Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85,226Accepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹90,390+₹5,164 (6.06%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹93,575+₹8,349 (9.80%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹98,806+₹13,580 (15.9%)Accepted-Finance | L4 | Accepted-Finance OK |
Tender Value
Refer Docs
EMD Value
₹3,327
Closing Date
17 Aug 2020, 3:00 pmClosed
Executive Engineer (Elect) KBN
T.E. Building KBN, Room No -19, Kidwai Bhawan MTNL, New Delhi-110001
Providing Electrical Works at GM (SS) unit, 7th floor Kidwai Bhawan ,MTNL,ND
2020_MTNL_576649_1
EE(E)KBN/2020-21/10-08-2020/36
Open Tender
Electrical Works
Item Rate
15 days
Kidwai Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
MTNL Delhi
₹3,327
22 Aug 2020
10 Aug 2020
18 Aug 2020
10 Aug 2020
17 Aug 2020
10 Aug 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group C
Supplying and drawing following size of FRLS PVC insluated copper conductor, single core cable in existing surface / recessed steel/ PVC conduit/PVC chanel as required. a) 3 x 1.5 sqmm
b) 3 X 4 sqmm
c) 3 x 6 sqmm
Supplying and installing following size of perforated pre-painted M.S. cable trays/Bends/ Reducers/ Tee's Cross members with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required (a) 150 mm width X 50 mm depth X 1.6 mm thickness(cable trays)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess/ wooden partions including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required(a)20 mm
S/F following sizes / modules surface/recess mounting GI box along with modular base & cover plate for modular switches in recess/surface/wooden/ply board etc as reqd.(M/S ANCHOR/ LEGRAND/ L&T/WIPRO/ NORTH-WEST/ SCHNEIDER OPALE/CRABTREE/MK/SIEMENS/Havells/cona a) 1 or 2 Module
b) 3 modules
c) 8 modules
d)12 module
S/F HYLAM sheet to cover existing board i/c cutting fixing with screws as reqd.
S/F following modular switch / socket on the existing modular plate & switch box including connections but exlcuding modular plate etc as reqd. Make M/s ANCHOR(ROMA)/ LEGRAND/ L&T/WIPRO/ NORTH-WEST/ SCHNEIDER OPALE/CRABTREE/MK/SIEMENS/Havells/Cona a) 5/6 amps switch
b) 15 / 16 amps switch
c) 5 pin 5 / 6 amps socket outlet
d) 6 pin 15 / 16 amps socket outlet
e) Indicator
S/F 16" sweep single phase 230 volts wall fan complete with all accessories i.e. fan blade, capacitor and fixing on wall connection earthing as reqd.(Make M/S CROMPTON/USHA/ HAVELLS/ / ALMONARD/ ORIENT make)
Supplying and fixing following rating “C” curve MCB in the existing SDBs connections complete as reqdM/s HAVELLS /LEGRAND/ L&T /SCHNEIDER / ABB a)6 amps. to 32 amps. ratings , SP MCB 10 KA breaking capacity
b) 63/100 amps DP isolator
C)16/25 A SP modular MCB
Supplying, installation, testing and commissioning of recess mounting indoor LED fitting of size 600mm X 600mm (NS) complete with CRCA housing, diffuser, electronic driver etc. operated on 230 Vold 50 Hz AC supply having power consumption 30 -36 Watt including fixing the fitting on existing false ceiling by direct /with 2 Number metal chain as per site requirement including making suitable opening / modification in the false ceiling to accommodate the fitting as per site requirement and making connections with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. complete with all accessories etc as reqd. (Make: Havells, Cat No. 34W 840 2X2 LHEWEJP6PL1W034, Philips Cat No. RC380B G4 or equvillent model in Osram/Crompton/Bajaj/Syska
Supplying and fixing 12 way SPN double door ,DBs 230 volts with copper bus bar din bar and suitable for provision for DP MCB / isolator as in commer and SP MCBs as outing ,neutral link earthing the body connections complete as reqd.(M/S MDS /Havells/L&T/ABB/Schneider make)
Supplying followig rating copper conductor XLPE armoured power cable of 1.1 KV grade on wall / cable tray i/c connection etc as reqd.(ISI marked) a) 2 core 16 sqmm
S/M end termination with brass compression gland copper lugs for following size XLPE / armoured power cable of 1.1 KV grade as reqd.b) 2x 16 sqmm copper
P/F 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface /recessed conduit/ submain / cable as reqd.
S/F 4 feet LED Batten fitting with integral electronic driver and LED tube operated on 230 V 50 Hz AC Supply on surface with mounting arrangement connections etc complete as reqd (System wattage 20-22 W system, lumen output-1850-2000 lumens etc) Make-Philips,Osram, Havells,Bajaj,Syska
P/F LED engagement light fitting with LED Bulbs (0.5 w to 5 W) i/c 2 Nos lamp holder with Red green display arrangement etc on wall /surface etc as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Dismantling of existing light fitting /fans/wirings/DB's/Switch boards/conduits/PVC channels and shifting it to store room as per the instruction of engineer in charge etc as reqd
KASHYAP ELECTRICALS
Rawat Enterprises
Star Electric Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .