Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.5 L
EMD Value
₹11,500
Closing Date
25 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER, PERIYAKULAM MUNICIPALITY
Municipal Office Katcheri Road Thenkarai Periyakulam PIN 625 601 Phone 04546 234766
Providing extension of collection Main for Under Ground Drainage sewage pipe line in the extended areas in Idukkadi Lot street Ward No.16
2022_MAWS_265854_1
1453/2020/E1
Open Tender
Pipe Laying Works
Works
90 days
MUNICIPAL OFFICE, PERIYAKULAM
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹11,500
Yes
MUNICIPAL OFFICE, PERIYAKULAM
5 Dec 2022
19 Nov 2022
25 Nov 2022
19 Nov 2022
25 Nov 2022
19 Nov 2022
22 Nov 2022
Amount
Earthwork excavation and depositing on bankwith an initial lead of 10 m and initial liftof 2min Hard stiff clay, stiff black cotton, hard red earth, shales, murrams, gravel, stoney earh and earthmixed with small size boulders and hard gravelly soil etc., complete.and as directed by departmental officers
1 st depth 2m for collection main
2nd depth of 2 to 3 m
3rd depth of 3 to 4 m
Refilling with excavated earth complying with standard specifications for filling the foundations including watering & consolidation etc. complete as directed by Departmental officers etc., complete complying as per standard specification
Disposal of surplus excavated earth in pipe laying and road restoration works etc.,transporting to the sites specified by Engineer within 5 Km lead, including loading, spreading etc., complete and as directed by Departmental officers etc., complete complying as per standard specification
Supply of Structured-wall Plastics Piping Systems for non-pressure drainage and sewerage (Double Walled Corrugated pipes-DWC) of 200 mm dia with specification part 2 pipes and fittings with non-smooth external surface, type B as per IS-16098 (Part-2)-2013 including cost of elastomeric rubber O rings and including all taxes, duties, loading, unloading, freight, stacking and transit etc. complete at site etc.,and conveying of pipes to site and stacking properly along the alignment as per specifications.
Lowering DWC pipe of 200 mm dia of SN8 class of IS 16098 part-2 type B into the trenches and laying to proper grade and alignment as directed by Departmental officers etc., complete complying as per standard specification
Jointing of DWC pipe of 200 mm dia with elastomeric rubber O rings including cost of lubricants (including cost of jointing materials), testing the sewer line, including supplying and conveyance of water to site with a lead of 1km, labour etc. complete. as directed by Departmental officers etc., complete complying as per standard specification
Construction of Brick manhole of Depth 1.25 m and size of manhole 1.2 m x 0.9 m using Sulphate Resistant Cement at various depths including earthwork excavation as per SS in Hard stiff clay, stiff black cotton etc. , sand filling, laying cement concrete in 1:4:8 using 40mm B.G.jelly for levelling coarse, laying cement concrete in 1:2:4 using 20mm B.G.jelly for base slab, RCC M30 for roof slab, fabrication, placing reinforcement and timbering charges , brick work in C.M.1:3 using Bricks- II class Table Moulded (chamber burnt), for 23cm thick wall and over 23cm thick wall, plastering interior and exterior with C.M.1:3, 20 mm thick , providing PVC encapsulated steps, FRC MH frame and cover (heavy duty), benching and channelling with PCC 1:2:4, 20mm HBS, Shoring & strutting the sides of trench, refilling etc., complete for different depths for each manhole (As per the type design, drawing for manholes) complying with standard specifications for filling the foundations including watering & consolidation etc. complete as directed by Departmental officers etc., complete as per standard specification
Construction of Brick manhole of Depth 1.75 m and size of manhole of manhole 1.2 m x 0.9 m using Sulphate Resistant Cement at various depths including earthwork excavation as per SS in Hard stiff clay, stiff black cotton etc. , sand filling, laying cement concrete in 1:4:8 using 40mm B.G.jelly for levelling coarse, laying cement concrete in 1:2:4 using 20mm B.G.jelly for base slab, RCC M30 for roof slab, fabrication, placing reinforcement and timbering charges , brick work in C.M.1:3 using Bricks- II class Table Moulded (chamber burnt), for 23cm thick wall and over 23cm thick wall, plastering interior and exterior with C.M.1:3, 20 mm thick , providing PVC encapsulated steps, FRC MH frame and cover (heavy duty), benching and channelling with PCC 1:2:4, 20mm HBS, Shoring & strutting the sides of trench, refilling etc., complete for different depths for each manhole (As per the type design, drawing for manholes) complying with standard specifications for filling the foundations including watering & consolidation etc. complete as directed by Departmental officers etc., complete as per standard specification
Construction of RCC manholes 2.75 M depth and 1.50 M dia using Sulphate Resistant Cement at various depths including earthwork excavation as per SS in Hard stiff clay, stiff black cotton etc. , sand filling, laying cement concrete 1:4:8 using 40mm B.G.jelly for foundation, RCC M 30 for side wall and base slab, fabrication, placing reinforcement and shoring and strutting charges for depth upto and above 2.0m depth from G.L, providing PVC encapsulated steps, FRC MH frame and cover ( extra heavy duty) , benching and channelling with PCC 1:2:4, 20mm HBS,refilling etc., complete for the following sizes for each manhole (As per the approved design & drawing for manholes), and as directed byTWAD Board officers.
Construction of RCC manholes 3.75 M depth and 1.50 M dia using Sulphate Resistant Cement at various depths including earthwork excavation as per SS in Hard stiff clay, stiff black cotton etc. , sand filling, laying cement concrete in 1:4:8 using 40mm B.G.jelly for levelling coarse, laying cement concrete in 1:2:4 using 20mm B.G.jelly for base slab, RCC M30 for roof slab, fabrication, placing reinforcement and timbering charges , brick work in C.M.1:3 using Bricks- II class Table Moulded (chamber burnt), for 23cm thick wall and over 23cm thick wall, plastering interior and exterior with C.M.1:3, 20 mm thick , providing PVC encapsulated steps, FRC MH frame and cover (heavy duty), benching and channelling with PCC 1:2:4, 20mm HBS, Shoring & strutting the sides of trench, refilling etc., complete for different depths for each manhole (As per the type design, drawing for manholes) complying with standard specifications for filling the foundations including watering & consolidation etc. complete as directed by Departmental officers etc., complete as per standard specification
Barricading the trenches for one side using casuarina poles 8 to 10 cm dia , white PVC tape 15 mm wide with red strips printed in two rows, 75 mm dia red reflectors in every 3 m length, providing two no. of danger lights for every 150m length, including the cost of all materials, charges for fixing of barricading and removal of barricading after testing and filling the trench and stacking the post for reuse etc complete as directed by the Departmental officers etc., complete complying as per standard specification
Dewatering using the following diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete complying with standard specifications and as directed by Departmental officers etc., complete as per standard specification
Hire charges for Diesel Pump set For 3 HP
Hire charges for Diesel Pump set For 7.5 HP
Labour for cutting open BT Road surface for laying sewers (Vide separate estimate) etc complete as directed by the Departmental officers etc., complete complying as per standard specification
Road restoration with cement concrete 1:4:8, 10 cm thick, using 40 mm HBS metal and cement concrete 1: 11/2:3 , 10 cm thick using 20 mm HBS including cost of all materials laying, curing including earth work excavation for a depth of 40cm and sand filling for 10cm depth with filling sand etc complete as directed by the Departmental officers etc., complete complying as per standard specification
Sri Radha Constructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .