Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹42.4 LAccepted-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹42.6 L+₹21,489 (0.51%)Rejected-Finance | L-2 | Rejected-Finance Other than L-1 | |
| 3 | L-3₹44.7 L+₹2.3 L (5.50%)Rejected-Finance | L-3 | Rejected-Finance Other than L-1 | |
| 4 | L-4₹45.4 L+₹3.0 L (7.18%)Rejected-Finance | L-4 | Rejected-Finance Other than L-1 |
Tender Value
₹47.9 L
EMD Value
₹95,780
Closing Date
1 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI DIGVIJAY CHAUHAN
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR OF BLDG NO NP-04 AND NP-06 (OR MD ACCN) AT JNE OF EME BN (COMD) UNDER GE (NORTH) UDHAMPUR
2021_MES_459574_1
CWE/U(N)-37/2021-22
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹95,780
Yes
28 Oct 2021
14 Jul 2021
8 Sept 2021
14 Jul 2021
1 Sept 2021
20 Aug 2021
60 days
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peepal tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
5mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished even and smooth without using extra cement as in slabs facias, chhajjas and the like, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per srl item No 6 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 8 above but frame size 105 x 60 mm.
BLANK
2nd class hardwood glazed and skeleton shutter open rebated and prepared to receive glass/ gauge etc with rebated sash bars any number of edges of framing plain chamfered and rounded fitted with cut and metered beads and screwing glass etc size of the shutter as specified in SSR Part - I Section ' 8 ' clause 8.24 ( a ) complete.
Providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling as in the pressed steel door frame/hold fast complete all as specified.
Factory made (box type) mild steel ventilators glazed and gauzed shutters with side hung including pintol hinges, steel peg stay , locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified. Note : i) The ventilators shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per srl item No 14 here in before but without glazing bar complete all as specified and as directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290 Gde-E-165, complete all as specified and as directed.
Providing and fixing 30mm thick factory made PVC door shutter consisting of panel of Hollow PVC Profile of 24mm thickness, consisting of frame made out of M.S tubes of 19 gauge thickness and size of 19mmx19mm inserted inside the hollow section of stiles, top and bottom rails and two 19mmx19mm MS tubes inserted horizontally inside the hollow profile section at an equal distance from top and bottom of door and fixed with hollow profile section using 3mm thick Prelam PVC sheet using screws. Hollow PvC profile shall be lipped with 10mm (5mmx2) thick x 24mm width on stiles and rails using solvent cement. The inner panel shall be laminated with 5mm thick termite proof, water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of the panel etc complete all as specified.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
3 mm thick figured glass, pin head type, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old wooden or wood based surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint , complete all as specified.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
75mm butt hinges ,medium weight ,cold rolled mild steel all as complete all as specified and directed.
100 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
Aluminium alloy, anodised, latch with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete and fixed length of bolt 150mm complete, all as specified.
150 mm long, mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engr-in- Charge.
150 mm long, mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engr-in- Charge.
300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engr-in-Charge.
Mild steel, 150 mm, ordinary rat tail rod pattern door spring including roller and roller plate including welding to steel frame complete all as specified.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. including P or S trap complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, float and handle including brackets with twin flush provision and 32 mm flush pipe of polythylene ball valve, complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified.
Description all as per srl item No 40 above but in vertical surfaces like dado/skirting as in riser of steps and pillar etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering (backing) on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Green marble slab 18-20 mm thick in shelves machine cut as in shelves, cupboard, etc. bedded jointed and pointed with grey cement slurry including cutting and polishing ,rounding edges, complete all as specified.
Glazed coloured ceramic tiles 450mm x 300mm x 7 to 8mm on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
6mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber /GI/Aluminium framework with screws, complete all as specified and as directed by Engr-in-Charge.
Anodised aluminium snap grid frame work for false ceiling, complete all as specified and as directed by Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Preparing plastered or unplastered new surfaces of walls and applying two coats of cement base paint, over a coat of cement primer and 1 mm thick a layer of wall care putty complete all as specified and as directed by Engr-in-Charge.
Complete removal of old decorated surfaces of wall, chajjas, etc. including brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying one coat of cement base paint, over a coat of cement primer and 1 mm thick a layer of wall care putty complete all as specified and as directed by Engr-in-Charge.
Preparing of old decorated surfaces of wall, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying one coat of white wash on walls surfaces, complete all as specified and as directed by Engr-in-Charge.
Description all as Srl item No 53 above but on ceiling surfaces.
Applying three coats of white wash on newly plaster surfaces of wall over including preparation of surfaces complete all as specified and directed.
Description all as Srl item No 55 above but on ceiling surfaces.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty and including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
M&L for mild steel steel TMT bars 6mm to 8mm dia and over cut to length bent to shape reqd incl cracking bending spirally for hoping columns hooking ends and binding with mild steel wire annealed not less that 0.9mm dia all as specified.
S&F Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes, complete all as specified and as directed by Engr-in-Charge.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, any size jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 67 above but except pipe.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 69 above but except pipe .
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 71 above but 75 mm bore pipe.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4), complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single/double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Description all as per item No 74 above but 75 mm bore .
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 100mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed.
Description all as per item No 77 above but 75 mm bore .
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Peg set of six,mild steel, fancy type, complete all as specified and as directed by Engr-in-Charge.
100mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base to floors and the like, complete all as specified and as directed by Engr-in-Charge.
Factory made machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 30 mm thick sand cushioning bed including spreading levelling watering if required, Shape and size of pavings shall be approved by Engr-in-Charge.
Providing, pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in kerb stones and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe-290 Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
35mm thick factory made flush shutters, solid core construction, with block board core and plywood face pannels and one face is covered with decorative face veneer with liping/frame to match, complete all as specified and directed by Engineer-in charge.
18/19mm thick Prelaminated particle board, termite proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Hasp and staple, 100 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, all as specified .
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
Soap dish fancy type chromium plated fixed with brass screws and wooden/plastic cleats complete all as specified.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10cm and not exceeding 20 cm girth complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Brass chromium plated shower rose 125mm size with arms, round shape, swivel type, Chrome plated fixing in repair, complete all as specified.
Angle valves, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm with adjustable flanges, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F 25 mm dia MS powder coated antique type curtain rods with bracket fixed to wall with suitable screws and onion type end brackets all as per approved design/colour/pattern, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including concrete bedding and haunching complete all as specified and as directed by Engr-in-Charge.
Concrete bed to drain pipes of 150mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregates, complete all as specified and as directed by Engr-in-Charge. NOTE: Thickness of bed is 10 cm and width of bed is 30 cm plus external dia of pipe.
150mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed with span yarn, complete all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Cement concrete tiles 25cm x 25cm and 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and in floors, and cut and polished , over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15/20/25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
25 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 111 here-in-before but for one bell/buzzer controlled by one push button on the independent board complete all as specified and as directed
Description all as per srl item No 111 above but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 111 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 111 above but for light point controlled by 2-two way switch
Description all as per srl item No 111 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Switch piano , single pole, one way ,5 Amp, complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole two way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,with all acessories, complete all as specified and as directed by Engr-in-Charge.
Bell push 5 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 4/5 Watt LED with integral electronic driver complete making all connection using 1.5 sqmm Copper conductor multistranded PVC insulated 2 core flexible cable in white colour from ceiling rose to fitting and testing after fixing complete all as specified and all directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver completemaking all connection using 1.5 sqmm Copper conductor multistranded PVC insulated 2 core flexible cable in white colour from ceiling rose to fitting and testing after fixing complete all as specified and all directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Taking down ceiling fan/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging all as per the directions of Engg-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 129 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down old serviceable/ unserviceable MCB/ DB of any type and capacity with MCB etc after disconnecting for reuse for credit , complete all as specified and as directed by Engr-in-Charge.
Re-fixing only,serviceable MCB/DB of any type and capacity with MCB as obtained against item No 131 complete including minor repair to existing fitting occure while dismantling, complete all as specified and as directed by Engr-in-Charge.
Sheet metal TPN DBS -DPX3 160 MCCB DBS 04 way ( DPx3 250 + 12 ) with metal door 415 volts grade IP 43 protection grade fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr - in - Charge and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole, 415 volts 160 Amps with breaking capacity 16 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 40 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Re-fixing only,serviceable MCB SPN/SP of any type and capacity obtained against srl item No 135 and 136 all as specified and as directed by Engr-in-Charge.
Taking down old serviceable/ unserviceable Electric meter including meter box from existing position carefully refixing including making good to disturbed surfaces , complete all as specified and as directed by Engr-in-Charge.
Re-fixing only,serviceable Electric meter including meter box as obtained against srl item No 138 complete including minor repair to existing fitting occure while dismentling, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making all connection using 1.5 sqmm Copper conductor multistranded PVC insulated 2 core flexible cable in white colour from ceiling rose to fitting and testing after fixing complete all as specified and all directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output completemaking all connection using 1.5 sqmm Copper conductor multistranded PVC insulated 2 core flexible cable in white colour from ceiling rose to fitting and testing after fixing complete all as specified and all directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
New generation energy saving and environmental friendly long life LED street light of 25 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making all connection using 1.5 sqmm Copper conductor multistranded PVC insulated 2 core flexible cable in white colour from ceiling rose to fitting and testing after fixing, complete all as specified and all directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
M/s LAL DAYAL CONSTRUCTION CO
RAMAN KUMAR
paras ram pachiala
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .