| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹30.1 L+₹2.5 L (9.08%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹31.6 L+₹3.9 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹34.8 L+₹7.1 L (25.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹34.8 L+₹7.2 L (25.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹28.8 L
EMD Value
₹57,500
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-08
SPL REPAIRS TO BLDG NO. E-78 (JCOs SINGLE LIVING) AT ARTY CENTRE UNDER GE GOLCONDA
2021_MES_496367_1
8542/E8
Open Tender
Civil Works
Item Rate
180 days
GE GOLCONDA
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCONDA
₹57,500
Yes
12 Apr 2022
21 Dec 2021
21 Jan 2022
21 Dec 2021
19 Jan 2022
5 Jan 2022
60 days
Amount
Dismantling Mangalore pattern roofing tiles or slate roofing complete all as specified and directed by Engr-in-Charge.
Dismantling battens for tiles, shingles etc of any size including tilting fillets n. exc 15 cm centre to centre complete all as specified and directed by Engr-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Dismantling of boarding, any description fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated mangalore profile sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S & F for Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240
S & F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Drilling holes round, drilled or cut in second class hardwood, diameter or side not exc 15 mm complete all as specified and directed.
S & F for mild steel screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm. but not exc 15cm complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed.
Taking down cement plaster on wall of any description including racking out joints for key scrubbing with water etc. complete all as specified and directed.
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC @ 3% over a coat of 10 mm thick ) on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. ( IWPC shall be measured and paid separately).
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces including 1.5 mm thick wall care putty on wall including preperation
M&L for preparing new plastered surfaces and applying Two coats of cement based paint on surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer on old surface of walls including 3mm thick wall care putty on wall complete all as specified and directed.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description in any position not otherwise specfically provided for as in sunken floors & floor etc complete all as specified and directed.
M & L for 25 mm thick PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) below tiles for levelling of existing surface complete all as specified and directed by Engineer - in- Charge.
Taking down shutters of any description not exceeding 1 Sq. M each complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but n.exc 2 Sqm each complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sq.M each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but n.exc 4 Sqm each (Without taking off shutters from the frames) complete all as specified and directed.
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glu,e pinned at joints complete all as specified and directed.
S & F 35 mm thick Second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for glazed/gauzed II class hardwood 30mm thick skelton shutters for windows open rebated and prepared to receive glass, gauze etc divided in to squares with sash bars plain chamfered or rounded, mitred and rebated sash bars complete all as pecified and as directed.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges.
S & F 125 mm long mild steel wire type I Gate and shutter, hook & eye.
S & F 100 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt.
S & F 125 mm size mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed by Engr-in-Charge.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with wooden beeds complete all as specified and directed.
M & L for hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads.
S & F for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty or wooden beading in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood gauzed and skeleton shutters for doors open rebated and prepared to receive glass, gauge etc., (without sash bars) edges of framing, plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters all as specified in SSR Part-I Section 8 clause 8.20 (a) complete all as specified and as directed.
Dismantling timber scantlings in fillets, rails, post , rafter, purlin etc under 40 Sqcm in section in any position unframed work complete all as specified and directed.
M&L for 2nd Class hardwood plain fillets, square or triangular in section, clean swan, secured with nails or brads croos sectional area exc 13 Sqcm but Not Exc 25 Sqcm complete all as specified and directed.
S&F 170mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S & F 125 mm long floor door stopper of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor all as specified and as directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges.
S & F 150 mm size mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed by Engr-in-Charge.
S & F 125 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt.
S & F for 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
M & L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed.
S & F in repairs 150 mm long floor door stopper of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor all as specified and as directed
S & F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with wooden beeds .
S & F in repairs 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards slabs/ blankets any thickness including cover fillets all as specified and as directed.
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed suface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 3mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear size aluminium foil and front side PVC lamination, complete all as specified and directed.
Supply only integral water proofing compound.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc.
S & F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 and fixed to PVC Doors complete
S&F 125 mm length of aluminium anodised barrel tower bolts of extruded section and fixed.
S&F 125 mm length of extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110mm dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed by Engr-in-Charge.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe flush pipe complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC connection 15mm dia, 45 Cms long with brass ferrules on both ends fixed complete
S & F in repair 15mm bore Bib taps, chromium plated cast copper alloy but fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm dia fancy type stop valves/ angle cock chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed;
S & F in repair 125mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union fixed complete all as specified and directed.
M&L for 15 mm bore GI Tubing medium grade with all fittings fixed to wall and ceiling in floor complete as specified including taking down existing u/s GI pipe line complete all as specified and directed by Engr-in-Charge.
M&L for 20 mm bore GI Tubing medium grade with all fittings fixed to wall and ceiling in floor complete as specified including taking down existing u/s GI pipe line complete all as specified and directed by Engr-in-Charge.
M&L for 25 mm bore GI Tubing medium grade with all fittings fixed to wall and ceiling in floor complete as specified including taking down existing u/s GI pipe line complete all as specified and directed by Engr-in-Charge.
S&F for rotational moulded polyethylene water storage tanks (multi-layar) (cylindrical vertical with closed top) of 2000 ltrs capacity hoisted and fixed in position all as specified including dismantling old tank complete all as specified and directed by Engr-in-Charge.
S&F in repair 25 mm Ball brass valves, high pressure, with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule and fixed in repair.
S&F in repair 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge..
S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge..
S & F PVC( SWR ) pipes 110mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down existing unserviceable pipe complete all as specified and directed.
S & F PVC( SWR ) pipes 75mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down existing unserviceable pipe complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore in repairs.
S&F PVC (SWR) bends with access door any radius 110mm bore in repairs.
S&F PVC (SWR) vent cowl 110mm bore.
S&F PVC (SWR) bends any radious 75 mm dia completee all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction single (single T) equal or unequal with access door, bore 75mm complete all as specified and directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish of the premises complete all as specified and directed by Engr-in-Charge.
M&L non skid coloured ceramic floor tiles 7-8 mm thick (square/ rectanglar ) area of each tile exc 0.06 sqm but n. exc 0.11 sqm laid over and including 15mm cement mortar screed in CM 1:6 set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L non skid coloured ceramic floor tiles 7-8 mm thick (square/ rectanglar ) area of each tile exc 0.11 sqm but n. exc 0.18 sqm laid over and including 15mm cement mortar screed in CM 1:6 set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L glazed ceramic coloured tiles in vertical surface 300X200X7mm thick laid over and including back coat 10mm thick in CM 1:4, set and and jointed in cement slurry and pointed with white or coloured cement to match. complete all as specified and directed by Engr-in-Charge.
M&L Rendering 5 mm thick in CM 1:3 on fair faces of brick surfaces of ceiling finished the surface fair and even complete all as specified and directed by Engr-in-Charge.
M&L for Praparation of newly plastered surfaces and applying Three coats of White wash on Ceiling complete all as specified and directed by Engr-in-Charge.
M&L for Praparation of old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed by Engr-in-Charge.
M&L for Preparing of old plastered wall surfaces and applying One coat of white wash complete all as specified and directed by Engr-in-Charge.
M&L for MS TMT bars, 10mm dia & over , cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire all as specified.
M&L for MS TMT bars,6 to 8mm dia cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire all as specified.
S&R in repair 110 mm CP Grating complete all as specified and directed by Engr-in-Charge.
S&F in repair for PVC waste pipe for urinal/WHB with all fitting etc 38 mm dia. 60mm long complete all as sprcified and directed.
S & F in repair vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) but exncluding waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor) beams, staircase, landing, chajjas and similar suspended work complete.
M&L for reinforced Cement Concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) nominal mix for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),etc for rough finished surfaces of flat concrete complete all as spd and directed.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,etc for rough finished surfaces of flat concrete complete all as spd and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in lintel bands, roof beams and cantilevers etc.
Use & waste of form work to sides and soffits of floor or roof beams, lintels, shelves including supports, overhungs etc. for flat rough finished surfaces completed all as specified and directed.
Taking down existing treatment along with plaster on vertical surfaces of sunken slabs complete all as specified and directed.
M&L 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) mixed with WPC surface finished even & smooth using extra cement as in sunken slabs (IWPC measured and paid seperately).
M&L for applying evenly a coat of industrial bitumen 85/25 at the rate of 1.2kg/Sqm including cleaning surface complete all as specified.
M&L rendering 15mm thick in CM 1:3 mixed with WPC on brick or concrete surfaces finished even and smooth without using extra cement (IWPC measured and paid separately) as in sunken slab.
S&F of low density polyethylene pipes (LDPE) of pressure rating 6 Kgf/sqcm fixed to walls, floors etc of 32mm bore as in spouts for sunken slabs
M&L PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in mass fillings.
S&F of steel ventilators with top hung shutter including hings, steel peg stay complete.
S&F in repairs wash down water closet (pedestal pattern) white complete with plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or high density or PVC 32mm dia for low level flushing cistern and connection complete all as pecified and directed.
S&F in repair vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP fancy type pillar tap, 01 Nos 32mm waste coupling , one pair of MS bracket, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S & F in repair tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges of brass chromium plated complete all as specified and directed.
S & F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement in repairs.
S&F PVC (SWR) junction double (double T) equal or unequal with access door, bore 110 mm.
S & F in repairs health faucet with spray jet (hand shower) cromium plated incl all fitting & fixtures complete all as specified
S & F in repairs brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete.
S&F in repair two way bib cock/ tap 15 mm chromium plated complete fancy type of branded as specified and directed.
M & L for PCC type D2 1:4:8 (using 40mm graded stone Aaggregate) as in foundations, filling and mass Concrete.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Taking down carefully existing point wiring of any description for (light, fan, sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets, fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc complete all as specified and directed.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring for one light point/ fan point/ bell point controlled by one switch complete with two runs of 1.5 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, copper conductor FRLS cable of 1100V grade conforming to IS - 694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked of suitable dia (not less than 20mm dia) with conduit accessories, surface type on wall/floor and fixed on ceiling/ roof/ truss/ columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti-corrosive paint for housing the switches, sockets, fan regulator etc and covered with 3 mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc., complete concealed in walls and provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc. making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per item no. 121 but One 3 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed by the Engr-in-charge.
All as per item no. 121 but One 3 pin 5/6 Amps switch socket outlet on same board complete all as specified and directed by the Engr-in-charge.
All as per item no. 121 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with two runs of 2.5 sqmm PVC (FRLS) insulated sheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated sheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed by the Engr-in-charge.
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed at site.
M&L switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and directed at site.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and directed at site.
M&L lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed at site.
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed at site.
M&L Fan Regulator (Rotary step type) 230/240V, AC complete all as specified and directed at site.
S&F 9 W LED bulb of base B22 with color temp 6500K all as specified and directed.
Supply and fixing LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
S & F Ceiling fan, with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete.
S&F Sheet metal enclosure MCB DB including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per item No- 135 above but TPN 4 way, 415 V complete all as specified and directed at site.
S&F MCB SPN, 240V, 10KA 'C' curve, 32 Amps.
S&F MCB SP, 240V, 10KA 'C' curve, 5 to 32 Amps.
S&F MCB TPN, 415V, 10KA 'C' curve, 40 to 100 Amps.
M&L Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.
All as per item No. 140 above but Sub main wiring using two runs of 4.0 sqmm wire with 4.0 sqmm earth wire complete all as specified and directed at site.
S&F in repair bracket suitable for fixing of security light fitting made out from 40 mm bore GI pipe, medium grade 2 metre in length (approx), made to shape as required, fixed to pole/wall with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required and all as specified and directed.
Taking down Ceiling fan, dismantling it and removing to store and refixing after assembling, in same position and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed.
M&L bands, straps, supports or stays for rain water, ventilating pipes including bolts if required hooks (stay) heavy for large gates, hook and pintle hinges, large hasps and staples, chains, hand made slidings bolts clamps hold fasts, wall ties hook for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts, bold, fixing and old one complete all as specified and directed at site.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation, PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber, provn of PCC cover 40 mm thick 1:2:4 mm type B1, funnel with water Pipe, GI pipe 15mm dia medium grade as protection pipe, GI earth lead complete all as specified and directed by the Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying of cables in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry river sand for cable cushioning including watering and consolidation in trenches complete all as all as specified and directed. Note:- Punned thickness shall be measured and paid.
M&L brick protection with common burnt old size bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
M & L for cutting of road/hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
M&L GI tubing , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed of size 40 mm bore.
Supplying, installing, commissioning and testing in repair factory made outdoor type LT Kiosk box made out of 3.15mm thick CRCA sheet duly powder coated with canopy, of size 1000mm x 600mm x 450mm with 4 nos 100 Amps aluminium busbar of length 75 cm including locking arrangement, embeded with 50x50x6mm mild steel angle iron frame and 600mm above the normal ground level complete PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) including taking down old unserviceable one complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less 1.5 mtrs below normal ground level connected to galvanised GI strip 32x6mm as earth lead by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation, PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber, provn of PCC cover 40 mm thick 1:2:4 mm type B1, funnel with water Pipe, GI pipe 15mm dia medium grade as protection pipe, GI earth lead complete all as specified and directed by the Engr-in-charge.
M/S Veerabhadra Constructions
m/s s indra reddy constructions
SAI RAM CONSTRUCTIONS
M/s D.Krishna Varma
sandhya enterprises
Neeru Constructions
Sri Lakshmi Enterprises
BUILDWEL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .