Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹63,800Qualified Make: microtek
Model: MICROTEK UPS TP PRO 650+ 003 REDDY APARTMENT 04 1 HORAMAHU MAIN ROAD BANGALORE BANGALORE KARNATAKA 560043 | BENGALURU URBAN | KARNATAKA | 560043 | Make: microtek
Model: MICROTEK UPS TP PRO 650+ | L1 | Qualified | |
| 2 | L2₹1.1 L+₹50,750 (79.5%)Qualified Make: microtek
Model: Microtek UPS 1000VA Twin Guard 70 3 BLOCK A DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110042 INDIA | NORTH DELHI | DELHI | 110042 | Make: microtek
Model: Microtek UPS 1000VA Twin Guard | L2 | Qualified | |
| 3 | L4₹1.2 L+₹55,100 (86.4%)Qualified Make: microtek
Model: UPS TGE PRO 100+ C 305 MANUBHAI TOWER OPP COMMERCE COLLEGE SAYAJIGUNJ VADODARA GUJARAT 390005 UDYAM GJ 24 0040300 24AARFS2191R1ZC R M | VADODARA | GUJARAT | 390005 | Make: microtek
Model: UPS TGE PRO 100+ | L4 | Qualified | |
| 4 | L5₹1.2 L+₹55,390 (86.8%)Qualified Make: microtek
Model: MICROTEK 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | Make: microtek
Model: MICROTEK | L5 | Qualified | |
| 5 | L6₹1.2 L+₹57,710 (90.5%)Qualified Make: microtek
Model: Microtek Twin Guard Pro + 3 1106 JANKI PURAM EXTN SITAPU ROAD JANKI PURAM LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Make: microtek
Model: Microtek Twin Guard Pro + | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
14 Sept 2018, 2:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 29 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 * Technology IGBT-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC
50 Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP 20 IP-21
IP 20 Inverter Efficiency (%) >/= 60% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 2 Years 1 Year
2 Years
5 Years
3 Years 1/4 Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes
No Inverter out put socket AC out put for printer (not through inverter) 2 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 2/4 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Debkinandan Joshi 110010
CE (WAC) AF PALAM DELHI CANTT 29 15
568562
GEM/2018/B/80657
Line Intractive UPS with AVR
15 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 29 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 * Technology IGBT-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP 20 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 60% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years 1/4 Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) 2 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 2/4 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Debkinandan Joshi 110010 | - | - | - |
| CE (WAC) AF PALAM DELHI CANTT 29 15 | - | - | - |
Exempted
14 Sept 2018
7 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_568562.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .