EXECUTIVE ENGINEER
Public Health Division, PWD, Puducherry
Augmentation of borewell sources for urban and peri urban areas of Puducherry Region. SW Supply, erection, testing and commissioning of HT LT Over Head Lines including distribution Transformer for extension of power supply to Swadeshi Cotton Mill
2019_PWDC2_5368_1
25/PHD/2019-20
Open Tender
Electrical Works
Item Rate
60 days
Puducherry
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
The Executive Engineer PHD PWD Puducherry
₹32,195
30 Jun 2025
6 Dec 2019
12 Dec 2019
6 Dec 2019
11 Dec 2019
6 Dec 2019
Amount
Supply and erection of 22 KV DP structure as per following specifications:- 30 feet RCC Pole 2 nos., 100 x 50mm channels, angles, Transformer bed channels, clamps bolts nuts and 22KV AB switch operating handle 1set, 22KV Pin insulator, HG fuses, 22KV LIghting arrestor, 0/2 SWG copper jumpering and alchanthin pipes, other supporting insulators and iron material and necessary civil works etc.
Supply of 30' RCC Pole.
Supply of H.T. stay set complete with rod, bow, 9" x 9" x 6mm thimble and guy shakle insulator.
Supply of L.T. Stay set complete with rod, bow, 9" x 9" x 6mm thimble and guy shakle insulator.
Supply of H.T tapping channel.
Supply of 11KV/22KV Disc insulator for 22KV over head line with 2 sets of 11KV disc insulator.
Supply of disc imetal parts of integral socketed type tension clamp complete with keeper piece, U bolt & nuts, spring washers with security clip.
Supply of G.I. wire (8SWG).
Erection of 30' RCC pole in cement concrete foundation 0.45 x 0.45x1.5 mts. and coping 0.45x0.45x1.5mts with ratio 1:3:6 using 20mm HBG metal including cost of concreting materials such as cement, jelly, sand etc., Excavation of pit and refilling. Supply of LT shacke insulator with metal paris.
Supply of V cross arm.
Sup0ply of H.T. guarding channel 75x45x10mm for 11/22 KV over head line.
Supply of F Clamp
Supply of MS bolt and nuts.
Supply of rail pole clamp, stay clamp RCC clamp, etc.
Erection of RCC stud pole including cost of concreting materials such as cement, jelly and sand etc., concrete ratio 1:3:6 using 20mm HBG metal including excavation if pit and refilling.
Fixing of F clamp in the poles for 11/22KV Over head line.
Fixing of H.T. tapping channel 100x50x50x10mm for 11/22KV Over head line including driling of holes for insulator and clamp.
Fixing of V cross arm in RCC/Rail/tubular pole for 11/22KV Over head line.
Fixing of H.T.guarding channel 75x45x10mm for 11/22 KV over head line.
Earthing line materials of the HT pole to the ground in the pole concrete including 8 SWG G.I. wires.
Erection of H.T. stay set complete in cement concrete ratio 1:3:6 (one cement:3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling as required.
Erection of L.T.stay set (without concrete)
Supply of three phase LT 4 feet cross arm.
Supply of 22KV pin insulator
Supply of 22KV GI pins.
Supply of LT shackle insulator with metal parts.
Supply of CI knobs.
Supply of ACSR conductor of 7/2.59 sqmm diameter.
Erection of ACSR conductor of 7/2.59 sqmm dia. Including winding extra as required.
Erection of three phase LT 4 feet cross arm.
Erection of LT pin insulator with GI pins.
Erection of LT shackle insulator with metal parts.
Erection of CI knobs.
Earthing with G.I. medium pipe 3.0 mt long and 40mm dia including accessories 250x50x6mm G.I. clamp with 12mm bolt, nut and washer for connecting earth wire, RCC ring enclosure and cover plate complete as required:-
Extra for salt and charcoat for pipe earth electrode as required:-
Supply and fixing of Copper flat 25x3mm.
Supplying and laying 8 SWG copper wire (4.0 mm dia.)
Dismantling of existing 30" RCC Pole with angles, cross arm insulators etc.,
Supply of HT stool.
Fixing of HT stool.
Supply and fixing of 150 mm dia G.I. pipe (medium class)
Supply of 3 1/2x 185Sqmm armoured aluminium U.G. cable - 1.1. KV grade. Mak: Finolex/Polycab.
Supply of 3 1/2x 300Sqmm armoured aluminium U.G. cable - 1.1. KV grade. Make: Finolex/Polycab.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of exceeding120 sq.m. but not exceeding 400 sq.m. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required in Mud Road.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonary open duct as required:-
Supplying and making end termination with coppy gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required: 3 1/2x185 sqmm.
Supplying and making end termination with coppy gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required: 3 1/2x300sqmm.
Supply and rection of 6Way 600Amps LT Feeder Pillar suitable for three phase 440V AC system. The pillar is made of finest quality steel sheet of 14SWG which is vermin proof and adequately ventilated. The bottom pedestal of the pillar provided with 50x50x6mm MS angle providing solid strength to the pillar box. Heavy duty hinges with steel insert for the smooth operation of door. Aluminimum double busbar of 50x10mm size to carry designed current inserted with heat shrinkable sleeves for safe operation. Two numbers of earthing terminal provided to facilitating better earthing of pillar box. Detachable type bottom glad plate with suitable gland of cable size. Porcelain base fuse holders with silver plated, copper contacts of suitable rating. Embossed name plate, lot no. and date of manufacturing.
Construction of Plinth for eretion of pillar Box. The cost should be inclusive of minor modification suitable for site condition as approved by the engineer-in-charge.
Supply and installation of 200KVA, 22000/433 volts outdoor Engergy Efficient transformer Level.II having specifications as under rating 200KVA voltage ratio, 22000/433 volts, Off load tap switch having 5 positions with voltage correction in steps of 2.5% suitable for mouting on the DP structure type of cooling ONAN, Winding : copper, standards and accessories as per relevant ISI standard with all accessories. Make: Wilson/Sakthi.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .