| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.0 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹37.1 L+₹3,522.13 (0.10%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹47.4 L+₹10.4 L (28.0%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹57.7 L+₹20.7 L (55.8%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | 4 | Rejected-Finance Not being lowest |
Tender Value
₹43.9 L
EMD Value
₹88,000
Closing Date
18 Mar 2022, 6:00 pmClosed
HQ CWE Agra
112 Taj Road Agra Cantt
PROVN OF OPEN TRG SHED ( 40 M X 15 M) FOR TRG OF TPS UNDER GE (EAST) AGRA
2022_MES_509011_1
84240/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class D category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE East Agra
₹88,000
Yes
31 Mar 2022
18 Feb 2022
25 Mar 2022
18 Feb 2022
18 Mar 2022
4 Mar 2022
18 Feb 2022 - 25 Feb 2022
Amount
M & L for surface excavation n. exc 30 cm deep and averaging 15 cm deep & getting out in soft/loose soil complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface of broken bricks aggregates , complete all as specified and directed.
Rolling of soling of broken boulders or quarried stone not exc 15 cm thickness with power roller exc 8 tonne n. exc 12 tonne complete all as specified and directed.
M&L 75 mm thick PCC 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in floor with mixing of Ironite or other wear proof topping, laid in alternate bay incl necessary form work , finishing surface even and smooth without using extra cement complete all as specified and as directed.
M & L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and as directed.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for steel work as in tubular truss incl special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 gde st-240,including gusset plate pole etc complete all as specified and directed.
M&L for rolled sections as in roof trusses (framed),trussed,purlins,crane gantries,rails and fastenings and heavy bracket framing(beam,tee,angle,channel or flat sections) including distance pieces,cleats etc confriming to Fe-410 -w (Gde-E-250) quality -B complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of new steel surface complete all as specified and as directed.
Supply & fix purpose made screw bolts with hexogonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexogonal or square nut 16-20 mm dia and exc. 15 cm and n.exc. 22.5 cm long complete all as specified and as directed.
Material & labour for brick work in CM 1:6 with old size sub class 'B' brick & straight or curved on plain exeeding 6m mean radius complete all as specified & directed.
M&L for 12 mm thick rendering on fair faces of brick/concrete surfaces in CM 1:6, including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of plastered surfaces (previously untreated) of walls applying two coats of cement base paint over a coat of primer on walls complete all as specified and directed.
M & L for returning, filling in, earth including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
M & L for removing excavated material n. exc 50 m distance and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M & L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
~Ditto~ all as per item No 18 above but 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft/loose soil complete all as specified and as directed
M & L for RCC M-25 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M & L for RCC M-25 (Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed
M & L for RCC M-25 (Design Mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Use and waste for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces complete all as specified and directed.
Use and waste for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and as directed
Use and waste for form work to sides of pillars, posts, struts, columns for rough finished surface of concrete complete all as specified and as directed.
M& L for providing ironite metalic floor hardener with with flooring complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
MNR ASSOCIATES
deva engineers
Gupta Automobiles
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .