Loading…
Loading…
Tender Value
₹33.1 L
EMD Value
₹66,100
Closing Date
29 Jun 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GEN
12 conditions · 1 needing a document upload
For participating in tenders for an electrical nature of work, the contractor shall have to possess valid electrical license of appropriate voltage issued by any State Government under Clause 45 of Compilation of Rule of Indian Electricity Rules 1956 or as amended from time to time. Electrical works of 11KV and above including OHE, 'A' class Electrical Contractor license is essential. 2. The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the Electrical Contractor License along with the offer; otherwise the offer will be summarily rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
17 conditions · 1 needing a document upload
Tenderers are requested to submit their offers as per GST Tax regime. All the tenderers should ensure that they are GST compliant and their quoted tax structures/rates are as per GST law.
Conditions regarding inclusion of "Letter of credit" as mode of payment attached as "Annexure LC". As per Rly Bd Letter No. 2018/CE-I/CT/9 dt. 04.06.2018, special condition of LC has been applied. The contractor shall have the option to take payment from Railway through a letter of credit (LC) arrangement for all the tender having advertise cost of Rs. 10 Lakh or above
The above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter during execution of contract.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Latest GCC has been introduced and published / available on railway's website. The provisions of GCC will be applicable on all tenders published here after. Tenderers are requested to download the same from the railways website and ensure the implementation of the latest provisions made in GCC, while execution of work.
Contractor is to abide by the provisions of Payment of Wages act & Minimum Wages act in terms of clause 54 and 55 of Indian Railways General Condition of Contract ( copy uploaded and attached with this tender). In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. And upload requisite details of labour and their payment in this portal. These details shall be available in public domain. The Registration/ updation of Portal shall be done as par clause 55 C (i) of Indian Railways General Condition of Contract.
While processing payment of any 'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till ____ Month, _____Year."
Part(A):Banapura Balance Works of Station Building, Raising & Extension of PF No.2 & 3 BAY COP Work, parking area construction of boundary wall. Part(B):Bhopal Division: Provision of FOB at 5 Nos NSG 6 stations (PAL, CRK, PGL, DKI & DRA) in ET-KNW section. Part(C):BPL Div- Improvement of divyangjan facilities at SHRN, HD, NSZ, ET NDPM, SCI, BHS, BAQ, BINA, GUNA & SVPI stations
ELECT-GEN-BPL-T-15-2026
ELECT-GEN-BPL-T-15-2026
Open
Works - General
6 Months
Bhopal, Madhya Pradesh
₹0
₹66,100
29 Jun 2026
5 Jun 2026
15 Jun 2026
127 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 12,06,564.54 | ||
| — | 700.00 | — | — | ||
| Supply, erection, fixing, connecting, testing & commissioning of single core 10 sq.mm. multi-strand copper conductor conforming to IS:694:2010 or latest, 1100V grade for COP wiring as per specification attached. Make- HAVELLES, KEI, FINOLEX,POLYCAB or equivalent | — | — | — | 98,413 | |
| — | Breakup for | details. | — | ||
| "Supply includes the PVC cable duct size 50mmx50mm complete with case and cover to accommodate the cable.The MS clamps may be used of suitable size for holding the cable in duct where the cable is to be brought out for charging points. Make- POLYCAB, FINOLEX,PRESS FIT, PRECISION or equivalent" | — | — | — | 11,152.8 | |
| — | Breakup for | details. | — | ||
| Supply and fixing of Hot dipped galvanized perforated typed perforated cable trays of GI sheet of 300 mm width & 50 mm height along with suitable cover. The work includes the supply of perforated cable tray of GI having dimensions 300X1.6X50 mm along with GI sheet cover to fix on the cable tray of reputed make. The thickness of the cable tray should be of 1.6mm and 1.2mm for cable tray cover. The cable tray should be fixed upon the wall/pillar/gantries etc and similar other places with proper clamps,fixtures etc. as per the direction of Railway site Engineer. After laying of the cable of specified size properly in the cable tray as per the instruction of Railway site Engineer, the cable tray cover should be fixed with proper clamps, fixtures, nuts & bolts etc. The complete work shall be done to the full satisfaction of the Railways. Before erection of the cable tray the sample should be got approved by the Railways. | — | — | — | 97,341 | |
| — | Breakup for | details. | — | ||
| Supply, erection, connection, testing and commissioning of light points with MMS casing capping/ PVC pipe, or Switch socket , box as per site requirements . The wiring shall be carried out with 1.5 to 4 sqmm PVC insulated single core multistrand copper cable confirming to IS:694- 1990 or latest with one holder /ceiling rose on junction box with round plate with 2.5sq mm PVC insulated copper wire green color for earthing along with connection etc. asper wiring specification attached Make: For wire - HAVELLES,KEI, FINOLEX,POLYCAB or equivalent. For pipe- POLYCAB,FINOLEX,SHREENATH, PRESSFIT or equivalent. For switches -HAVELLES, L&T, Anchor, C&S,LEGRAND or equivalent. | — | — | — | 71,824.6 | |
| — | Breakup for | details. | — | ||
| Supply, installation, connecting, testing and commissioning of 12 ways double door single phase SDB comprising 1x32 A TPN C series MCB as incoming and 8x16 A SP C series MCBs as outgoing as per specification attached. Make -L&K, SIEMENS,HAGER, LEGRAND,SCHNEIDER or equivalent. | — | — | — | 16,924.04 | |
| — | Breakup for | details. | — | ||
| Supply, fixing, connection, testing & commissioning of ELCB/RCCB 25A DP RCCB 30mA breaking capacity as per specification attached. Make -L&K, SIEMENS,HAGER, LEGRAND,SCHNEIDER or equivalent. | — | — | — | 4,963.36 | |
| — | Breakup for | details. | — | ||
| Supply, erection, connection, testing and commissioning of VDB of 1x63A TPN MCB as incoming, 4x32A TP MCB as outgoing 0-200A ammeter with 100/5A C.T. & 3 way & OFF selector switch, 0-500V voltmeter with 3-way & OFF selector switch. 3 Nos. solid state 14/9 LED type line indicating lamps with fuses, 4 Nos. aluminium bus bars of suitable capacity as per specification attached. Make -L&K, SIEMENS,HAGER, LEGRAND,SCHNEIDER or equivalent. | — | — | — | 3,210.16 | |
| — | Breakup for | details. | — | ||
| Supply, installation, connecting, testing and commissioning of RCCB 64A TPN as per specification attached. Make -L&K, SIEMENS,HAGER, LEGRAND,SCHNEIDER or equivalent. | — | — | — | 3,584.19 | |
| — | Breakup for | details. | — | ||
| Supply, installation, connection, testing and commissioning of Out door type 40 watts LED weather proof fitting IP 65 or above with polycarbonate housing and diffuser 4 feet long (approx) suitable for surface mounting as well as suspended mounting under COP or as per site requirements complete with proper clamp fitting separate light/fan points, junction box and ceiling rose on truss as per specification attached. Make-PHILIPS, WIPRO,OSRAM, Jaquar, Havells or equivalent. | — | — | — | 1,20,937.5 | |
| — | Breakup for | details. | — | ||
| Supply, installation, connecting, testing and commissioning of 20 Watts INVERTER LED Batten tube complete with other accessories such as clamps, bracket, square block etc as per site requirements and specification attached. Make-PHILIPS, WIPRO, OSRAM, Jaquar, Havells or equivalent. | — | — | — | 19,995.5 | |
| — | Breakup for | details. | — | ||
| Supply, erection, fixing, connecting, testing & commissioning of 200 watts outdoor Led flood fitting complete in all respect and fixing by means of PVC conduit pipe complete with other accessories such as clamps, bracket, square block etc as per site requirements and specification attached. Make-PHILIPS, WIPRO,OSRAM, Jaquar, Havells or equivalent. | — | — | — | 64,882.38 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, fixing, connecting, testing and commissioning of 1400 mm sweep energy-efficient BLDC 5 star ceiling fan, complete with blades, mounted on ceiling, including making connections with 23/0.20 mm flexible copper wire from ceiling rose to fan, with Supply of fan regulator and down rod, complete in all respects. if required to be supply 1.5 feet long down rod as per specification attached. Make- BAJAJ,ORIENT, USHA, CROMPTON or equivalent." | — | — | — | 52,004.25 | |
| — | Breakup for | details. | — | ||
| Supply, erection, connecting, testing and commissioning of 2x18W fly catcher suitable for operation on 230 volts AC 3 mm thick MS flat clamps, nut bolts etc. on Railway platform under covered shed structure and connecting by means of PVC insulated flexible copper conductor to be drawn in 1/2" dia. flexible PVC conduit which shall be suitably supported from overhead conductors. | — | — | — | 35,466.3 | |
| — | Breakup for | details. | — | ||
| Supply, erection, fixing, connecting, testing & commissioning of metal body exhaust fan, 380 mm size sweep heavy duty 4 poles, single phase, 230V connected to earth and supply and connecting , fixing ofconnectors, fixtures etc. including civil works of opening in the wall and finishing the same. Make- BAJAJ,ORIENT, USHA, CROMPTON or equivalent. | — | — | — | 11,008.04 | |
| — | Breakup for | details. | — | ||
| Supply, fixing, connecting, testing and commissioning of digital timer switch 16A capacity, complete with associated accessories & enclosure. Make-L&T, SIEMENS,LEGRAND or equivalent | — | — | — | 9,841.12 | |
| — | Breakup for | details. | — | ||
| Supply, fixing, connecting, testing and commissioning of 3 pole power contactor type ML2 of L&T or equivalent, complete with associated accessories. Make-L&T, SIEMENS,LEGRAND or equivalent | — | — | — | 14,602.4 | |
| — | 5.00 | — | — | ||
| Dismantling of pole / OH line and transportation at suitable place as per site requirements. | — | — | — | 10,023.3 | |
| — | Breakup for | details. | — | ||
| Supply, installation, connecting, testing and commissioning of GI pipe earthing arrangement complete as per specification attached. | — | — | — | 40,045.5 | |
| — | Breakup for | details. | — | ||
| Supply, erection, connection, testing and commissioning of 8 SWG GI wire as per specification attached. | — | — | — | 2,189.1 | |
| — | Breakup for | details. | — | ||
| Laying, erection, connection and testing of PVC Aluminium armoured cable in the following manner and as per railways scope of work.(Note: Cable will be supplied by Railway at concerned depot.) | — | — | — | 56,576.2 | |
| — | Breakup for | details. | — | ||
| Supply of material and digging of trench in concrete area 30cms deep and 30 cms wide and laying of pipe or cable. The Contractor has to replaster the surface/floor with cement concrete etc. Pipe & Cable will be supplied as per relevant item of the schedule ( All other the material will be supplied by the contractor) | — | — | — | 38,671.5 | |
| — | Breakup for | details. | — | ||
| Supply and laying of heavy duty HDPE pipe of 160mm dia PN-6(Nominal Pressure), PE-100(Poly Ethylene grade ) or latest along with all required material for joining the pipes in the trench and other similar places. Make-Supreme, Miraj Pipes , Texmo , Astral or equivalent | — | — | — | 1,89,145 | |
| — | 250.00 | — | — | ||
| Laying, testing & Commissioning of cable in existing trench /DWC pipe/GI pipe/HDPE pipe as per specification attached. | — | — | — | 9,887.5 | |
| — | Breakup for | details. | — | ||
| Supply , fixing, testing & commissioning of 2.5 sq.mm single core multistrand copper conductor for main/submain wiring or circuit wiring as per specification attached. Make- HAVELLES, KEI, FINOLEX,POLYCAB or equivalent. | — | — | — | 3,684 | |
| — | 100.00 | — | — | ||
| Supply , fixing, testing & commissioning of 4 sq.mm single core multistrand copper conductor for main/submain wiring or circuit wiring as per specification attached. Make- HAVELLES, KEI, FINOLEX,POLYCAB or equivalent. | — | — | — | 5,619 | |
| — | 40.00 | — | — | ||
| "Supply, laying, fixing and testing of 32mm MMS PVC casing/capping for main/submain or other concealed wiring purpose as per specification attached. Make- POLYCAB, FINOLEX,PRESS FIT, PRECISION or equivalent" | — | — | — | 2,344 | |
| — | Breakup for | details. | — | ||
| "Supply installation, fixing, wiring ,connecting, testing, and commissioning of 70 watt out door type LED Street light fitting of PC IP66, High pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management rating complete with wiring suitable MS clamps, nut - bolts, anchor fasteners, bend pipe etc as per site requirement Make-PHILIPS, WIPRO,OSRAM, Jaquar, Havells or equivalent. " | — | — | — | 39,292 | |
| — | Breakup for | details. | — | ||
| Supply of material and erection of Octagonal galvanized steel pole of 5 mtr height on cement concrete foundation complete with foundation bolts, single arm etc. as as per railway specification attached. Make- BAJAJ, PHILIPS, CROMPTON or equivalent | — | — | — | 1,72,936.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCCorrectionslip.pdf
ATTACHMENT
RB200824GOI190724.pdf
ATTACHMENT
TechnicalSpecification_1.pdf
ATTACHMENT
GCC 2022
ATTACHMENT
AnnexureVIB_1.pdf
ATTACHMENT
AnnexureLC_1.pdf
ATTACHMENT
WCRLEDSpecificationsforLEDlights_1.pdf WCR LED Specifications
ATTACHMENT
SpecialCondition_1.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22_1.pdf
ATTACHMENT
WCRLEDSpecificationsforLEDlights_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .