| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | ₹9.1 L Quoted ₹9.3 L | L1 | Accepted-AOC Lowest quoted hence admitted |
| 2 | L2₹10.1 L+₹86,470 (9.32%)Rejected-AOC | ₹10.1 L+₹86,470 (9.32%) | L2 | Rejected-AOC Not lowest hence not admitted |
| 3 | L3₹10.4 L+₹1.2 L (12.5%)Rejected-AOC | ₹10.4 L+₹1.2 L (12.5%) | L3 | Rejected-AOC Not lowest hence not admitted |
| 4 | L4₹15.9 L+₹6.7 L (71.7%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | ₹15.9 L+₹6.7 L (71.7%) | L4 | Rejected-AOC Not lowest hence not admitted |
Tender Value
Refer Docs
EMD Value
₹20,600
Closing Date
26 Apr 2022, 6:00 pmClosed
SHRI VINEET MODI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
COMPREHENSIVE MAINT TO AIR COOLED DUCTABLE AC AND WALK IN COOLERS/ COLD STORAGES INCL REPLACEMENT OF SPARES AT CHAF BANGALORE
2022_MES_514837_1
87447CWEAFNBAN
Open Tender
Civil Works
Item Rate
360 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹20,600
Yes
24 Jun 2022
23 Mar 2022
28 Apr 2022
23 Mar 2022
26 Apr 2022
14 Apr 2022
24 Mar 2022 - 2 Apr 2022
Amount
Comprehensive maintanance to ductable split type AC 11 TR capacity of any make including servicing of cooling coil, expansion valve ,01XOutdoor and 01Xindoor unit as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- ICCU)
Comprehensive maintanance to ductable split type AC 8.5 TR capacity of any make including servicing of 01X Air handling unit with belt driven motor ,blower's air filters,shaft assembly,cooling coil,expansion valve ,02XOutdoor and 01Xindoor units as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure and oil level of compressor, charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- CTVS OT)
Comprehensive maintanance to ductable split type AC 5.5 TR capacity of any make including servicing of cooling coil, expansion valve ,01XOutdoor and 01Xindoor units as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- CTVS corridor) .
Comprehensive maintanance to ductable split type AC 7.5 TR capacity of any make including servicing of cooling coil, expansion valve ,02XOutdoor and 01Xindoor units as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- Nuclear medicine-1) .
Comprehensive maintanance to ductable split type AC 7.5 TR capacity of any make including servicing of cooling coil, expansion valve ,02XOutdoor and 01Xindoor units as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- Nuclear medicine-2) .
Comprehensive maintanance to ductable split type AC 5 TR capacity of any make including servicing of cooling coil, expansion valve ,01XOutdoor and 01Xindoor units as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- Nuclear medicine-2) .
Comprehensive maintanance to Air handling unit with 5.5 TR capacity Outdoor and indoor Unit (Make-BLUE STAR)-02 Nos including servicing of AHU's belt driven motor ,blower's air filters ,shaft assembly,cooling coil,expansion valve , as and when ordered as in preventive maintenance including cleaning,removing the dust particles of air filters replacement of all worn out parts greasing of fan motors, checking of gas pressure,charging of refrigerant etc all as required for the smooth and satisfactorily functioning all as directed by engineer-in-charge.(Location- ART Familywing) Note for Item No 1 to 7: (i)Replacement of spares/parts shall be measured and paid separately under relevant items of this Schedule.(ii) Contractor will responsible for maintaining a Record / Register of servicing/Repairing.
Supply only Compressor suitable for ductable type split type AC of capacity 11TR in replacement , complete all as specified and directed. Location: ICCU. Make of compressor KIRLOSKAR / TECUM SEH / SHRI RAM /COPELAND/ DANFOSS Notes :- (a) Old compressor taken down/ removed shall be replaced with the same make.(b) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer as one to one replacement. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. Supporting documents for replacement from manufacturer/ dealer alongwith warranty certificate and paid vouchers shall be furnished by the Contractor before claiming payment.
All as per Sl item No.8.00 here in before but for 8.5 TR AC Location :CTVS OT Make of compressor: KIRLOSKAR / TECUM SEH / SHRI RAM /COPELAND/ DANFOSS
All as per Sl item No.8.00 here in before but for 7.5 TR split type AC .Location :Nuclear medicine-1,2. make of compressor: KIRLOSKAR / TECUM SEH / SHRI RAM /COPELAND/ DANFOSS
All as per Sl item No.8.00 here in before but for 5/5.5 TR split type AC . Location :CTVS,Nuclear medicine. Make of compressor: KIRLOSKAR / TECUM SEH / SHRI RAM /COPELAND/ DANFOSS
M&L for Pressure testing and rectifying the leakages found in the system of ductable type split ACs /5.5/7.5/8.5/11 Ton capacity including vacuuming and charging the refrigerant (R 22) gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.
Supply only remote sensing unit/assembly suitable for 11 Ton ductable split type AC corded/ cordless with PCB board in replacement, complete all as specified and directed.
Supply only remote sensing unit/assembly suitable for 8.5Ton ductuble split type AC corded/ cordless with PCB boardin replacement, all as specified and as directed.
Supply only remote sensing unit/assembly suitable for 7.5Ton ductuble split type AC corded/ cordless with PCB board in replacement , all as specified and as directed.
Supply only remote sensing unit/assembly of ductable type split Acs,5/5.5 TR corded/ cordless, with PCB board in replacement all as specified and as directed.
Supply only contactor assembly suitable for ductable type split Acs of 5/5.5/7.5/8.5/11 TR capacity upto 32Amps for AC replacement , all as specified and as directed.Make L&T equivalent in Schneider/Siemens
Supply only compressor oil suitable for 5.5/7.5/8.5/11 TR ductable split AC ,complete all as specified and directed.
Supply only refrigerant (R-22) for 5.5/7.5/8.5/11/TR ductable split AC & walk in cooler complete all as directed by Engineer- in- charge.
Supply only refrigerant (R-407) for 11 TR ductable split AC complete all as directed by Engineer- in- charge.
Supply only Heat insulation superior quality nitrile rubber for copper tubing any size of refrigerant line including necessary clamps pvc tape knots etc complete all as specifiedMake; Superlon
Supply only running capacitor 8mfd suitable for fan/blower motor upto 5-7.5 TR dutcable ACs as in replacement , complete all as specified Make EPCOS/Keltron
Supply only running capacitor 10 mfd suitable for fan/blower motor upto 8.5-11 TR dutcable ACs as in replacement ,complete all as specified Make EPCOS/Keltron
Supply only fan blade, suitable for 5.5/7.5 Ton capacity ductable type AC blower motor of any make, as in replacement all as specified and as directed.
Supply only fan blade, suitable for 8.5/11 Ton capacity ductable type AC blower motor of any make,as in replacement all as specified and as directed.
Supply only electric blower motor 230v for indoor , ductable type AC any type of capacity5/5.5 TR as in replacement ,compete all as specified and directed.
Supply only electric blower motor 230v for indoor , ductable type AC any type of capacity 8.5/7.5 TR as in replacement,compete all as specified and directed.
Supply only electric blower motor 230v for indoor , ductable type AC any type of capacity 11 TR as in replacement, compete all as specified and directed.
Supply only electric condensor fan motor 230v for outdoor, ductable type AC any type of capacity 5/5.5 TR as in replacement,compete all as specified and directed.
Supply only electric condensor fan motor 230v for outdoor ductable type AC any type of capacity 8.5/7.5TR as in replacement ,compete all as specified and directed.
Supply only electric condensor fan motor 230v for outdoor ductable type AC any type of capacity 11 TR in replacement ,compete all as specified and directed.
Supply only expansion valve for ductable type AC any type of capacity 5/5.5 TR in replacement,compete all as specified and directed.Make Danfoss
Supply only expansion valve for ductable type AC any type of capacity 7.5 TR in replacement ,compete all as specified and directed.Make Danfoss
Supply only expansion valve for ductable type AC any type of capacity 8.5 TR in replacement, compete all as specified and directed.Make Danfoss
Supply only expansion valve for ductable type AC any type of capacity 11 TR in replacement,compete all as specified and directed.Make Danfoss
Supply only expansion valve suitable for walk in cooler 3 TR capacity in replacement, complete all as specified and directed.Make Danfoss
Supply only copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs in replacement, all as specified and as directed
Supply only Copper tube, 9 mm dia, superior quality suitable for refrigeration and discharge lines of split ACs in replacement all as specified and as directed.
M & L for detecting faults at site of ductable type split Acs of 5.5/7.5/8.5/11 TR any type and make under AGE EM CHAF and rectifiying the defects and make functional including replacing of unserviceable defective electrical/spares accessories Note :- (i) Rate for any item shall be measured and paid under respective item of schedule . (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the detect fault shall be deemed to be included in the quoted rate. (iii) The work is of day to day maintenace, required Ref& Mech and Helper has to be attend daily for carryout the above work.
Comprehensive maintanance to unmanned walk in cooler 3 TR /cold storage 3TR with air cooled condenser, working 24 hours of CHAFB including cleaning, checking of cooling coil, condenser and electric motor and cleaning of compressor and condenser externally with vacuum cleaner replacement of starting and running capacitor, rubber wheels relays, replacing of condensing fan motor and all electrical parts and electrical wiring etc. as and when required, tightening of electrical connections, greasing of electric motor, checking of gas pressure toppingup gas to the desired pressured level to ensure serviceability through out the maintenance period to the entire satisfaction of Engineer-in-charge.Location :Med store-03 Nos,Path lab-02 No,ECHS-01.Total-6x3 job. Note: (i)Replacement of spares/parts shall be measured and paid separately under relevant items of this Schedule.(ii) Contractor will responsible for maintaining a Record/Register of servicing/Repairing.
Pressure testing and rectifying the leakages found in the system of walk in cooler 3 Ton/cold storage 3 Ton capacity including vacuuming and charging the refrigerant (R 22) gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.
Supply only compressor suitable for 3 Ton walk in cooler/ 3 Ton cold storage in replacement all as specified and as directed. Location:Med store,Path Lab,ECHS store Make of compressor: KIRLOSKAR / TECUM SEH / SHRI RAM /COPELAND Notes :- (a) Old compressor taken down/ removed shall be replaced with the same make.(b) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer as one to one replacement. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. Supporting documents for replacement from manufacturer/ dealer alongwith warranty certificate and paid vouchers shall be furnished by the Contractor before claiming payment.
Supply only starting capacitor suitable for fan/blower motor upto 3 TR walk in cooler/cold storage in replacement ,all as specified and as directed.Make EPCOS/Keltron
Supply only running capacitor suitable for fan/blower motor upto 3 TR walk in cooler/cold storage in replacement,all as specified and as directed.Make EPCOS/Keltron
Supply only control contactor, suitable for walk in cooler/cold storage of, 3TR capacity upto 32Amps ML 2 in replacement, all as specified and as directed.Make L&T equivalent in Schneider/Siemens
Supply only remote sensing unit/assembly suitable for walk in cooler/cold storage of, 3TR AC corded/ cordless with PCB board in replacement ,complete all as specified and as directed.
Supply only electric blower motor 230v for indoor walk in cooler/cold storage of capacity 3 TR in replacement,complete all as specified and directed.
Supply only electric outdoor condensor fan motor 230v for walk in cooler/cold storage of capacity 3 TR in replacement,complete all as specified and directed.
Supply only door hinges of the walk in cooler 3 TR made by steel suitable as per existing in replacement, all as specified and as directed.
Supply only door handle of the walk in cooler 3 TR made by steel suitable as per existing in replacement, all as specified and as directed.
Supply only LED light fitting 15W Surface mounted with white powder coated aluminium housing with integrated electronic driver for inside walk in cooler in replacement , complete all as specified and as directed. Crompton model LCSFR3-25-CDL equivalent model in PHILIPS/WIPRO/BAJAJ.
Supply only MCB TPN of 63A,'C' curve, 10KA rupturing capacity in replacement ,all as specified and as directed.
Supply only electric blower motor 430v for AHU, ductable type AC of capacity 8.5 TR in replacement,complete all as specified and directed.
Supply only Electric exhaust fan motor 230v for AHU, ductable type AC of capacity 8.5 TR in replacement,complete all as specified and directed.
Supply only Fan belt for AHUs of size/model B/50 suitable as per existing capacity 11 TR in replacement,complete all as specified and directed.Make Fenner
Supply only fan belt for AHUs of size/model B/50 suitable as per existing capacity 8.5 TR in replacement ,complete all as specified and directed.Make Fenner
Supply only driving belt as per existing size for the compressor driving motor / AHU driving motor for 8.5/11 TR in replacement,complete all as directed by Engineer- in-charge.
Supply only discharge filter,5 micron,of suitable size for AHUs of different locations of 8.5/11TR in replacement,all as specified and directed.
Supply only Suction filter,10 micron,of suitable size for AHUs of different locations of 8.5/11TR in replacement,all as specified and directed.
Supply only Nitrile rubber 19mm and aluminium cladding 13mm for duct insulation in replacement all as specified and directed.
Supply only filters suitable for indoor ductable Acs 5.5/7.5/8.5/11 TR capacity as per existing size in replacement all as specified and directed.
Supply only AC drain hose outlet pipe of standard size 0.75" fixed as in replacement ,all as specified and directed.Material-Corrugated Flexible Plastic. Note :- The Fixing / Labour charges of item no 8-39 and 41-62 deemed to be included in the rate quoted of item Sl no 1-7and 40.
M/S Bhagyawanticonstruction
mahadevi Enterprises
Glacier Cooling Solutions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .