| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC Lowest rate tenderer |
| 2 | Rejected-Technical AH 73 2 5TH STREET 7TH MAIN ROAD SHANTHI COLONY ANNA NAGAR CHENNAI 600 040 | CHENNAI | TAMIL NADU | 600040 | - | - | Rejected-Technical Do not satisfied the departmental conditions |
| 3 | Rejected-Technical NO 9B FIRST FLOOR SSVK SHADES VAIDEESHWARAN NAGAR QUEEN VICTORIA ROAD POONAMELLEE CHENNAI 600 056 | THIRUVALLUR | TAMIL NADU | 600056 | - | - | Rejected-Technical Do not satisfied the departmental conditions |
| 4 | Rejected-Technical NO 41 21 PERAMBUR BARRACKS ROAD PATTALAM CHENNAI 12 | 12 | - | - | Rejected-Technical Do not satisfied the departmental conditions |
| 5 | Rejected-Technical CHENNAI 600 035 | CHENNAI | CHENNAI | TAMIL NADU | 600035 | - | - | Rejected-Technical Do not satisfied the departmental conditions |
Tender Value
₹2.7 Cr
EMD Value
₹1.4 L
Closing Date
10 Jun 2020, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10.
Construction of New building with development works for K2 Ayanavaram Police Station in Chennai city.
2020_TNPHC_165572_1
SE/CC/DB/4775/2019
Open Tender
Civil Works
Lump-sum
240 days
Ayanavaram in Chennai city
Construction of New building with development works for K2 Ayanavaram Police Station in Chennai city.
8 documents required · 8 mandatory
₹0
₹1.4 L
1 Oct 2020
30 May 2020
12 Jun 2020
30 May 2020
10 Jun 2020
30 May 2020
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
2.1) Filling sand
3.1) C.C.1:5:10 for Foundation & Basement
3.2) P.C.C. 1:2:4 for Foundation & Basement and other similar works
6.2) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
7.2) Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
9.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a. In Ground Floor / Stilt floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
10.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) b. In Ground Floor/stilt floor
c. In First Floor
d. In Second Floor
e. In Third Floor
11.2) Brick work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
12.1) Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
13.1) Filling with Excavated Earth
21.2) Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3) S & F of Magnetic door catches
25.0) M.S.Holdfast
26.0) Flooring in C.C.1:5:10
28.0) Floor plastering in C.M. 1:4, 20 mm tk.
30) Ellispattern
31.0) Weathering course
33.0) Plastering in C.M. 1:5, 12 mm tk.
34.0) Plastering in C.M. 1:4, 12 mm tk.
35.0) Spl. Ceiling plastering in C.M. 1:3, 10 mm tk.
36.0) Cement mortar Border in C.M. 1:5, 12 mm tk. a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
37.1) White washing 3 coats (slaked)
39.0) M.s Grills
40.0) Painting - New "wood work"
41.0) Painting - New "iron work"
46.0) S & F 20 mm dia Alu. Hanger Rod
47.0) S & F Alu Towel rail 75 cm long
48.0) S & F 5 pin Coat stand
49.0) S & F chromium plated 8 gauge Picture Hook
50.2) Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150 mm
50.3) Supply and planting avenue trees
50.4) Providing Tree guard
50.5) Supplying. Fabricating and erection of M.S Scheme Name board
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
53.3) C.I. Steps ( 5 kg)
55.2) Flat Back Urinal
59.2) Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm
60.0) PVC Nahani trap (4way/2way)
Electrical arrangements 72) Box type Fibre Fan hook
73.1) 6 way - D.B.
73.2) 4 way - D.B.
74.0) Charges for fixing of "Fan"
76.0) 8 SWG wire
77.3) S&F of TV/Telephone line Socket
77.4) S&F of 20mm dia PVC pipe for TV/Telephone line
78.0) Earthing Station IS3043 (Type I)
86.0) Anti termite treatment
112.0) S & F of Exhaust Fan 300 mm dia
238.0) Anticorrosive treatment for steel grills
ANNEXURE 2.15) Supplying and filling stonedust
8.2.3.1) Standardised concrete Mix M30 Grade Concrete a. In Foundation and basement
b. In Stilt / Ground Floor
c. In First Floor
d. In Second Floor
e. In Third floor
f. In Fourth floor
15.4) Cuddappa slab 20 mm tk.for C/B slab. a. Ground floor
b. In First floor
c. In Second floor
d. In Third floor
15.5) Cuddappa slab 40 mm tk.for C/B slab. a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.Vertical wall
21.5.2.2) Supply and Fixing Solid UPVC door Shutter with frame
21.6.1.1) R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm using M30 grade (with out vibrating charges) a. 900 x 2100 mm
22.3.3) T.W. frame & TW styles & rails with BWR double leaf shutters for cup board/ ward robes including two coat enamel paint & one coat primer.
23.1.8) TW styles & rails with 9mm thick BWR single leaf shutters with brass screws of size a. 1000 x 2100 mm
23.5) Supply & Fixing of MS door (for lockup door ) MS door of Size 1000 x 2100mm
24.1) Supply & Fixing of MS ventilator of size (lockup) MS Ventilator of Size 900 x 600mm
29.8) Glazed tiles using Grout (Tile Joint Filler)
29.9) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
31.4) Finishing the top of Terrace floor with one course of solar reflective Ceramic tiles without base concrete
38.6) One coat white cement for new walls and other similar works.
38.8) Two coat of OBD over one coat white cement for inner walls
43.2.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.(Binding wire insulated with PVC)
44.2.1) Rain water harvesting using defunct borewell and providing precasted standardised concrete mix M30 grade cover slab a). Providing pit
b) Augering 30cm dia
44.6.1) PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe (UPVC special clamp)
52.1.1) Supply, laying & jointing the following pipes as per ASTM D 1785 of schedule 40 with UPVC Specials a. 32 mm dia
b. 25 mm dia
52.4) c. 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
52.9) Supply and fixing of MS clamp set of 40mm dia including transporting charge.
53.4) S & F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5) Wash Hand Basin of size 550 x400 mm
54.1.2) S & F of 15mm dia Engineering Polymer Tap (long body )
54.2.2) S & F of 15mm dia Engineering Polymer Tap (short body tap)
56.3.1) S & F of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
56.4.1) S & F of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than G.F.
57.1.1) S & F of E.W.C.(White) 500 mm with PVC SWR grade "P" or "S" TRAP
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4) Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
61.3) UPVC Non Pressure pipe of SN8 SDR 34 ( S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1) PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
62.2.1) PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal Tee
64.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (PVC Box, Fire Retarded Box) a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.(PVC Electrical Box )
66.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.(PVC Electrical Box )
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.(PVC Electrical Box )
69.2) Supplying and fixing of 15 Amps 3 pin flush type plug using ( PVC Box, Fire Retarded Box)
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Electronic Dimmer
77.5) Run off 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
80.2) 450 x 375 x 20 mm thick TW plank
82.3) Supply and Fixing 25W LED Street light with fittings
84.3) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
85.1) Supply of G.I pipe 40mm dia 'B' Class
87.1) Supplying and delivery of Three phase ELCB/RCCB
93.1) Plastering with CM 1:3, 12mm with WPC
98.5.1) TW panelled door shutter with brass fittings. c.1200x2100mm (Double leaves)
105.1) Run off 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection
105.3) Run off 4 Wires of 6 sqmm PVC insulated single core multi strand flexible copper cable with ISI mark confirming IS: 694:1990.
127) Supply, laying and jointing the following dia upvc pipe as per ASTM below ground level b.32mm dia UPVC ASTM below Ground level
156.5) Supply and erection of 125 Amps capacity floor mounting panel board (Cubical type)
171.1.2) Labour charges for the erection of submersible pumpset in borewell/openwell a) Upto 5HP
171.2.8) Supply and delivery of submersible pumpset suitable for 150mm dia borewell without panel board 50LPM X 75m head
171.2.9) Supply and delivery of 3HP open well submersible pumpset without panel board 100LPM X 75m head
207.3.1) Plastic Emulsion Paint including primer for outer walls
238.1) Anticorrosive treatment for window grills
255.6.2) Supply & fixing of bulk head fitting suitable for 12W bulb
255.7.2) Supplying and fixing of LED Bulb suitable for fixing it to pendent / bakelite battern holder a. 9 watts LED bulb
b. 12 watts LED bulb
344.2) S & F of Bevelled edge mirror 500 x 400 x 5.5mm
359.3.1) Concrete designer tiles flooring
361.5) Vitrified Tiles flooring (Ivory)
379.8.2) Granite Tiles flooring (Ruby red) 10mm thick
448.2) Providing 32mm dia PVC Tee with end cap
450) Supply and fixing of PVC 160mm dia top end cap
504) Supply and delivery of 12mm dia nylon rope
609.6.1) Supply and delivery of 150mm OD PVC Casing pipe (6kg/cm2) as per IS 12818/1992 of approved quality for borewells a) Upto 80m
609.6.2) Supply and delivery of 150mm OD PVC Ribbed screen pipes (6kg/cm2) as per IS 12818/1992 of approved quality for borewells a) Upto 80m
609.6.3) Labour Charges for inserting PVC casing pipes of 150mm dia assembly (with slots or without slots)
615.3.1) Supplying and fixing of DOL starter a) 2HP for three phase
b). 3HP for three phase
616.4.1) Supply of following HDPE pipes for Submersible pump in Borewell a) 32mm dia
619) Supply and delivery of following plumbing fittings a.32mm dia Union
b.32mm dia GI Pipe
c. 32mm dia GI bend
d. 32mm dia GI coupling
707.3.2) Supply and laying of 3 core 4Sqmm flat type copper cable
724.6) Supply and laying of 3.5C x 95Sqmm pvc armoured LTUG cable below GL
741.1.1) S & F of 20 amps DP plug & Socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection(For AC Plug) of approved / superior variety
799.1.2) Drilling of borewell any where including transportation from one place to anouther place in alluvial soil or sedmentary starts mud circulation method of 150mm dia of clay and sand a) Upto 60m depth ending below ground level
799.1.3) Drilling of borewell in hard rock areas anywhere in Tamil Nadu including transportation from one place to another place etc all complete. a) 150mm dia bore
799.2.2) Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the departmental officers. a) Upto 60m depth ending below ground level
799.3.1) Charges for developing the borewell for the entire depth with air compressor of 300cfm capacity (minimum 8 hours)
832.5.2) Supplying, fabricating and fixing in position of UPVC window/ventilator(openable) for all sizes
832.5.3) Supplying, fabricating and fixing in position of UPVC ventilator(louvered) for all sizes
958.3) Supply and installation of 10 Persons capacity Passenger Lift (Brand: Johnson / Kone/ OTIS) Car Size (1300 x 1350mm) Gearless lift - without machine room
960.3.9) Supply and fixing of brass cable gland suitable for 3.5C x 95Sqmm PVC armoured LTUG cable
960.4) Providing End termination for 3.5C x 95Sqmm PVC armoured LTUG cable
960.4.5.1) Supply & fixing of LED Tube Light of 4' long with fittings a) 4' 18 W (Crystal glass) LED
Bidder Name
K BASKARAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .