Executive Engineer, Purba Medinipur Electrical Div
Tamluk, Purba medinipur
Installation of AC Machines and Fire Detection System at DEIC Contai SDH in Nandigram HD SITC of AC machines. 2nd call
2024_WBPWD_745776_1
WBPWD/EE/PMED/NIQ-22/24-25(2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Contai
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,791
Office of the Executive Engineer Purba Medinipu
4 Dec 2025
5 Sept 2024
27 Sept 2024
5 Sept 2024
25 Sept 2024
10 Sept 2024
9 Sept 2024
Amount
SITC of 1.0 Tr capacity Rated cooling capacity 18000 Btu / hr. split type Air conditioner machines suitable for operating at rated AC power supply-230V-1ph-50 Hz, 2 / 3 star of refrigerent R-32 / R-410A. The Ac machine (both IDU & ODU) should be installed with suitable iron bracket, fixing materials.(Make - Mitsubishi Electric / O-General/Mitsubishi Heavy Duty) [Nursing/Nutri,ECG,Langauge,Psycho & Laboratory]
SITC of 1.5 Tr capacity Rated cooling capacity 18000 Btu / hr. split type Air conditioner machines suitable for operating at rated AC power supply-230V-1ph-50 Hz, 2 / 3 star of refrigerent R-32 / R-410A. The Ac machine (both IDU & ODU) should be installed with suitable iron bracket, fixing materials.(Make - Mitsubishi Electric / O-General/Mitsubishi Heavy Duty) [S.Intrigration]
SITC of 2.0 Tr capacity Rated cooling capacity 18000 Btu / hr. split type Air conditioner machines suitable for operating at rated AC power supply-230V-1ph-50 Hz, 2 / 3 star of refrigerent R-32 / R-410A. The Ac machine (both IDU & ODU) should be installed with suitable iron bracket, fixing materials.(Make - Mitsubishi Electric / O-General/Mitsubishi Heavy Duty) [ Early Intervention therapy, Vision Impairment, Hearing Impairment, Sound Proff area, Examination & Dental ]
Supply, Installation & commissioning of hard/soft copper (0.6mm) refrigeration pipeline, with 9 mm nitrile rubber tube Insulation on following sizes of suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex, complete with fittings, elbows, bends, supporting arrangement on walls (Make- Ryoku/Rajco/Mandev).
S & F of Control Cabling from starter to ODUand IDU of AC machine a) 1.1 KV gr. Single core stranded PVC insulated 4 Core 2.5 sq. mm. Cu. Wire. Make- Ploycab/Finolex / RR Kabel.
b) 1.1 KV gr. Single core stranded PVC insulated 3 Core 2.5 sq. mm. Cu. Wire. Make- Ploycab/Finolex / RR Cabel.
Supply & laying Drain Water piping work by PVC / HDPE hard pipe of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.Make- Oriplast / Supreme
a) 19mm dia PVC
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (45 mm x 45 mm x 40 mm) for making platform for installation of outdoor unit of 1.0 /1.5/ 2.0 TR concealed split air conditioner at roop top of the building as per requrement (measureable as per base on platfrom size of Sq.ft)
Charges for scaffolding,carrying,lifting & shifting of arrangement incl. lifting for outdoor & indoor units.
Supply of Single-Phase timer for controlling 1 No. single-ph AC M/C(concealed split) of size 1/1.5/2 Tr. Consisting of the following: a) 8 way SPN DB-1 No.-Double Door(Make:L&T/ Simence), b) Astronomical Timer, 0-999hrs (Make: L&T), c) DP MCB 250V/32A-1No.(Make: L&T), d) 3-pole power contactor of required rating-1No.(Make: L&T) , e) DB Locking arrangement must be there f) Push Bottom ON/OFF switch individual outer side of DB (There must be bypass mechanism and indication for ON/OFF by indicating Lamp of the AC m/c unit attached to it.)(For Single Air Conditioner Machine )
Supply of Single-Phase timer for controlling 1 No. single-ph AC M/C(concealed split) of size 1.5/2 Tr. Consisting of the following: with 6A 2nos MCB (approve make) a) 12 way SPN DB-1 No.-Double Door(Make:L&T/ Simence/legrand), b) Astronomical Timer, 0-999hrs (Make: L&T), c) DP MCB 250V/32A-1No.(Make: L&T), d) 3-pole power contactor of required rating-2 No.(Make: L&T) , e) DB Locking arrangement must be there f) Push Bottom ON/OFF switch individual outer side of DB (There must be bypass mechanism and indication for ON/OFF by indicating Lamp of the AC m/c unit attached to it.)(For Single phase Double Air Conditioner Machine)
M.S. COOLING & ENGINEERING CO. (BID ID -5631271)
ANIKET COOLING AND REFRIGERATION CO (BID ID -5631321)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .