| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Bidder is L1 | |
| 2 | L2₹48.5 L+₹1.9 L (4.03%)Rejected-AOC | L2 | Rejected-AOC Bidder is L2 | |
| 3 | L3₹48.9 L+₹2.2 L (4.75%)Rejected-AOC | L3 | Rejected-AOC Bidder is L3 | |
| 4 | L4₹52.3 L+₹5.7 L (12.1%)Rejected-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L4 | Rejected-AOC Bidder is L4 | |
| 5 | L5₹57.7 L+₹11.0 L (23.6%)Rejected-AOC 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L5 | Rejected-AOC Bidder is L5 |
| Sl No | Description | Qty | Unit | CHOUDHARY AND SONS L5 | KULBHUSHAN AGGARWAL L8 | JAI DURGA CONSTRUCTION CO L3 | kailu construction co L1 | R D Bansal L7 | BHARAT ENGINEERS L2 | M/s Trade Linker Associates L6 | Roy and Sons Infrastructures L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commisioning compact sub-station complete with 500 KVA transformer step down, standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with , OCTC tappings on HT side to vary secondary voltage within limit, all as per IS:1180 , level 3. RMU 11 KV, 630 Amp, having SF6 VCB, LT side 1000 A FP ACB , 50 KA, Out going MCCBs
Note (i) Make of Compact sub station, ACB, RMU, Transformer, LT Panel, CT etc shall be from Group-I as mentioned in Appx 'B'
(ii) Cost of foundation testing commisionming etc included in rates. | 1 | Each Job | 44,00,786 ₹44,00,786 | 52,88,000 ₹52,88,000 | 39,00,000 ₹39,00,000 | 35,78,000 ₹35,78,000 Lowest | 48,10,000 ₹48,10,000 | 36,83,786 ₹36,83,786 | 45,68,000 ₹45,68,000 | 39,00,000 ₹39,00,000 |
| 1.10RMU-NON-Extensible 1 way, 11KV, 1 SF6 circuit breaker along with connected accessories etc. Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 01 No. Direct Cable Module & 01 no. 630A Fixed Manual SF6 Circuit breaker- a. Self Powered Relay, Type IDMT b. Ring Switches and T OFF SF6 circuit breaker with integrated Earthing Switches c. Live Cable Indicator for Ring Switches d. Padlocking facility e. Shunt trip coil rating – 230V AC f. Padlocking facility. Current Transformer –Cast resin Ratio: 50-25/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA Protection:- Numerical 2OC + 1EF Relay Indication Lamps :-VCB off / on / auto trip/ Trip circuit healthy/spring charge indication Metering :- Digital meter | |||||||||||
| 1.20Transformer :- - 500 KVA, 11/0.433 KV, Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box as per IS-1180(Part-1):2014 Level -3 and as per IS-1180(Part-1):2014 EEL- 3 with amendment no.- 1,2,3 & 4. Losses should not be more than following :- Losses @50% Load - 1354 W, Losses @100% Load - 3909 W | |||||||||||
| 1.30LT Panel :- Incomer – 01 No. - 1000 Amp, 4 Pole, 415V, 50KA, MDO Air Circuit Breaker microprocessor based with O/L, S/C & E/F Protection. - RYB Indication Lamp - Ammeter - Voltmeter Outgoing – (a) 02 Nos. - 400 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection. (b) 02 Nos. - 200 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection. (c) 01 No. - 125 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection | |||||||||||
| 1.40CT :- 1000A/5A, LTCT Cl:1.0 Space Heater with ON/OFF Switch and Thermostat Socket Point Single phase switch with socket, Lamp LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control Outdoor installation : MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel. Cable arrangment :Provision for receiving Incoming cables thro Bottom entry and out going through Bus bar to Trf panel, including Termination Kit & Glands HT Cable arrangment :Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry & Glands Bus Bar – Aluminum Earth Bus – Aluminum Paint shade: Siemens Grey ( RAL 7032) or as approved by Garrision engineer Foundation :- All as per OEM design/recommendation ( Cost of foundation included in quoted rates) Note for item 1 :- Pre-despatch inspection for compact sub stn, RMU shall be carried out by representative of AO and necessary cost of testing charges in manufacturing testing lab and other installation at site shall be borne by the contractor. | |||||||||||
| 2.00 | Supply, laying & testing cable of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 240 sqmm 3 core, complete, all as specified & directed. | 60 | RM | 1,850 ₹1,11,000 | 2,000 ₹1,20,000 | 2,100 ₹1,26,000 | 1,900 ₹1,14,000 | 1,750 ₹1,05,000 Lowest | 1,900 ₹1,14,000 | 2,100 ₹1,26,000 | 1,800 ₹1,08,000 |
| 3.00 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm, complete, all as specified & directed. | 2 | Each | 6,500 ₹13,000 | 4,000 ₹8,000 | 4,000 ₹8,000 | 6,500 ₹13,000 | 3,550 ₹7,100 | 3,500 ₹7,000 Lowest | 9,000 ₹18,000 | 14,500 ₹29,000 |
| 4.00 | Supply, fabricating, installation, testing & commissioning of LT panel, outdoor type, CPRI approved, double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply, factory made, fully compart mentalized made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclosure IP 54 as per IS 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, including the following :-
(a) Aluminium bus bar of capacity 800 Amps for Three phase and Neutral. -04 No's
(b) Combined Voltmeter & Ammeter 0 to 500 Amps, digital type with built in selector switch CTS of suitable ratio (Set of Three)
(c) Indication lamp RYB-01 Set
Incoming : (i) MCCB, 4P, 400 Amps, 36 KA, 415 Volts, Microprocessor, Adjustable Overload, Short-circuit, Ground fault :-01 Nos
(ii) On load Change Over Switch 400 Amp 4 Pole -01 Nos
Outgoing :
(i) MCCB, FP, 200 Amps, 36 KA, 415 Volts , Microprocessor, Adjustable Overload, Short-circuit, Ground fault-04 Nos
(ii) MCCB, FP ,125 Amps, 10 KA, 415 Volts , Adjustable thermal magnatic release.-01 Nos | 2 | Each | 2,65,000 ₹5,30,000 | 1,70,000 ₹3,40,000 Lowest | 1,95,000 ₹3,90,000 | 1,85,000 ₹3,70,000 | 2,19,000 ₹4,38,000 | 2,52,949 ₹5,05,898 | 2,40,000 ₹4,80,000 | 2,00,000 ₹4,00,000 |
| 5.00 | M & L for taking out exsting cable from existing panel/ main switch / change over etc and connecting it to new LT panel including new thimbles/ lugs, nut bolt etc complete, for cable size 70 Sqmm to 150 sqmm | 8 | Each Job | 1,500 ₹12,000 | 500 ₹4,000 | 150 ₹1,200 Lowest | 1,500 ₹12,000 | 450 ₹3,600 | 500 ₹4,000 | 1,500 ₹12,000 | 2,000 ₹16,000 |
| 6.00 | Supply, Laying, jointing and testing of XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty ) with stranded aluminium conductor, cross sectional area 400 Sqmm 3.5 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified & directed.
Note Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items. | 100 | RM | 2,300 ₹2,30,000 | 2,188 ₹2,18,800 | 1,900 ₹1,90,000 | 2,070 ₹2,07,000 | 1,840 ₹1,84,000 Lowest | 1,940 ₹1,94,000 | 2,300 ₹2,30,000 | 2,102 ₹2,10,200 |
Tender Value
₹63.5 L
EMD Value
₹1.2 L
Closing Date
22 Jul 2025, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Jalandhar Cantt PIN 144005
Provn of 500 KVA transformer in existing sub station at Sainik school Kapurthala
2025_MES_708622_1
8325/15/E8
Open Tender
Civil Works
Item Rate
180 days
HQ CWE Jalandhar Cantt
Class C Category b(ii) for contractors enlisted with MES
9 documents required · 9 mandatory
₹1,000
Yes
GE Kapurthala
₹1.2 L
Yes
19 Sept 2025
24 Jun 2025
25 Jul 2025
24 Jun 2025
22 Jul 2025
16 Jul 2025
Amount
Supply, installation, testing & commisioning compact sub-station complete with 500 KVA transformer step down, standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with , OCTC tappings on HT side to vary secondary voltage within limit, all as per IS:1180 , level 3. RMU 11 KV, 630 Amp, having SF6 VCB, LT side 1000 A FP ACB , 50 KA, Out going MCCBs Note (i) Make of Compact sub station, ACB, RMU, Transformer, LT Panel, CT etc shall be from Group-I as mentioned in Appx 'B' (ii) Cost of foundation testing commisionming etc included in rates.
RMU-NON-Extensible 1 way, 11KV, 1 SF6 circuit breaker along with connected accessories etc. Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 01 No. Direct Cable Module & 01 no. 630A Fixed Manual SF6 Circuit breaker- a. Self Powered Relay, Type IDMT b. Ring Switches and T OFF SF6 circuit breaker with integrated Earthing Switches c. Live Cable Indicator for Ring Switches d. Padlocking facility e. Shunt trip coil rating – 230V AC f. Padlocking facility. Current Transformer –Cast resin Ratio: 50-25/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA Protection:- Numerical 2OC + 1EF Relay Indication Lamps :-VCB off / on / auto trip/ Trip circuit healthy/spring charge indication Metering :- Digital meter
Transformer :- - 500 KVA, 11/0.433 KV, Copper Wound Step Down “BIS Marked” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box as per IS-1180(Part-1):2014 Level -3 and as per IS-1180(Part-1):2014 EEL- 3 with amendment no.- 1,2,3 & 4. Losses should not be more than following :- Losses @50% Load - 1354 W, Losses @100% Load - 3909 W
LT Panel :- Incomer – 01 No. - 1000 Amp, 4 Pole, 415V, 50KA, MDO Air Circuit Breaker microprocessor based with O/L, S/C & E/F Protection. - RYB Indication Lamp - Ammeter - Voltmeter Outgoing – (a) 02 Nos. - 400 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection. (b) 02 Nos. - 200 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection. (c) 01 No. - 125 Amp, 3 Pole, 415V, 36KA, Manual Fixed Type MCCB with thermal magnetic based release with O/L & S/C protection
CT :- 1000A/5A, LTCT Cl:1.0 Space Heater with ON/OFF Switch and Thermostat Socket Point Single phase switch with socket, Lamp LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control Outdoor installation : MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel. Cable arrangment :Provision for receiving Incoming cables thro Bottom entry and out going through Bus bar to Trf panel, including Termination Kit & Glands HT Cable arrangment :Provision for receiving Incoming through bus duct by bus bar and Outgoing thro cable box bottom entry & Glands Bus Bar – Aluminum Earth Bus – Aluminum Paint shade: Siemens Grey ( RAL 7032) or as approved by Garrision engineer Foundation :- All as per OEM design/recommendation ( Cost of foundation included in quoted rates) Note for item 1 :- Pre-despatch inspection for compact sub stn, RMU shall be carried out by representative of AO and necessary cost of testing charges in manufacturing testing lab and other installation at site shall be borne by the contractor.
Supply, laying & testing cable of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 240 sqmm 3 core, complete, all as specified & directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm, complete, all as specified & directed.
M & L for taking out exsting cable from existing panel/ main switch / change over etc and connecting it to new LT panel including new thimbles/ lugs, nut bolt etc complete, for cable size 70 Sqmm to 150 sqmm
Supply, Laying, jointing and testing of XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty ) with stranded aluminium conductor, cross sectional area 400 Sqmm 3.5 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified & directed. Note Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including taking out old & removal, complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, electrode connection using copper of size 20mmx3mm thick by means of bolts, nuts, check nuts and washers of galvanized iron connected to main switch board and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:2:4) type B-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip, complete, all as specified & directed.
M&L for cement concrete (1:2:4), type B-2 using 40mm graded crushed stone aggregate as Cement concrete in foundations, filling and mass concrete, complete, all as specified and directed.
S&F mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290. Gde E-165 complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type all as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, omplete all as specified and directed.
M&L for steel Round bars Fe-410 -W (Gde E-250) 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
S&F MS screw bolts (machine made) with hexagonal or square head at one end, screwed end to be fitted with washer and one hexagonal/square nuts exc 10 cm and not exc 15mm , dia of neck 5 to 10mm, complete, all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width of girth not otherwise described and applying two coats of synthetic enamel paint over a coat of Zinc chrome primer, complete, all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified & directed.
BHARAT ENGINEERS (BID ID -3367601)
JAI DURGA CONSTRUCTION CO (BID ID -3367099)
Roy and Sons Infrastructures (BID ID -3367676)
CHOUDHARY AND SONS (BID ID -3366429)
M/s Trade Linker Associates (BID ID -3367656)
R D Bansal (BID ID -3367507)
KULBHUSHAN AGGARWAL (BID ID -3366758)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .