Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | ₹37.2 L Quoted ₹39.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹39.5 L+₹50,485 (1.29%)Rejected-AOC | ₹39.5 L+₹50,485 (1.29%) | L2 | Rejected-AOC Due to higher rate |
| 3 | L3₹39.9 L+₹86,705 (2.22%)Rejected-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹39.9 L+₹86,705 (2.22%) | L3 | Rejected-AOC Due to higher rate |
| 4 | L4₹41.8 L+₹2.8 L (7.23%)Rejected-AOC | ₹41.8 L+₹2.8 L (7.23%) | L4 | Rejected-AOC Due to higher rate |
| 5 | L5₹43.2 L+₹4.2 L (10.8%)Rejected-AOC 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | ₹43.2 L+₹4.2 L (10.8%) | L5 | Rejected-AOC Due to higher rate |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Jun 2021, 2:00 pmClosed
Executive Engineer
Construction Branch, Kurukshetra University Kurukshetra.
Supply, Erection, Testing and commissioning of VRV AC Plant as per DNIT of Senate Hall (Bhagwat Geeta Sadan) at Kurushetra University Kurukshetra.
2021_HRY_173603_1
KUK/Constn/2021/1
Open Tender
Electrical Works
Works
75 days
Kurukshetra Universiity Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Yes
₹1 L
Yes
17 Nov 2021
1 Jun 2021
29 Jun 2021
1 Jun 2021
28 Jun 2021
1 Jun 2021
Amount
Work detail
VRV Outdoor Units SITC of Air Cooled VRV/F units with scroll Compressor capable of modulating capacity i.e. it should be able to vary speed of the compressor as per the varying load conditions and works on R-410A with heating & cooling both. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish. The outdoor unit shall have multiple Twin Rotary/scroll compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping. Variable refrigerant volume/flow modular type air-conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor. Outdoor unit having minimum COP at 100% Load must be 4 & 50% Load it must be 6.5 at 35 deg. Outside ambient conditions. (ARI Condition). All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. All compressor shall have inverter technology i.e. outdoor units shall have all 100% inverter based compressor. Each ODU whether used individually or used to make module should have multiple compresors. (a) 22.0 HP (Make: Blue Star/O General/Toshiba/Daikin/Mitsubishi)
Indoor Units Air Handling Unit SITC of Floor mounted double skin AHU-6000 CFM @50mm SP with Pre filters, blower with motor & VFD of suitable capacity, 6RD DX cooling coil (2#-1W+1SB) with Thermal break profile having section of 42mm thick, Fire proof canvass connection (inside), Mixing Box with Extruded Aluminium Vol control dampers etc complete in all respects.
AHU accessories (Make: Edgetech/Zeco) (to be installed in AHU room on PCC foundation as per design & to be provided by civil agency)
SITC of VRV AHU kits suitable for 22.0 HP ODUs alongwith necessary hardwares & controls.
SITC of Copper ref nuts.
SITC of Corded remote controllers.
SITC of MS channel frame for VRV ODUs duly painted as per design (Make: Blue Star/O General/Toshiba/Daikin/Mitsubishi)
Copper Piping SITC of interconnecting of refrigerant copper pipe work with fittings duly insulated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with GI Cable tray & GI threaded rods with nuts & bolts. 41.3 mm (1⅝") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
34.9 mm (1⅜") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
28.6 mm (1⅛") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
22.2 mm (⅞") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
19.05 mm (¾") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
15.9 mm (⅝") dia with 19mm thick nitrile rubber insulation. (Make: Mandev/Rajco/Totaline)
Drain Piping SITC of Rigid PVC Piping complete with fittings, supports as per specifications with supports and adhesive.32mm dia (Make: Prince/Supreme)
Air Distribution SITC of Factory or site fabricated hand made duct connection pieces with GI nut bolts, nitrile gasket, GI channel & threaded rod supports of suitable sizes & at suitable intervals as per ISI specifications and relevent standards of following sizes: 22G (0.80mm) (Make: Eco duct/Zeco/Tata/SAIL)
24G (0.63mm)(Make: Eco duct/Zeco/Tata/SAIL)
SITC of External exposed ducts to be insulated with 13mm thick Class O nitrile insulation, FG cloth and two coates of Encoat paint as per design. (Make:Kflex/Aeroflex/armaflex)
SITC of Duct acoustic lining with 10 mm thick accosound & suitable adhesive and required accessories/ hardware (Make:Kflex/Aeroflex/armaflex)
SITC of Al extruded powder coated Supply Air Grills with Al extruded vol control dampers.
SITC of RA Grills- Al extruded powder coated without VCD as per design.
SITC of Fire Dampers with actuators suitable for 120mts rating RA Grills- Al extruded powder coated without VCD as per design.
GSS Fire dampers of 16 Gauge body & louvers complete with necessary linkage suitable for 1.5hr fire rating
Actuator Assembly with control panel sensor etc. (Pineair/Caryaire/Uniaire)
Control & Transmission Wiring SITC of control cum transmission wiring of 1.0 mm² x 2 core copper shielded in suitable conduits between indoor and out door unit with proper work like manner.
SITC of Fresh Air system with Al powder coated louvers and bird screen as per the system design.
SITC of Main Electrical Distibution Panel for AHU, VRV ODUs in the AHU room at terrace as per design and specifications. The panel shall be made out of 1.6mm thick CRCA sheet duly powder coated and vermin proof floor mounted type with front and back openable compartments, having Al strip around it for earthing connections on both sides of the panel. MCCB Make ABB / L&T/siemens Incoming MCCB-200A TPN Volt & Ammeter (Digital) of suitable capacity, CTs, Status Indicators, Al Bus Bar duly covered with coloured sleeves, Control fuses etc. Outgoing: Suitable cap. MCBs for VFD for AHU motors Suitable cap. MCBs for VRV ODUs-4# Dummy Box if any
Cabling: SITC of Power cabling with PVC armoured copper conductor complete with saddles/lugs etc of sizes: 25mm² x 3½ core- for VRV ODUs (Make: Havells/Polycab/RR)
1.5mm² x 4 core- for AHUs (Make: Havells/Polycab/RR)
SITC of main power cable with PVC Armoured aluminium conductor complete with saddles/lugs etc. of sizes: 185mm² x 3½ core (Make: Havells/Polycab/RR)
Supply & fixing of GI Cable tray of 16-18 gauge suitable with necessary hardware like hanging GI threaded rods, fasteners, joint clamp etc of sizes:- 50 x 150 x 50 mm
Supply & fixing of GI earthing strips of size 25 mm x 3 mm installed between main panel to all the ODUs.
Supply & fixing of GI Earth wire 8 SWG
Earthing with G.I. earth plate of size 600mm x 600mm x 6mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
SITC of Insulated room at the roof top for the AHUs. It shall be made of PPGI sheets of suitable capacity having PUF (40kg/m² density wall thickness of 60mm complete with roof (60/30mm), window and air tight door lockable door, Fresh air cut out, all the necessary hardware, profile, margins etc. duly sealed with suitable sealant to give it a smooth finish. (Make: Bansal Generation/Bnal)
SITC of Minor civil work incl. making of cut outs for ducts/pipes & making them good complete in all resepcts as required.
Buy Back credit for the existing units (The job includes the dismantling & removal of the 9#x3.0TR Old Fedders Lloyd ductables alongwith accessories like duct pcs, MS angle frames, electricals etc. on as is where is basis)
SMD SOLUTIONS
Blue Star Limited
Chill Point Engineers Pvt Ltd
Mark Engineering Inc.
modern cooling solution
MVAC ENGINEERS
Hemcool Engineers
Aircon Technique Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .