Loading…
Loading…
Ref. No.
Tender Value
₹23.9 L
EMD Value
Exempted
Closing Date
1 Jun 2026, 5:00 pmClosed
UROLOGY CONSUMABLES
9152183
GEM/2026/B/7382267
Two Packet Bid
4 Fr Ureteric Catheter 70 cm,5 Fr Ureteric Catheter 70 cm,6 Fr Ureteric Catheter 70 cm,Smoke Evacua
South Delhi, Delhi
Group wise evaluation
BOQ
6 documents required · 6 mandatory
2 yrs
₹11 L
₹48 L
20%
DIRECTOR, Safdarjung Hospital, Department of Health and Family Welfare, Central Health Service Ministry of Health and, Family Welfare, Ministry of Health and Family Welfare, (Director)
Exempted
Yes
1 Jun 2026
11 May 2026
1 Jun 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | 4 Fr Ureteric Catheter 70 cm | Material Bio medically compliant Polyurethane PU polymer no pyrogenic and latex free Axial extension shall be approximate 70 cm plus minus 5 percent Open ended Distal configuration should consist of a meticulously formed atraumatic profile Should have full length intrinsic radiopacity must be integrated within the shaft matrix and circumferential graduation markings at standardized intervals and engineered torque stability to mitigate deformation or kinking during fluoroscopic or cystoscopy manipulation Secure Connector to allow leak free instillation of contrast via syringe to be provided to be supplied as sterile individually sealed units designated for single use clinical application only Secondary packaging must indicate the manufacturers name product details LOT number Mfg and Exp Dates and sterilization method The product must be ethylene oxide sterilized with visual confirmation to be provided Manufacturer shall possess a valid ISO 13485 2016 certification and the device must be CDSCO registered | 200 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 2 | 5 Fr Ureteric Catheter 70 cm | Material Bio medically compliant Polyurethane PU polymer no pyrogenic and latex free Axial extension shall be approximate 70 cm plus minus 5 percent Open ended Distal configuration should consist of a meticulously formed atraumatic profile Should have full length intrinsic radiopacity must be integrated within the shaft matrix and circumferential graduation markings at standardized intervals and engineered torque stability to mitigate deformation or kinking during fluoroscopic or cystoscopy manipulation Secure Connector to allow leak free instillation of contrast via syringe to be provided to be supplied as sterile individually sealed units designated for single use clinical application only Secondary packaging must indicate the manufacturers name product details LOT number Mfg and Exp Dates and sterilization method The product must be ethylene oxide sterilized with visual confirmation to be provided Manufacturer shall possess a valid ISO 13485 2016 certification and the device must be CDSCO registered | 1,300 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 3 | 6 Fr Ureteric Catheter 70 cm | Material Bio medically compliant Polyurethane PU polymer no pyrogenic and latex free Axial extension shall be approximate 70 cm plus minus 5 percent Open ended Distal configuration should consist of a meticulously formed atraumatic profile Should have full length intrinsic radiopacity must be integrated within the shaft matrix and circumferential graduation markings at standardized intervals and engineered torque stability to mitigate deformation or kinking during fluoroscopic or cystoscopy manipulation Secure Connector to allow leak free instillation of contrast via syringe to be provided to be supplied as sterile individually sealed units designated for single use clinical application only Secondary packaging must indicate the manufacturers name product details LOT number Mfg and Exp Dates and sterilization method The product must be ethylene oxide sterilized with visual confirmation to be provided Manufacturer shall possess a valid ISO 13485 2016 certification and the device must be CDSCO registered | 1,500 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 4 | Smoke Evacuator Filter | Should retain solid particles down to nano size at highest efficiencies remove bio hazardous contaminants retain aerosol droplets in liquid phase and retain volatile substances in the gas phase Should be able to retain inorganic particles bacteria viruses and cells efficiently Should possess a hydrophobic filtration medium retaining any contaminants in the liquid phase It should contain a medium for the retention of volatile chemicals Filtration efficiency Airborne particle removal efficiency less than 99 point 99 percent in accordance with EN1822 Airborne cellular bacterial removal efficiency 99 point 99 percent Airborne viral removal efficiency 99 point 99 percent Organic volatile reduction significant reduction of index substances Effective filtration area Approximately 50 sq cm connector ISO male luer connector with a rotating locking collar | 250 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 5 | Catheter valve | Ergonomically designed slide button to pass urine when no urine bag is attached valve should open automatically when urine bag to the valve is connected and should close once bag tube is removed should be suitable for use with both urethral and suprapubic catheters | 3,000 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 6 | 120 cm Veress needle | Needle should be sproing loaded blunt style mechanism should have sharp bevelled tip for quick and safe insertion outer diameter size 2 mm working length 120 mm bis certification | 100 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
| 7 | 150 cm Veress needle | Needle should be sproing loaded blunt style mechanism should have sharp bevelled tip for quick and safe insertion outer diameter size 2 mm working length 150 mm bis certification | 100 | pieces | Gajendra Singh 110029,OFFICE OF THE MEDICALSUPERINTENDENT SAFDARJUNG HOSPITALNEW DELHI-110029 | 180 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9152183.pdf
GEM_BID • 0.16 MB
boq_item_sample_file_-6_2026-03-23-11-04-25_a972c1e806a3666bcdc6b5475d9cbdf3.pdf
BOQ • 0.22 MB
boq_item_sample_file_-30_2026-03-23-11-04-26_274112ca8ae013433f3b743043371fbd.csv
BOQ • 0.00 MB
blacK_abb9a3c9-f713-40e7-aa7b1774245871410_SURGICALCONSUMABLE@SJH.pdf
GEM_OTHER • 0.46 MB
blacK_46e8001f-d4bc-41f4-9daa1774245935575_SURGICALCONSUMABLE@SJH.pdf
GEM_OTHER • 0.46 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .