| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAdmitted-Finance 19 20 VARDHMAN INDUSTIRAL ESTATE LBS MARG VIKHROLI WEST MUMBAI MAHARASHTRA 400083 | MUMBAI SUBURBAN | MAHARASHTRA | 400083 | ₹5.0 Cr | L1 | Admitted-Finance |
| 2 | L1₹5.2 CrAdmitted-Finance MEHTA MARKET MAIN ROAD SURENDRANAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | ₹5.2 Cr | L1 | Admitted-Finance |
| 3 | L1₹6.2 CrAdmitted-Finance | ₹6.2 Cr | L1 | Admitted-Finance |
| 4 | L1₹7.4 CrAdmitted-Finance | ₹7.4 Cr | L1 | Admitted-Finance |
| 5 | L1₹9.7 CrAdmitted-Finance 4 CHAMPAKLAL UDYOG BHAVAN SION EAST MUMBAI MAHARASHTRA 400022 MH27B0001360 27AADCN3668F1ZC R M GST TAX GST TAX INVOICE TO BE RAISED IN THE NAME OF BUYER | MUMBAI | MAHARASHTRA | 400022 | ₹9.7 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHAH BHOGILAL JETHALAL AND BROS L1 | NEWAGE FIRE PROTECTION INDUSTRIES PVT LTD L1 | M/s. NewAge Fire Fighting Co. Ltd. L1 | HD FIRE PROTECT PVT.LTD. L1 | Vimal Fire Controls Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00SUPPLY OF HIGH-VOLUME LONG-RANGE FOAM CUM WATER MONITOR (HVLRM) for (PFCC / GDS / MS BLOCK) UNIT FOR NREP (Overall Lowest on Landed Cost Evaluation) | ||||||||
| 1.01 | UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Jet Ratio Comptroller Pump (JRCP), Pick-up Tube, 1 No. UL listed Foam Concentrate Container (Tote) of 1000 Liters capacity filled with UL listed AFFF 3% Foam Concentate,1 No. 2-1/2" dia hose of 15m long for connecting JRCP with Monitor Nozzle for foam solution supply to monitor nozzle, Monitor Nozzle having suitable male inlet for foam solution induction through Jet Ratio Comptroller Pump (JRCP) etc. as per attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1). | 36 | Nos. | 1,29,95,600 ₹1,29,95,600 | 3,76,56,575 ₹3,76,56,575 | 1,13,46,300 ₹1,13,46,300 Lowest | 2,71,17,000 ₹2,71,17,000 | 1,15,02,000 ₹1,15,02,000 |
| 1.02 | UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Tower Mounted and Remote Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Local Control Panel with mounting bracket and canopy (1 No.), Wireless Remote Controller Unit having about 75m operating range from the local control panel (1 No.), 8" Size Motor Operated Gate Valve (MOV) with Actuator (1 No.) (refer attached Piping Material Specification for technical MOC and coating details of Gate Valve - TK-1ZZZA-PI-SPE-0002_D2), Vertical Foam Concentrate Storage Tank (SS 304) of 1000 lit capacity filled with 3% AFFF Foam Concentrate (1 No.) fabricated as per ASME code Section VIII, Div.-I with built-in Canopy fro protecting from direct sunlight & weather conditions (1 No.), Pick-up Tube of suitable size and 4m long to suck foam concentrate from foam tank (to be kept near the monitor on top of the platform) to monitor nozzle (1 No.), Limit Switch (1 No.) to be installed on the foam concentrate tank and to be connected through cabling with Local Control Panel of the Monitor for monitoring of foam concentrate level in the tank, all required Junction Boxes, Power & Control Cable, Cable Trays, Cable Glands, other cabling accessories etc. Bidder shall consider the cabling distance between monitor (and level switch also) on the top of platform & Local Control Panel as about 200 m (approx.) and the cabling distance between the Local Control Panel and the MOV (at ground level) as 200 m (approx.) also and supply the cabling accordingly. All electrical & instrumentation items of this equipment shall be suitable for hazardous area classification Zone-1, Gas Group IIA/IIB/IIC, T3 as minimum. Weather protection for control panel enclosure shall be mini-mum IP65.
Bidder shall refer the scheme of the remote operated monitors in the attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1)'.
Bidder shall note that the Foam Concentrate Tank shall be located near the monitor on the top platform of structural tower. Foam concentrate induction shall be done from this tank through the Pick-up Tube. The tank shall be designed and fabricated as per ASME code Section VIII, Div.-I. The tank shall be fitted with nozzle for foam concentrate supply inlet (2” line) from top, nozzle for pick-up tube entry from top, nozzle for vent connection from top, nozzle of connecting a level switch from the top and nozzle for drain connection with isolation valve at bottom. The tank shall be connected with a rigid piping (SS 304) of 3" size for refilling purpose and shall be routed from the tank filling nozzle to the ground level near road edge fitted with a 1-Way Fire Brigade Connection of SS 303 material. This SS piping shall not be in the scope of supply of the bidder.
Bidder to submit separate technical data sheet for the tank along with their offer. | 18 | Nos. | 4,59,50,000 ₹4,59,50,000 | 5,50,06,750 ₹5,50,06,750 | 3,81,24,000 ₹3,81,24,000 | 4,42,25,460 ₹4,42,25,460 | 3,70,26,000 ₹3,70,26,000 Lowest |
| 1.03 | 1-Way Fire Brigade Connection, with 1 No. 63 mm NB male instantaneous inlet and 80 mm NB Flanged Outlet, MOC - SS 304. | 19 | Nos. | 85,500 ₹85,500 | 1,29,438 ₹1,29,438 | 53,200 ₹53,200 Lowest | 1,42,500 ₹1,42,500 | 99,750 ₹99,750 |
| 1.04 | AFFF 3% Foam Concentrate to be supplied with 200 Liter capacity drum, UL Listed. | 55 | Nos. | 18,70,000 ₹18,70,000 | 19,81,260 ₹19,81,260 | 11,00,000 ₹11,00,000 | 18,70,000 ₹18,70,000 | 9,90,000 ₹9,90,000 Lowest |
| 2.00SPARE PARTS FOR HIGH VOLUME LONG RANGE FOAM CUM WATER MONITORS (HVLRM) (PFCC / GDS / MS BLOCK) UNIT FOR NREP PROJECT. | ||||||||
| 2.10SPARE PARTS for UL Listed / FM Approved 1000 - 15000 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, including the following items: | ||||||||
| 2.10 | Rubber ‘O’ ring kit. (recommended 02 kits per monitor) | 4 | Set | 5,600 ₹5,600 | 1,45,260 ₹1,45,260 | 18,000 ₹18,000 | 2,000 ₹2,000 | 1,440 ₹1,440 Lowest |
| 2.10 | Pressure Gauge | 4 | Nos. | 14,400 ₹14,400 | 46,402 ₹46,402 | 23,200 ₹23,200 | 16,000 ₹16,000 | 4,320 ₹4,320 Lowest |
| 2.10 | Gland | 4 | Nos. | 2,200 ₹2,200 Lowest | 10,087 ₹10,087 | 11,200 ₹11,200 | 4,000 ₹4,000 | 2,520 ₹2,520 |
Tender Value
Refer Docs
Closing Date
22 Dec 2025, 3:00 pmClosed
Mr. Amit Borkar
thyssenkrupp Uhde India Pvt Ltd Vikhroli Mumbai India
SUPPLY OF HIGH VOLUME LONG-RANGE FOAM CUM WATER MONITOR (HVLRM) for (PFCC / GDS/ MS BLOCK) UNIT FOR NREP
2025_NRL_885254_1
TK-1ZZZA-MP-RFQ-0198
Open Tender
Miscellaneous Goods
Supply
240 days
Numaligarh Refinery Limited Assam
As per Tender
8 documents required · 8 mandatory
₹0
Exempted
6 Feb 2026
13 Nov 2025
23 Dec 2025
13 Nov 2025
22 Dec 2025
27 Nov 2025
13 Nov 2025 - 25 Nov 2025
SUPPLY OF HIGH-VOLUME LONG-RANGE FOAM CUM WATER MONITOR (HVLRM) for (PFCC / GDS / MS BLOCK) UNIT FOR NREP (Overall Lowest on Landed Cost Evaluation)
UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Jet Ratio Comptroller Pump (JRCP), Pick-up Tube, 1 No. UL listed Foam Concentrate Container (Tote) of 1000 Liters capacity filled with UL listed AFFF 3% Foam Concentate,1 No. 2-1/2" dia hose of 15m long for connecting JRCP with Monitor Nozzle for foam solution supply to monitor nozzle, Monitor Nozzle having suitable male inlet for foam solution induction through Jet Ratio Comptroller Pump (JRCP) etc. as per attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1).
UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Tower Mounted and Remote Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Local Control Panel with mounting bracket and canopy (1 No.), Wireless Remote Controller Unit having about 75m operating range from the local control panel (1 No.), 8" Size Motor Operated Gate Valve (MOV) with Actuator (1 No.) (refer attached Piping Material Specification for technical MOC and coating details of Gate Valve - TK-1ZZZA-PI-SPE-0002_D2), Vertical Foam Concentrate Storage Tank (SS 304) of 1000 lit capacity filled with 3% AFFF Foam Concentrate (1 No.) fabricated as per ASME code Section VIII, Div.-I with built-in Canopy fro protecting from direct sunlight & weather conditions (1 No.), Pick-up Tube of suitable size and 4m long to suck foam concentrate from foam tank (to be kept near the monitor on top of the platform) to monitor nozzle (1 No.), Limit Switch (1 No.) to be installed on the foam concentrate tank and to be connected through cabling with Local Control Panel of the Monitor for monitoring of foam concentrate level in the tank, all required Junction Boxes, Power & Control Cable, Cable Trays, Cable Glands, other cabling accessories etc. Bidder shall consider the cabling distance between monitor (and level switch also) on the top of platform & Local Control Panel as about 200 m (approx.) and the cabling distance between the Local Control Panel and the MOV (at ground level) as 200 m (approx.) also and supply the cabling accordingly. All electrical & instrumentation items of this equipment shall be suitable for hazardous area classification Zone-1, Gas Group IIA/IIB/IIC, T3 as minimum. Weather protection for control panel enclosure shall be mini-mum IP65. Bidder shall refer the scheme of the remote operated monitors in the attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1)'. Bidder shall note that the Foam Concentrate Tank shall be located near the monitor on the top platform of structural tower. Foam concentrate induction shall be done from this tank through the Pick-up Tube. The tank shall be designed and fabricated as per ASME code Section VIII, Div.-I. The tank shall be fitted with nozzle for foam concentrate supply inlet (2” line) from top, nozzle for pick-up tube entry from top, nozzle for vent connection from top, nozzle of connecting a level switch from the top and nozzle for drain connection with isolation valve at bottom. The tank shall be connected with a rigid piping (SS 304) of 3" size for refilling purpose and shall be routed from the tank filling nozzle to the ground level near road edge fitted with a 1-Way Fire Brigade Connection of SS 303 material. This SS piping shall not be in the scope of supply of the bidder. Bidder to submit separate technical data sheet for the tank along with their offer.
1-Way Fire Brigade Connection, with 1 No. 63 mm NB male instantaneous inlet and 80 mm NB Flanged Outlet, MOC - SS 304.
AFFF 3% Foam Concentrate to be supplied with 200 Liter capacity drum, UL Listed.
SPARE PARTS FOR HIGH VOLUME LONG RANGE FOAM CUM WATER MONITORS (HVLRM) (PFCC / GDS / MS BLOCK) UNIT FOR NREP PROJECT.
SPARE PARTS for UL Listed / FM Approved 1000 - 15000 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, including the following items:
Rubber ‘O’ ring kit. (recommended 02 kits per monitor)
Pressure Gauge
Gland
Key for Worm
Grease Nipple
SPARE PARTS for UL Listed / FM Approved 1000 - 15000 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, including the following items:
Rubber ‘O’ ring kit. (recommended 02 kits per monitor)
Pressure Gauge
Gland
Key for Worm
Grease Nipple
Limit Switches
Relay
Junction Box
Proxy Sensor
Push Buttons
Indication Lamp
Spare Parts for Motor Operated Valve (MOV) including but not limited to Gland Packing, O-rings, bearings, gaskets, electronic card for actuator, seat, seat ring, maintenance kit etc.
SPARE PARTS - 1-Way Fire Brigade Connection, with 1 No. 63 mm NB male instantaneous inlet and 80 mm NB Flanged Outlet, MOC - SS 304.
SPARE PARTS - AFFF 3% Foam Concentrate to be supplied with 200 Liter capacity drum, UL Listed.
Site Supervision Services rection/commissioning of remote operated tower monitors
BoQ_Ver3.0
Notes:( BOQ for Built in Import Content) 1. Bidder shall indicate Built in CIF Value along with Quantities of goods and its description. 2. Bidder has to ensure that Currency quoted in this format shall be same with the currency quoted in the main price schedule format for the built in CIF Value. 3. Bidder to consider the input Tax Credit of IGST available at their end (In case of import of raw materials / components) in their quoted prices. 4. The CIF Values indicated by the bidder shall be deemed to be the maximum value(s) for the purpose of variation in Basic Custom Duty and Social Welfare Surcharge.
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - BUILT IN IMPORT CONTENT (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SUPPLY OF HIGH-VOLUME LONG-RANGE FOAM CUM WATER MONITOR (HVLRM) for (PFCC / GDS / MS BLOCK) UNIT FOR NREP (Overall Lowest on Landed Cost Evaluation)
UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Jet Ratio Comptroller Pump (JRCP), Pick-up Tube, 1 No. UL listed Foam Concentrate Container (Tote) of 1000 Liters capacity filled with UL listed AFFF 3% Foam Concentate,1 No. 2-1/2" dia hose of 15m long for connecting JRCP with Monitor Nozzle for foam solution supply to monitor nozzle, Monitor Nozzle having suitable male inlet for foam solution induction through Jet Ratio Comptroller Pump (JRCP) etc. as per attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1).
UL listed / FM approved 1000 - 1500 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Tower Mounted and Remote Operated Type, MOC-SS 316, 150 mm NB Flanged Inlet, ASME B 16.5 CL. - 150, FF, including but not limited to Local Control Panel with mounting bracket and canopy (1 No.), Wireless Remote Controller Unit having about 75m operating range from the local control panel (1 No.), 8" Size Motor Operated Gate Valve (MOV) with Actuator (1 No.) (refer attached Piping Material Specification for technical MOC and coating details of Gate Valve - TK-1ZZZA-PI-SPE-0002_D2), Vertical Foam Concentrate Storage Tank (SS 304) of 1000 lit capacity filled with 3% AFFF Foam Concentrate (1 No.) fabricated as per ASME code Section VIII, Div.-I with built-in Canopy fro protecting from direct sunlight & weather conditions (1 No.), Pick-up Tube of suitable size and 4m long to suck foam concentrate from foam tank (to be kept near the monitor on top of the platform) to monitor nozzle (1 No.), Limit Switch (1 No.) to be installed on the foam concentrate tank and to be connected through cabling with Local Control Panel of the Monitor for monitoring of foam concentrate level in the tank, all required Junction Boxes, Power & Control Cable, Cable Trays, Cable Glands, other cabling accessories etc. Bidder shall consider the cabling distance between monitor (and level switch also) on the top of platform & Local Control Panel as about 200 m (approx.) and the cabling distance between the Local Control Panel and the MOV (at ground level) as 200 m (approx.) also and supply the cabling accordingly. All electrical & instrumentation items of this equipment shall be suitable for hazardous area classification Zone-1, Gas Group IIA/IIB/IIC, T3 as minimum. Weather protection for control panel enclosure shall be mini-mum IP65. Bidder shall refer the scheme of the remote operated monitors in the attached 'Technical Specification for Fire Fighting & Safety Equipment (TK-1ZZZA-SA-DAT-0001_A1)'. Bidder shall note that the Foam Concentrate Tank shall be located near the monitor on the top platform of structural tower. Foam concentrate induction shall be done from this tank through the Pick-up Tube. The tank shall be designed and fabricated as per ASME code Section VIII, Div.-I. The tank shall be fitted with nozzle for foam concentrate supply inlet (2” line) from top, nozzle for pick-up tube entry from top, nozzle for vent connection from top, nozzle of connecting a level switch from the top and nozzle for drain connection with isolation valve at bottom. The tank shall be connected with a rigid piping (SS 304) of 3" size for refilling purpose and shall be routed from the tank filling nozzle to the ground level near road edge fitted with a 1-Way Fire Brigade Connection of SS 303 material. This SS piping shall not be in the scope of supply of the bidder. Bidder to submit separate technical data sheet for the tank along with their offer.
1-Way Fire Brigade Connection, with 1 No. 63 mm NB male instantaneous inlet and 80 mm NB Flanged Outlet, MOC - SS 304.
AFFF 3% Foam Concentrate to be supplied with 200 Liter capacity drum, UL Listed.
SPARE PARTS FOR HIGH VOLUME LONG RANGE FOAM CUM WATER MONITORS (HVLRM) (PFCC / GDS / MS BLOCK) UNIT FOR NREP PROJECT.
SPARE PARTS for UL Listed / FM Approved 1000 - 15000 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, including the following items:
Rubber ‘O’ ring kit. (recommended 02 kits per monitor)
Pressure Gauge
Gland
Key for Worm
Grease Nipple
SPARE PARTS for UL Listed / FM Approved 1000 - 15000 - 2000 GPM Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (HVLRM), Stand Post Mounted, Manually Operated Type, including the following items:
Rubber ‘O’ ring kit. (recommended 02 kits per monitor)
Pressure Gauge
Gland
Key for Worm
Grease Nipple
Limit Switches
Relay
Junction Box
Proxy Sensor
Push Buttons
Indication Lamp
Spare Parts for Motor Operated Valve (MOV) including but not limited to Gland Packing, O-rings, bearings, gaskets, electronic card for actuator, seat, seat ring, maintenance kit etc.
SPARE PARTS - 1-Way Fire Brigade Connection, with 1 No. 63 mm NB male instantaneous inlet and 80 mm NB Flanged Outlet, MOC - SS 304.
SPARE PARTS - AFFF 3% Foam Concentrate to be supplied with 200 Liter capacity drum, UL Listed.
Site Supervision Services rection/commissioning of remote operated tower monitors
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Part_II_Section-1.rar
Tender Documents • 26.07 MB
Part_II_Section-2.rar
Tender Documents • 26.52 MB
BOQ_930508.xls
BOQ • 0.31 MB
Part_I.rar
Tender Documents • 24.17 MB
Bid_Documents_HVLRM.xls
Tender Documents • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .