Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹4.4 CrAccepted-Finance | ₹4.4 Cr | 1st | Accepted-Finance 1st |
| 2 | Rejected-Technical | - | - | Rejected-Technical Experience not attech as per TD |
Tender Value
₹4.6 Cr
EMD Value
₹9.3 L
Closing Date
29 Dec 2025, 5:00 pmClosed
SE KOTPUTLI
SE KOTPUTLI
Work of construction of Sources rising main pipelines RCC Reservoir internal village distribution pipeline and FHTC including one year Defect Liability period of Village SHAHJAHANPUR under Subdivision Neemrana under JJM in the jurisdiction of PHED
2025_PHCJA_519078_1
SEKOTPUTLI-33/2025-26
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Percentage
270 days
BEHROR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
MD RISL
₹9.3 L
Yes
25 Mar 2026
10 Dec 2025
30 Dec 2025
10 Dec 2025
29 Dec 2025
10 Dec 2025
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Drilling Work | - | - | - | - |
| 2 | Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. Nominal bore 200 mm dia. (PHED 2021/2.1.4) | 110 | Mtr | 1,355 | ₹1,49,050 |
| 3 | Add 15 % extra on above item for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.(PHED 2021/2.1.5) | 10 | Mtr | 203 | ₹2,030 |
| 4 | Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. Nominal bore 200 mm dia. (PHED 2021/2.3.2) | 170 | Mtr | 1,121 | ₹1,90,570 |
| 5 | Add 15 % extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.(PHED 2021/2.3.3) | 90 | Mtr | 168.15 | ₹15,133.5 |
| 6 | Add 30 % extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr , rate shall be applicable for only extra depth beyond 200 mtr.(PHED 2021/2.3.4) | 80 | Mtr | 336.3 | ₹26,904 |
| 7 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes . 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (PHED 2021/2.11.2) | 111 | Mtr | 2,630 | ₹2,91,930 |
| 8 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm. dia.(PHED 2021/2.23.3) | 1 | Each | 850 | ₹850 |
| 9 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore. (PHED 2021/2.12.3) | 24 | Mtr | 273 | ₹6,552 |
| 10 | Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. (PHED 2021/2.15) | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_926180.xls
BOQ • 0.40 MB
TD33.pdf
Tender Documents • 18.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].