Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.9 L+₹43,111.64 (4.12%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹12.6 L+₹2.1 L (19.9%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹12.6 L+₹2.1 L (20.1%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹13.1 L+₹2.6 L (25.2%)Rejected-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
GE(S) Jaipur, MES, Kalyan Marg, Bani park, Jaipur-302006
Repair maint of LT OH/UG circuit and switch gears, panels board and other connected accessories at Zone III area bhankrota Jaipur Mil Stn under GE(S) Jaipur
2021_MES_444899_1
GE (S)J-01P/2021-22 8648/ /E8
Open Tender
Civil Works
Item Rate
180 days
Jaipur
Class E Category b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹36,000
Yes
15 Jun 2021
22 May 2021
5 Jun 2021
22 May 2021
3 Jun 2021
29 May 2021
22 May 2021 - 25 May 2021
60 days
Amount
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil
All as per item No.1 above but depth exc 1.5 M but n.exc 3.0M in depth.
M & L Sand cushioning to under ground cable with tibba sand and punning to provide a required cover.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
M & L Dismantling of existing Unsv ACSR conductor of any size from insulators fixed on poles as directed by Engineer-in-Charge.
M & L Dismantling of prestressed cement concrete poles complete of any size including PCC foundation and necessary excavation & earth work and making good to distubed surfaces as directed by Engineer-in-Charge
M & L Dismantling and taking down existing LT insulators of any type and size as directed by Engineer-in-Charge.
M & L Dismantling of existing stay assembly of any type & size complete including excavation and earth work and demolition of concrete and making good to distubed surfaces as directed by Engineer-in-Charge
M & L Dismantling of cross arms, bracing, supports, clamps, nuts and bolts of mild steel channel or angle sections etc complete as directed by Engineer-in-Charge
Dismantling/taking out old defective LT UG cable from trench/ on walls/poles/ducts etc of following sizes:-
16 Sqmm, 2 core to 25 Sqmm 4 core
35 Sqmm, 3.5 core to 95 Sqmm 3.5 core
120 Sqmm 3.5 core
M&L pre-stressed cement concrete poles, 9.0 metre long with minimum cross section 102 mm x 172 mm at top and minimum cross section 102 mm x 279 mm at bottom, class-10, conforming to IS-1678. complete all as specified and directing.
M&L stay assembly complete with accessories as shown in electrical plate No. 1 of MES SSR part I, including stay rod of 20 mm dia, MS stay plate 300 mmx500mmx6mm & GI stay wire of 7/8 SWG, bow, PCC 1:3:6 of suitable length as required.
M&L cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section including bolts, nuts, washers, welding, bending (cold or hot) drilling holes for bolts any shape or size as indicated or directed and inclusive painting with one primer coat of zinc chromate and two coats of aluminium paint. Note :- MS/GI clamps, bolts, nuts and washers will also be measured under this item.
M&L pin type, porcelain, vitreous brown, white or green insulator 100 mm height and 65 mm dia, 1100 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete conforming to IS.
M&L shackle type, porcelain, vitreous, brown, white or green insulator 1100 volts grade of 90 mm dia and 75 mm height including galvanised MS strap of 31 mm x 3 mm size, 12 mm dia insulator bolts, washers and nuts, complete, conforming to IS.
M&L for aluminium conductor steel reinforced (ACSR) straining properly on insulator and binding with aluminium binding/ Clamps, for running lines or jumpers etc.of any type and sizes complete all as specified and directed by Engineer-in-charge. Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
M & L Straining only existing ACSR of any size/span on existing poles, insulators using proper tensioners and binding with aluminium binding/ Clamps complete as directed by Engineer-in-Charge. (each length of single conductor measured separately) Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
Supply and lay GI pipe Light grade fixed on poles, walls and ceiling etc. with all fittings for protection of cable in repairs of following dia. (Clamps for fixing shall be measured and paid seperately)
M & L for boring under road/drain by manual/machine method for inserting GI tubing up to 80 mm dia for cable protection all as specified and directed by EIC.
M&L earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GI medium grade. The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I. Note - The value of earth resistance of pit shall be less than 3 Ohm.
M&L for Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m all as directed by Engineer-in-Charge.
Supply, lay & testing LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strip armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc of following sizes:-
120 Sqmm, 3.5 Core
95 Sqmm, 3.5 Core
70 Sqmm, 3.5 Core
50 Sqmm, 3.5 Core
35 Sqmm, 3.5 Core
25 Sqmm, 4 Core
16 Sqmm, 4 Core
16 Sqmm, 2 Core
M&L for scrapping & preparation of old steel surface of LT Panel of any type and M&L for painting the same with two coats of synthetic enamel paint by spray of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fix heat shrinkable straight through jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of following sizes:-
10 - 35 Sqmm 3½ Core
50 - 70 Sqmm 3½ Core
95 - 150 Sqmm 3½ Core
185 Sqmm 3½ Core
400 Sqmm 3½ Core
Supply and fix heat shrinkable end jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of following sizes
10 - 35 Sqmm 3½ Core
50 - 70 Sqmm 3½ Core
95 - 150 Sqmm 3½ Core
185 Sqmm 3½ Core
400 Sqmm 3½ Core
Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB of undermentioned amp and breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase, adjustable type including extension terminals and Ics=100%Icu connecting using suitable fasteners, modification/fabrication if any complete all as required at site, as specified and directed:-
63 amp, 16/18 KA, 4 pole
100 amp, 16/18 KA
125 amp, 16/18 KA
160 amp, 35/36 KA
200 amp, 35/36 KA
250 amp, 35/36 KA
400 amp, 50 KA
S&F of Danger notice plate of 1.6 mm thick mild steel sheet 20x15 cm size, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with suitable MS clamps, bolts and nuts including taking down complete all as specified and directed.
Disconnecting & taking out the existing Unserviceable LT panel and S&F new out door (Kiosk type) type LT panel, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 200 Amp, 35/36 KA, 415 volts, thermal release, adjustable type (Ics=100%Icu) as incomer and one on-load changeover switch, 4 pole, 415 Volts, 200 Amps & Aluminium bus bar 400 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and directed by Engr-in-charge.
S&F Bus bar electrolytic grade aluminium of 25×6 mm, mounted on insulators including drilling holes including disconnection & reconnection of cables from existing panel complete all as specified and directed.
S & F On-load change over switch, 4 pole, 415 volts, suitable of following cap for existing panel including taking down the unsv c/o switch, disconnecting and reconnecting all electrical connections, modification/fabrication if any complete all as specified and directed.
S & F in repair Off-load manual change over switch 4 pole, 415 volts, 100 amp in sheet steel enclosure, factory made including disconnecting and reconnecting all electrical connections complete all as specified and directed.
S&F in repair LED indicating lamp (Set of three lamps, RYB), 240 volts AC including necessary wiring
S&F in repair Red luminous push button complete all as specified and directed by Engr in Charge.
S&F in repair Green luminous push button complete all as specified and directed by Engr in Charge.
M&L for cutting/removing damaged Hinge of any size and welding/ fabricating same with best quality replacement spare in the existing panel including making good of existing surface
M/L for cutting/removing damaged Sheet steel including painting with two coats of synthetic enamel paint over a coat of primer and fixing to the part, it will dismantle upto the satisfaction of Engr-in-Charge.
Repairs & Maintenance of APFC panel of capacity 25 KVAR to 150 KVAR including replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter complete. Note : Unserviceable Spare Parts will be measured & paid separately under respective items of Schedule ‘A’.
Supply only power capacitor cylindrical type suitable for existing APFC panel complete incl removal of old unsv capacitor all as specified and directed by Engr in Charge of following capacity:-
Supply and fix in repair capacitor duty contactor , AC coil complete all as specified and directed by Engr in Charge for following capacity:-
S&F in repairs APFC relay 12 stage with suitable CT complete all as specified and directed by Engineer in Charge.
S&F in repairs MCB TP , 10 KA breaking capacity of following sizes complete all as specified and directed by Engr in Charge.
S& F in replacement cable junction box of size 260x210x116mm for outdoor installation IP-65 protected made of poly carbonate with necessary clamps (2 Nos) for mounting on poles, comprising with copper bus bar for 3 phases and neutral of required amps capacity for cable size 16/35 sqmm 4 core, phase and neutral fixed on porcelain insulator and MCB, SP 6 to 25 amps, 10 KA - 01 Nos complete including taking down old unsv junction box complete. Make- Hensel cat part K8350 or equivalent in Sintex/ legrand/indokop.
M&L for PCC (1:3:6) type C2 with 40 mm stone aggregate for base / foundation / earthing chamber / chamber cover including form work complete all as directed by EIC
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete.
M&L for fault finding in U/G cable using fault locating machine on requirement for LT/HT cables of any type/size complete all as specified and directed by Engr-in charge.
S&F cable route indicator, cast iron 10 cm dia with 25x25x4 mm angle iron 0.8 m along the LT/HT cable trench including painting and grouting in ground in PCC 1:2:4 type B1 using 20 mm graded aggregate complete all as specified and directed by Engr in Charge.
M&L for shifting of LT Panel from one location (within the electrical zone) to another location including making all electrical connections as well as PCC foundation completely as specified and directed by Engr-in-Charge. Note:-Excavation & related earth work shall be inclusive of quoted rates.
SHREE BHAGWATI ENTERPRISES
M/S Sheeba Enterprises
M/s Radhey Enterprises
AUTOMATION AND SWITCHGEAR PANELS
Stuti Trading Company
SM CONSTRUCTION COMPANY
M/S Anil Enterprises
Adhara Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .