| 1 | L1₹26.9 LAccepted-Finance | ₹26.9 L | L1 | Accepted-Finance BQR Conditions Satisfied |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-The above firm has not satisfied the BQR Condition No.1 i.e Relevant documents for the previous experience not uploaded. |
| Sl No | Description | Qty | Unit | SUSAND AGENCIES |
|---|---|---|---|---|
| 1.00 | Charges for dismantling the both side end covers by removing / cutting the bolt & nuts removing all copper tubes 19 mm OD length 3.048 mtr,Qty 600 Nos., cutting and removing the end tube sheet plates at both side OD 780mm dia thick 32mm materials MS and baffle sheets. | 1 | OPN | 38,800 ₹45,784 Lowest |
| 2.00 | Charges for cleaning of inner & outer surface of shell of chiller by sand blasting removing all erosions, grinding of welding portion, cleaning of grooves the fixing portions of baffle plates, painting the inner & outer surface of shell by anti corrosive paints, the rates including all consumables T & P hire charges etc., as per the direction of engineer in charge. | 1 | OPN | 30,000 ₹35,400 Lowest |
| 3.00 | Charges for fixing / welding of tube sheets end plates OD 900mm thick 38mm Qty 2 Nos material MS after providing tube fixing holes Qty of holes 1200 Nos. dia 19mm by drilling and grooving or reaming as per the direction of enginner in charge.(Retrieved MS Scrap of the Tube Sheet End Plate will be retained by the contractor) | 1,200 | NOS | 1,92,000 ₹2,26,560 Lowest |
| 4.00 | Charges for Fixing the end tube sheet plate (2Nos) at both sides OD 900mm thick 38mm qty 2 Nos. | 1 | OPN | 23,000 ₹27,140 Lowest |
| 4.10 | Contractors scope material MS plate (OD size=90cm, Thick 38mm) | 380 | KG | 28,500 ₹33,630 Lowest |
| 5.00 | Charges for Fixing the 23Nos baffle plate of size 730mm OD, thick 10mm materials polypropylene sheet at condenser, after providing at holes dia 20mm total no of holes 13800 as per the direction of engineer in charges. the rates including T&P hire charges, consumables etc., | 13,800 | OPN | 5,10,600 ₹6,02,508 Lowest |
| 6.00 | Charges for fixing the baffle plate at shell | 1 | OPN | 21,200 ₹25,016 Lowest |
| 6.10 | Contractors scope material Baffle sheet(k type arrangement) size 730 dia x 10 mm thick qty 23 nos, polypropylene sheet size(1250 x2000)mm | 6 | Nos | 21,000 ₹24,780 Lowest |
| 7.00 | Charges for provision of groove on the outer side of copper tubes (OD 19mm thick 1mm length 3048mm) for improving the heat transfer including the cost of materials, T & P and consumables. | 600 | Nos | 6,66,000 ₹7,85,880 Lowest |
| 7.10 | Contractors scope material :Copper tube Size [OD 19mm thick 1mm length 3048mm]No.Of Tube 600 | 894 | KG | 6,34,740 ₹7,48,993.2 Lowest |
Tender Value
₹25.8 L
EMD Value
₹19,300
Closing Date
10 Nov 2025, 2:00 pmClosed
CE/TTPS
CE/TTPS
TTPS Operation Circle MPMII ACP Reconditioning of released spare chiller unit from compressor B at unit IV and V AC plant
2025_EB_618066_1
CE/SE/O/TTPS/Spec.No.229/25-26
Open Tender
Miscellaneous Works
Item Rate
60 days
TTPS
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹19,300
Yes
24 Nov 2025
28 Oct 2025
11 Nov 2025
28 Oct 2025
10 Nov 2025
28 Oct 2025
Charges for dismantling the both side end covers by removing / cutting the bolt & nuts removing all copper tubes 19 mm OD length 3.048 mtr,Qty 600 Nos., cutting and removing the end tube sheet plates at both side OD 780mm dia thick 32mm materials MS and baffle sheets.
Charges for cleaning of inner & outer surface of shell of chiller by sand blasting removing all erosions, grinding of welding portion, cleaning of grooves the fixing portions of baffle plates, painting the inner & outer surface of shell by anti corrosive paints, the rates including all consumables T & P hire charges etc., as per the direction of engineer in charge.
Charges for fixing / welding of tube sheets end plates OD 900mm thick 38mm Qty 2 Nos material MS after providing tube fixing holes Qty of holes 1200 Nos. dia 19mm by drilling and grooving or reaming as per the direction of enginner in charge.(Retrieved MS Scrap of the Tube Sheet End Plate will be retained by the contractor)
Charges for Fixing the end tube sheet plate (2Nos) at both sides OD 900mm thick 38mm qty 2 Nos.
Contractors scope material MS plate (OD size=90cm, Thick 38mm)
Charges for Fixing the 23Nos baffle plate of size 730mm OD, thick 10mm materials polypropylene sheet at condenser, after providing at holes dia 20mm total no of holes 13800 as per the direction of engineer in charges. the rates including T&P hire charges, consumables etc.,
Charges for fixing the baffle plate at shell
Contractors scope material Baffle sheet(k type arrangement) size 730 dia x 10 mm thick qty 23 nos, polypropylene sheet size(1250 x2000)mm
Charges for provision of groove on the outer side of copper tubes (OD 19mm thick 1mm length 3048mm) for improving the heat transfer including the cost of materials, T & P and consumables.
Contractors scope material :Copper tube Size [OD 19mm thick 1mm length 3048mm]No.Of Tube 600
Charges for fixing of tubes 600nos OD 19mm thick 1mm in baffle and tube sheet end plates including baffle plates end plates reaming and testing of tubes as per the direction of Engineer in charge.(Retrieved Existing Copper Tube Scrap Will be retained by the contractor)
Labour charges for fixing the end covers at both sides of the chiller after providing suitable gaskets and fixing the HT bolt & nuts (size 24mm x 100mm) tightening the bolt & nut admitting water after inside of the shell and special testing for 7kg/cm2 and also admitting the N2 in the copper tubes total number of 600 at a pressure 300PST and kept out checked condition for about 48hours, after N2 gas and water should be released from the chiller as per the direction of engineer in charge.(The rates are including the consumbles like N2 gas,T &P hire charges and also pressure testing equipments etc.,)
Contractors scope material Nitrogen gas cylinder (7m³ each)
Contractors scope material HT bolt & nut (size: M24x100mm)
Charges for reconditioning of end cover (inlet/outlet port side)
Contractors scope material Gasket thickness 3mm
Transporting of condenser unit from TTPS to workshop (Outside of the TTPS) including & fro cost and insurance cost.
Less: Cost of retrieved Copper scrap (The copper scrapped to be retrieved by the contractor)
Less: Cost of retrieved MS scrap (The MS scrapped to be retrieved by the contractor)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_738672.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .