CO2 gas all as specified and directed .
Supplying and filling of Nitrogen (N2) gas in existing high pressure seamless cylinders having 2 Kgs capacity after carrying to authorized filling station of N2 gas and fixing back to the plant complete all as specified and directed.
Supply N2 gas cylinder seamless of capacity 2 kg or nearest higher size conferming to relevent IS code with control valves etc duly filled with N2 gas all as specified and directed .
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved colour complete all as specified and directed.
M & L for preparation of the old existing steel surfaces of CO2 Gas cylinder and applying two coats of synthetic enamel paint of approved colour complete all as specified and directed.
Supply and fixing in repair 80mm bore MS pipe class 'C' heavy duty with Seamless welding including required MS fittings & testing complete all as specified and directed.
Supply & fixing in repair brass discharge nozzles, cone type, for CO2 cylinders of approved make complete all as specified nd directed.
Supply & fixing in repair high pressure flexible hose pipe10 Kg /cm2 with flexible hose pipe flexible connector for pneumatic line & cylinder of approved make complete all as specified and directed .
Supply & fixing in repair high pressure flexible hose pipe 10 kg/cm2 with flexible hose pipe flexible connector for cylinder to cylinder of approved make complete all as specified and directed.
Supply only high pressure, brass ISI mark, non return valve 20mm bore for manifold and discharge hose connection of approved make complete all as specified and directed. Note: The cost of fixing is deemed to be included in rate quoted under Item No 1.00 here-in-before.
Supply only solenoid valve 60Kg/cm2 pressure two way 15 mm dia (ISI mark) including all fitting complete all as specified and directed. Note: The cost of fixing is deemed to be included in rate quoted under Item No 1.00 here-in-before.
Supply only high pressure brass safety valve 25mm bore (ISI mark) with outlet pipe of approved make complete all as specified and directed. Note: The cost of fixing is deemed to be included in rate quoted under Item No 1.00 here-in-before.
Supply, fixing in repair including testing and commissioning of Detector complying with and type certified to EN 45 addressable type, multisensor detector with heat and smoke combination with base complete ofexisting make to match with make of control panel all as specified and directed.
Supply & fixing in repair including testing and commissioning of Intelligent Wall Mounted Sounder of existing make and colour of control panel complete all as specified and directed .
Supply, fixing in repair including testing and commissioning of Fire alrm system wiring using three single core PVC insulated, sheathed stranded copper conductor cable of size 1.5 Sqmm 1100 Volts drawn in and including PVC conduit (Medium grade ISI marked) of dia not less than 20mm with standard accessories complete all as specified and directed .
Supply and fixing of maintenance free battery of 12 volts 7 AH capacity and connecting and testing at site complete all as specified and directed including disconnecting and taking off exisitng unserviceable battery.
Supply & fixing in repair including testing and commissioning of Fire alrm Control panel complying with BSEN54 addressable two loop panel of capacity from 99 detector and 99 modules upto 200 detector and modules complete with battery 12 volts 7 AH capacity (02 Nos ) all as specified and directed Make :- GST/System Sensor/Agni devices
Supply & fixing in repair including testing and commissioning of addressable / conventional manual call point (MCP) surface mounting with glass cover complete all as specified and directed.
Supply & fixing in repair including testing and commissioning of Auto Dialer system complete all as specified and directed.
Programming/re-loading of software for existing unserviceable fire alarm control panel to make it functional with the help of software to suit existing panel/model including testing of all connected circuits/detectors complete all as specified and directed.
Supply & fixing in repair Pneumatic actuator suitable for cylinder valve (ISI mark) operating at 15 to 30 Kg/cm2 complete all as specifiec and of approved make.
Supply & fixing in repair Butter Fly Valve 150 mm CI Lever operated pressure /Class /Rating PN-1.6, Water type Nitrile Rubber Lining SG Iron (Make: Sant ,Castral, Kartar) ISI Marked .
All as per Sl item no. 35.00 above but butter fly valve 100 mm dia all as directed by Eng-in-Charge.
All as per Sl item no. 35.00 above but butter fly valve 80 mm dia all as directed by Eng-in-Charge.
Supply Hose Reel Drum with 30mtr Flexible pipe 25mm Dia and Shut off Nozzle Make :New Age ,Min Max Mtech :ISI Marked.
Supply and fix in repairs single Hydrant Gun Matal 63mm Dia with Water Tigghtness test :-14kgf/cm2 and Hydrostatic Test :- 21kgf/cm2 and Flow test :90 LPM min at :7kgf/cm2 .LPMm (Make :New Age ,Min Max Mtech )ISI Marked.
Supply RRL Hose pipe 63mm Dia 15mtr Gun Metal Male/Female Coupling with working pressure : 200 PSI Test Pressure: 300 PSI and Burst Pressure :500 PSI . (Make :New Age ,Min Max ,M Tech ) ISI Marked.
Supply RRL MS Hose Box size 900/750/250 Double Door . (Make :New Age ,Min Max ,M Tech ) ISI Marked.
Supply and install in repair Carbon -Di-Oxide (CO2 ) Portable Fire Extinguisher capacity 4.5 Kg MS Seamless body ISI With Gun mattle Valve . High Pressure Horn type Hose pipe ,with Syphan ,95% Min Efficitive Discharge ,Operation valve Upright Wheel / Squeeze Grip type (Make : Like Gurd , Safex )
Suppy and install in repair ABC type Powder filled Fire Extinguisher capacity 4 kg IS 15683 ,85% Mon effective Discharge , 13 Sec Discharge Time ,35 kgf /cm2 Hydraulic tested Pressure . (Make : Like Gurd , Safex )
M&L for rewinding of electric motor of capacity 50 to 60 HP with super enamelled copper winding wire of same gauge and turns to maint desired RPM including necessary insulating meterials , varnishing and transportation to work shop and bring back to orginal location and installatin testing and commissioning etc complete all as specified and directed.
M&L for rewinding of electric motor of capacity 15/20 HP with super enamelled copper winding wire of same gauge and turns to maint desired RPM including necessary insulating meterials , varnishing and transportation to work shop and bring back to orginal location and installatin testing and commissioning etc complete all as specified and directed.
A K BANSAL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .