Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹39.4 L+₹48,855 (1.26%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.5 L+₹56,705 (1.46%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.8 L+₹94,919 (2.44%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.5 L+₹3.6 L (9.29%)Rejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | Singh Associates L4 | RUCHIKA ENGG.WORKS L3 | RefAir Technical Services L2 | P S TRADERS L7 | Shiv Enterprises L6 | SNOWY ENGINEERING INC L1 | PANWAR ELECTRICALS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply Installation,Testing and commissioning of 100% Inverter VRF Modular units complete with Inverter Scroll compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated, Conformal Coating on PCB, Hydrophilic Blue Fins, Twin Accumulator & Two Compressors in each Outdoor Unit. All units are Cooling & Heating both with Eco Friendly Refrigerant (R-410a). Unit should deliver 100% capacity without deration upto 43°C Ambient Temperature.Operating Outdoor Ambient Temperature Range Cooling 10°C to 56°C & for Heating -10°C to 24°C.IPLV should be more than 6.7. VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. All Drawings & Heat Load should be Vetted through OEM only. Make: O-General, Mitsubishi, Bluestar | ||||||||||
| 1.01 | 16HP | 1 | Each | 3,54,000 ₹3,54,000 Lowest | 5,19,200 ₹5,19,200 | 5,90,000 ₹5,90,000 | 6,60,000 ₹6,60,000 | 5,75,000 ₹5,75,000 | 4,50,000 ₹4,50,000 | 6,00,000 ₹6,00,000 |
| 1.02 | 12HP | 1 | Each | 2,95,000 ₹2,95,000 Lowest | 4,29,520 ₹4,29,520 | 4,75,000 ₹4,75,000 | 4,70,000 ₹4,70,000 | 4,60,000 ₹4,60,000 | 3,55,000 ₹3,55,000 | 5,00,000 ₹5,00,000 |
| 1.03 | 24HP | 1 | Each | 4,64,500 ₹4,64,500 Lowest | 6,78,500 ₹6,78,500 | 7,71,000 ₹7,71,000 | 6,50,000 ₹6,50,000 | 7,60,000 ₹7,60,000 | 5,95,000 ₹5,95,000 | 8,00,000 ₹8,00,000 |
| 2.00Supply installation,testing and commissioning of Cassette Units with evaporator coil,fan and Fan motor, with cordless remote control, Drain Pump and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required.The units shall be of following capacities. Make: O-General, Mitsubishi, Bluestar | ||||||||||
| 2.01 | 3.2Tr(1095CFM) | 6 | Each | 50,858 ₹3,05,148 Lowest | 62,000 ₹3,72,000 | 60,500 ₹3,63,000 | 1,40,000 ₹8,40,000 | 71,900 ₹4,31,400 | 62,000 ₹3,72,000 | 60,000 ₹3,60,000 |
| 2.02 | 2.8Tr (945CFM) | 5 | Each | 50,032 ₹2,50,160 Lowest | 60,000 ₹3,00,000 | 60,000 ₹3,00,000 | 75,000 ₹3,75,000 | 70,000 ₹3,50,000 | 60,000 ₹3,00,000 | 58,000 ₹2,90,000 |
| 2.03 | 1.7Tr (695CFM) | 3 | Each | 43,660 ₹1,30,980 Lowest | 50,000 ₹1,50,000 | 55,000 ₹1,65,000 | 75,000 ₹2,25,000 | 62,000 ₹1,86,000 | 52,000 ₹1,56,000 | 51,000 ₹1,53,000 |
| 3.00 | S & F refrigerant Y-Joint for Combining Outdoor and Indoor Units required for distribution of refrigerant in copper piping as per final approved drawing which will be submitted by OEM . Make: O-General, Mitsubishi, Bluestar | 14 | Each | 4,000 ₹56,000 Lowest | 5,890 ₹82,460 | 6,500 ₹91,000 | 11,500 ₹1,61,000 | 7,500 ₹1,05,000 | 6,800 ₹95,200 | 9,000 ₹1,26,000 |
| 4.00Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of following sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping install on cable trays(as per shedule item no 10) with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed: - Make:Mandev, Maxflow, Rajco | ||||||||||
Tender Value
₹49.9 L
EMD Value
₹99,880
Closing Date
4 Nov 2025, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
SPL REPAIR REPLACEMENT OF BER AC PLANT OF 3 X 15 TR AT COD UNDER GE (U) PM DELHI CANTT-10
2025_MES_735058_1
GE(U)/PM/D-50/2025-26
Open Tender
Miscellaneous Works
Item Rate
120 days
Delhi Cantt
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹99,880
Yes
5 Jan 2026
14 Oct 2025
6 Nov 2025
14 Oct 2025
4 Nov 2025
28 Oct 2025
Amount
Supply Installation,Testing and commissioning of 100% Inverter VRF Modular units complete with Inverter Scroll compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated, Conformal Coating on PCB, Hydrophilic Blue Fins, Twin Accumulator & Two Compressors in each Outdoor Unit. All units are Cooling & Heating both with Eco Friendly Refrigerant (R-410a). Unit should deliver 100% capacity without deration upto 43°C Ambient Temperature.Operating Outdoor Ambient Temperature Range Cooling 10°C to 56°C & for Heating -10°C to 24°C.IPLV should be more than 6.7. VRF Installation work to be execute by OEM or OEM Authorised Vendor Only. All Drawings & Heat Load should be Vetted through OEM only. Make: O-General, Mitsubishi, Bluestar
Supply installation,testing and commissioning of Cassette Units with evaporator coil,fan and Fan motor, with cordless remote control, Drain Pump and necessary accessories etc suitable for operation on 230 V +- 10% 50 Hz single phase AC supply complete as required.The units shall be of following capacities. Make: O-General, Mitsubishi, Bluestar
3.2Tr(1095CFM)
2.8Tr (945CFM)
1.7Tr (695CFM)
S & F refrigerant Y-Joint for Combining Outdoor and Indoor Units required for distribution of refrigerant in copper piping as per final approved drawing which will be submitted by OEM . Make: O-General, Mitsubishi, Bluestar
Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of following sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping install on cable trays(as per shedule item no 10) with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed: - Make:Mandev, Maxflow, Rajco
9.5 mm with 13 mm thick insulation
12.7 mm with 13 mm thick insulation
15.9 mm with 13 mm thick insulation
19.1 mm with 13 mm thick insulation
28.6 mm with 19mm thick insulation
34.9 mm with 19mm thick insulation
34.9 mm with 19mm thick insulation
Supply and fixing in position the 32mm dia of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category.
Supply, fixing, testing and commissioning of 2 Core x 0.75sqmm control wiring ( Sheilded Wire) from outdoor to indoor units include PVC conduit with all necessary accessories to make it functional as per OEM Recommendation. Make: PolyCab, Havells, Finolex
Supply, Charging of Refrigerant Gas R410a as per OEM Recommendation (Make:- SRF Floron, Honeywell & Dupont)
Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units.
Supplying and installation for following size of perforated Hot Dipped Galvanised Iron Covered cable tray for exposed refrigerant pipe With Bends, Tee, Cross Member & Reducer (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
Supply and installation, testing, commissioning Outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specifed directed & Connisting of the following equipments:- (i) MCCB, 4 pole , 35 KA , 125 Amps adjustable to thermal Magnetic Release -01 No ( Incoming) (ii) MCCB,4 Pole,25 KA,32 Amps -02(Outgoing) (ii) MCCB, 4 Pole,25 KA,40 Amps - 01(Out going) (iii) MCCB, 4 Pole,25 KA,63 Amps-02(Outgoing) (iv) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set, Multifunction meter-01,Digital Ammeter-03 and auto phase sequencer MAKE : L & T/Secure/Conserv (v) Solid Copper bus 200 Amp for 3 phase and neutral , (vi) PCC and block Mesonry work for grouting of panel complete all as specified and directed, Note :The contractor shall get the drawings approved by the accepting officer before placing the orders.
Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick including testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)
Supply & fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drewn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required 32x6 mm galvanised iron strip including taking down old unserviceable one complete all as specified & as directed.
Supply, Laying, jointing and testing of electric cable XLPE 3.5 Core 95 sqmm insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.Make: Polycab, Universal , KEI , Finolex , Havells
M&L for control wiring with 4 core X 16 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed, Make : Finloex/Havells/Polycab (Note : Four run of wire with PVC conduit will be considered as one Length.)
M&L for control wiring with 4 core X 10 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 with on Cable Tray complete all as specified and directed, Make : Finloex/Havells/Polycab (Note : Four run of wire with PVC conduit will be considered as one Length.)
S&F Sheet metal enclosure factory made shutter type for double door 12 way distribution board (when MCBs are to be used) single pole and neutral, 240 Volts, with 100 Amp rated busbar, (MCBs are to be measured & paid separately) complete all as specified and directed.
S&F Sheet metal enclosure factory made shutter type for double door 16 way distribution board (when MCBs are to be used) single pole and neutral, 240 Volts, with 100 Amp rated busbar, (MCBs are to be measured & paid separately) complete all as specified and directed.
Supply and fixing MCB SP 6-32 Amps,10 KA,,'C' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB TPN 40-63 Amps,16 KA 'c' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable size of cable 2x1.5 sqmm (line conductor) & 1x1.5 sq mm (earth conductor). 1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & casing capping in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including mounting box for switch, socket complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable size of cable 2x2.5 sqmm (line conductor) & 1x2.5 sq mm (earth conductor). 1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & casing capping in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including mounting box for switch, socket complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
Supply and fixing MCB SPN 32 Amps,10 KA,,'C' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge.
Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed.
Dismantling of 3 x 15 TR central ac plant along with chiller , cooling tower ,expansion tank ,pumps, strainers piping, valves,AHU ,duct etc shifting them MES store yard wihin 6 km.
RefAir Technical Services (BID ID -3466040)
RUCHIKA ENGG.WORKS (BID ID -3462413)
Singh Associates (BID ID -3461273)
PANWAR ELECTRICALS (BID ID -3466752)
Shiv Enterprises (BID ID -3466971)
P S TRADERS (BID ID -3466956)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_823086.xls
BOQ • 0.26 MB
D50TENDER.pdf
Tender Documents • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .