Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹7.7 Cr | L1 | Accepted-AOC Lowest and Reasonable |
| 2 | L2₹8.6 Cr+₹90.2 L (11.7%)Rejected-Finance | ₹8.6 Cr+₹90.2 L (11.7%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹8.9 Cr+₹1.2 Cr (16.0%)Rejected-Finance | ₹8.9 Cr+₹1.2 Cr (16.0%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹9.3 Cr+₹1.6 Cr (21.0%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹9.3 Cr+₹1.6 Cr (21.0%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹9.7 Cr+₹2.0 Cr (26.4%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹9.7 Cr+₹2.0 Cr (26.4%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹8.2 Cr
EMD Value
₹7.3 L
Closing Date
4 Sept 2023, 6:00 pmClosed
C
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
PROVN OF SINGLE LIVING ACCN FOR 5 JCOS AND 173 ORS AT ALWAR MIL STATION
2023_MES_593274_1
80852
Open Tender
Civil Works
Lump-sum
550 days
GE ALWAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
Yes
GE Alwar
₹7.3 L
Yes
27 Sept 2023
6 May 2023
6 Sept 2023
28 Jul 2023
4 Sept 2023
29 Aug 2023
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT etc." as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "FENCING AND GATE" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "SUMMER APPLIANCES AND AIR CONDITIONING" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for " HOT WATER SUPPLY " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for " SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Sch 'A' Sec-XIII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XII (SITE CLEARANCE, EXCAVATION & EARTH WORK schedule).
INTERNAL ELECTRIFICATION S&F for highly efficient LED Bulbs, 9 watts complete all as specified and directed.
Material and labour for FRLS single core PVC insulated and unsheathed multistandard copper conductor and incl PVC rigid non-metallic concealed conduit of size 20/25 mm dia medium duty, ISI marked to be terminated in pressed steel terminal boxes with 3mm thick Bakelite sheet top cover incl 1.5 sqmm (22/.3) PVC insulated and unsheathed FRLS single core multistandard copper earth continuity conductor controlled complete all as specified and directed of following complete all as specified and directed. Note :- (i) Unit rate inserted rates inclusives of any type of MS Sunken boxes and Modular metal flush boxes types all type of enclosure & cover plate any size as required as per site requirment. (ii) Circuit wire from DB to switch boards shall be included in unit rate .
(a) One light point controlled by one way switch with cables 1.5 mm² size
(b) One fan and exhaust fan point controlled by one way switch with cables 1.5 mm² size.
(c) One three Pin 5A socket outlet, independent board, with cables1.5 mm² size.
(d) One three Pin 5A socket outlet, same board, with cables 1.5 mm² size.
(e) One three pin 16 A socket outlet, independent, with cables 2.5 mm² size
(f) One light point controlled by two way switch with cables 1.5 mm² size
S&F for LED study lamp 5 watt LES 3000K Innova Neo Surface mounted spot light in mat finish for premium aesthetics complete all as specified and directed Make Havells Cat Part No LHEEGBPH1W005 of equivalent in Wipro cat part No. D180640 or Philips cat part No. 31448
S&F for Sheet metal enclosure distribution board VTPN, 4 Way, 415 volt, double door powder coated, protection class IP-54, neutral bar, mechanical impact strength IK-09 suitable for mounting MCB & MCCBs DBs confirming to IS-13032, IS-8632, BS5484 with min 200 Amp rating copper bus bar and grunting, fixing on wall with nut bolts washers proper with PCC complete all as specified and directed.
SEWAGE DISPOSAL S&F for 75mm thick Steel Fibre Reinforced (SFRC) cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply, installation, testing and commissioning of submersible pump set electric driven 3 phase 415 volts 50 Hz, 18 stage having head not less than 216 meters of capacity 15 HP complete all as specified and directed. Make: KSB model no. CHORA CHROM 150-17/20 + UMAI 150-13/22or equivalent of Make Kirloskar/ Crompton Greaves. Material of Construction: Impeller: Stainless steel , Diffuser: Stainless steel , Diffuser casing: Stainless steel, Shaft; Stainless steel ,Bearing Sleeve : High Crome Stainless steel
Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer - in charge complete including submitting the strata details both graphically recorded as well as strata results complete all as specified and directed Note :- The rates quoted shall deemed to include to get survey done for availability/ facibility of water as recommended by geological water department Rajasthan before execution of work
Widening of trial bore upto 300 mm dia bore in aluvium soil / soft strata at any depth including all works pertaining to boring complete all as specified and directed.
All as per item No 21 above but of 200mm dia in hard rock and drilling with DTH system till meeting water strata all as directed.
All as per item No 21 above but of 200mm dia in hard rock and drilling with ODEX system till meeting water strata all as directed.
Supplying and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm dia of 5.4mm thickness (minimum ) upto required depth below ground level in all strata including cutting welding as required, painting etc complete ISI marked providing MS well cap complete all as specified and directed.
Supply, assembling, including jointing lowering and fixing in position ERW MS slotted pipe 200mm dia of 5.4 mm thickness (minimum) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting, welding as required and painting etc complete all as specified. Note for Sr Item No-24&25 :- Rate quoted by contractor shall deemed to include for S&F well cap 200 mm dia on top of pipe with locking arrengement till the bore well become functional complete.
Supply, assembling, including jointing lowering and fixing/holding in position for 50 mm bore GI medium grade column pipe in 6 m length with flanged joints, flanges pipe duly fitted with proper size GI Nut, bolts & rubber Gasket etc as required at site suspended in deep well complete with slotted clamps of required size at regular intervals for holding submersible cable complete all as specified and directed.
Supply and packing with Pea gravel of 8mm to 4.6mm size of approved quality as ordered to packed around the casing/slotted pipe in bore well complete all as specified and directed.
Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM complete all as specified and directed. Note:- (i) Yield test for the bore well by continuously pumping 16 hrs to determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted. (ii) Testing of water for portability, dissolved solids, physical/chemical and bactorogical testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions.
S&F housing clamp 90 cm long 7.5 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC (1:2:4) type B1 using 20 mm graded stone aggregate in block complete all as specified and directed.
M & L for strata sample box of second class hard wood (Hollock / Bijasal) of size 40cm x 30cm x 20 cm complete all as specified and directed.
Supply, installation, testing and commissioning of horizontal open well submersible pump set electric driven 3 phase 415 volts 50 Hz , having head not less than 50 meters of capacity 15 HP complete all as specified and directed. Make: KSB model no. MR 15 C-65-50-54SD or equivalent of Make:- Kirloskar/ Crompton Greaves.
S & F 1100 Volts grade submersible cable flate 3 core 10 sqmm with copper conductor stranded fixed to column pipes with suitable clamps jointing material complete.
EXTERNAL ELECTRIFICATION Supply and fix SMC street light control box of size 300 x 200 x105 mm including aluminium bus bar of adequate capacity and one no. MCB SP 16 Amps 230 volts including connecting up with the electrical connections and fixing and clamping complete and all as directed.
M&L for GI pipe bracket 40 mm bore single swan neck shape suitable to fix on top of tubular pole complete with nuts, bolts and washers complete all as specified and as directed.
Supply and installing testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box volts 3 phase and neutral suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Aluminium bus bar 315 Amp rating installed on porcelain insulators not less than 60cm long. The panel shall be dust and vermin proof, IP 54 class protection and made of 3.15 mm CRCA MS sheet and 40x406mm thick angle iron frame work, powder coated finish, front and rear opening type with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65m Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with the following accessories :- (Transformed to Main Panel)
Incoming (a) MCCB 250 Amp 36 KA rating 4 Pole 440 volts with magnetic setting and thermal release – 01 No. Multifunction meter class 1.0, three line Bakelite LCD display with back sealing arrangement, with meter run hour & power on hour, AVG, max & total value of active, reactive & apparent power & span shot of power (KW), current (I), Voltage (V) & PF with programmable CT Ratio of -/5A along with suitable size core CTs for current sensing (Make HPL Cat Part No. NEMFVIFPPE000 or equivalent in L&T/ Secure/ Conserve). (b) Indication lamp 22.5mm dia LED type 240 volts AC to show three phase availabiltity-01. Outgoing (a) MCCB 160 Amp 25 KA rating 4 Pole 440 volts with magnetic setting and thermal release – 01 No. (b) MCCB 100 Amp 25 KA rating 4 Pole 440 volts with magnetic setting and thermal release – 01 No. (c) MCCB 63 Amps 25 KA 4 Pole 440 volts fixed type -01 No (d) Time switch astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contractor fitted inside panel qty-1 Set
Supply and installing testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Aluminium bus bar 125 Amp rating installed on porcelain insulators not less than 60 cm long. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front and rear opening type with aprons for cable entry, with double door shutter and locking arrangement including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with the following accessories :- (Main LT Panel to JCOs Building)
Incoming (a) MCCB 63 Amp 16 KA rating 4 Pole 440 volts with magnetic setting and thermal release - 01 No (b) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.) (c) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set. (d) Aluminium bus bar three phase 125 Amp set of 4 Nos Outgoing (a) MCB TPN 40 Amps 16 KA rating 4 pole 440 volts fixed type -01 Nos (b) MCB TPN 32 Amps 16 KA rating 4 pole 440 volts fixed type -01 Nos.
Supply and installing testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Aluminium bus bar 200 Amp rating installed on porcelain insulators not less than 60 cm long. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front and rear opening type with aprons for cable entry, with double door shutter and locking arrangement including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with the following accessories :- (Main LT Panel to ORs Building)
Incoming (a) MCCB 160 Amp 25 KA rating 4 Pole 440 volts with megnatic setting and thermal release - 01 No (b) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.) (c) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set. (d) Aluminium bus bar three phase 200 Amp and neutral 100 Amp set of 4 Nos Outgoing (a) MCCB 63 Amps 16 KA rating 4 pole 440 volts fixed type -02 Nos
Supply and installing testing and commissioning factory made (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type plate form mounted suitable for 415 volts 3 phase and netural suitable for 4 wire 50 Hz AC supply system having bus bar chamber with insulated Aluminium bus bar 125 Amp rating installed on porcelain insulators not less than 60 cm long. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish, front and rear opening type with aprons for cable entry, with double door shutter and locking arrangement including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with suitable size of copper strip from bus bar to MCCB and metering wiring with PVC insulated, stranded copper conductor, FRLS Cable, IS-694 marked of adequate size but not less than 4 sqmm with the following accessories :- (Main LT Panel to Borewell Panel)
Incoming :- (a) MCCB 100 Amp 25 KA rating 4 Pole 440 volts with megnatic setting and thermal release - 01 No (b) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing (Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve.) (c) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set. Outgoing:- (a) Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 03 Nos Make-L&T/Havells/AE (b) Single phase preventor mini lec VSP-II-03 Nos Make-Havells/ABB/L&T/BCH/C&S (c) Phase sequance corrector 15 HP motor, 3 phase-01 No Make-Havells/ABB/L&T/BCH/C&S (d) Wiring with suitable size copper conductor cable not less than 6 sqmm PVC Sheathed copper conductor for LT panel. (e) MCB TPN 32 Amps 16 KA rating 4 pole 440 volts fixed type -03 Nos Note: Quoted rates shall be deemed to include for grouting / fixing of bus bar chamber in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge
Supply, install, testing & commissioning automatic power factor correction (APFC) panel 80 KVAR with metallised polypropylene capacitor bank MPP heavy duty of following capacity or nearest higher suitable to make step banking as per load requirement with minimum 12 steps (in the following combinations 10x5=50, 5x4=20, 3x2=6 & 2x2=4 KVAR) including intelligent relay controller having provision of multifunctional LCD display, set optimising control of capability 'with having facility of display system voltage, reactive power, active power apparent power apparent current total harmonic display VTHD, ITHD plus individual harmonic display of voltage and current temperature with alarm out put including alarm system and front panel programming including connection with PVC copper conductor cable of suitable size housed in powder coated PBI sheet housing with hinged door dust proof and connecting with main etc. all as directed with following components
(All components & capacitor bank shall be housed in enclosure factory made out of 16 SWG MS sheet outdoor in installation KIOSK type dust and vermin proof with suitable ventilating shutters (louvers) powder coated sheet metal feeder pillar box as per IS-5039 all as specified having locking arrangement , set of CTs Discharge reactors contactor heavy duty 4 pole 415 Volt with AC coil including MCBs indicating lamps and bypass system Alarm bell 240 volts 50 Hz -01 No. etc complete to achieve point 0.99/1.0 near to unity including necessary foundation pillar type copper bus bar not less than 60 cm long 400 Amp -04 Nos. including MCCB 4 Pole 200 Amps 25 KA -01 No. 50 Hz, 3 phase system complete all as specified and directed.
M&L for boring of existing road/path upto 100 mm bore for laying of GI pipe protection for UG cable including making good distrurbed area/surface all as specified and directed.
Supply and erecting cable route marker for HT Cable made of precast RCC (1:2:4) using 20mm graded stone aggregate cast in pillar of size 15x15x60cm including reinforcement with 4 nos 10mm dia defamed bars of 55 cm length and link/straps of 8mm dia bras at 150mm C/C and in fixing in ground level duly pained & written HT 11 KV including PCC & earth work
Supply and erecting cable route marker for LT Cable made of precast RCC (1:2:4) using 20mm graded stone aggregate cast in pillar of size 15x10x60cm including reinforcement with 4 nos 10mm dia defamed bars of 55 cm length and link/straps of 8mm dia bras at 150mm C/C and in fixing in ground level duly pained & written LT .433 KV including PCC & earth work
FENCING AND GATE M&L for Steel gate 5.45 m wide and 2.0 m high including RCC pillers (600X600mm) , double leaf including foundation guide rails, stoppers two coats of cement base paint to pillars and two coats of synthetic enamel paint over one coat of zinc chromate primer to steel surfaces including excavation & earth work in soft/disintegrated rocks etc, mass concrete 1:4:8 type D2, complete all as specified and shown on drawing no TD/2004/13 sheet no 1/3 to 3/3.
SUMMER APPLIANCES AND AIR CONDITIONING S&F wall mounted indoor voltage stabilizer automatic operation single phase and designed for input variation between 90 V to 300 Volts with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 1 KVA complete all as specified & directed. Make:- Make V-Guard, Model No. VEW 150 Plus or equivalent in Microtek, Luminous
Supply and installation of desert cooler of MS sheet minimum thickness 20 sheet gauge electric driven (230 volts, single phase, 50 Hz supply) having nominal air flow capacity of 5000 cum per hour or nearest higher standard size complete all as specified and directed including following accessories :- Note:- the rate of grass pad shall be included in the rate quoted by contractor.No Misunderstanding shall be entertained.
Supply and installed Refrigerator, electric driven (single phase) capacity upto 310 Ltr BEE 5-Star rated complete all as specified and directed.
Supply and installed Refrigerator, electric driven (single phase) capacity Upto 195 Ltr, BEE 5-Star rated complete all as specified and directed.
Supply, installation, testing & commissioning silent type diesel engine driven generating set of capacity 40 KVA at 0.8 PF, 3 Phase 4 wire 50 Hz, 415 Volt AC incl Digital Automatic Mains Failure Control Panel, water cooled mounted on common base frame complete with anti vibrating pad including foundation, fuel tank and other accessories, complete all as specified and directed as per the following parameters:-
(a) DIESEL DRIVEN ENGINE. Engine to develop required BHP to match with 40 KVA rated alternator at 1500 RPM including connecting, testing as per BIS-649 under NTP conditions with the following accessories. (i) ALTERNATOR. Alternator shall be of capacity 40 KVA net output at work site after commissioning, de-rating factor as per MSL, high and temperature condition as applicable at power factor 0.80, AC, 3 phase, 4 wire AVR system screen protection, ball/roller bearing with damp proof winding on each pole, factor as per IS-1722, complete all as specified and directed. (ii) DIESEL ENGINE. Diesel engine shall be vertical type of adequate capacity suitable for above alternator after considering all applicable de-rating factors for site condition as brought out in (a) as per relevant IS code having provision of coupling shaft to drive the above alternator independently after considering power losses in all the accessories forming part of the set i.e. coupling and type, FIP, water cooled directed injection, cold starting RPM 1500, industrial type with standard accessories, complete in all respect with following provisions:- (i) Fly wheel with housing with suitable flexible coupling. (ii) Radiator assembly complete with fan, water pump and thermostat. (iii) Dry type Air Cleaner as per latest CPCB norms. (iv) Fuel Injection Pump. (v) Governor Electronic/ Mechanical variable speed as per manufacturer's design. (vi) Flexible coupling with guard, nuts and bolts. (vii) Fuel Filter and Oil Filter with mounting. (viii) Lubrication Oil Pump.(ix) Self Starter. (x) Exhaust silencer residential type with wool/ hexagonal wire netting and aluminium sheet as per latest CPCB norms. (xi) Drip Dry. (xii) Instrument panel complete with starting switch and key lubricating oil pressure gauge, water temperature guage and push button, tachometer and hour meter. (xiii) Engine protection unit for low lubrication oil pressure and high coolant temperature. (xiv) Dynamo/Alternator.
(b) ALTERNATOR. The above engine should be coupled through flexible coupling to an indigenous alternator, mounted on strong steel fabricated common base frame suitable for mounting on a permanent foundation. The alternator will be 3 phase, 50 Hz 1500 RPM self regulating, self exciting type and will generate 40 KVA at 0.80 PF, 415 Volts, 4 wire AC supply under NTP conditions when running at 1500 RPM. The Alternator would be screen protected and fitted with end shields ball/ roller bearing and generally confirm to BS 2613/IS4772. (c) CONTROL PANEL. Cubical type, floor mounted on suitable size frame, made out of sheet metal steel of thickness not less than 1.60mm with front hinged cover for easy accessibility complete with necessary control circuit, fuses, bus bar of suitable size. The panel shall have the indicating instruments and switches and provisions and making incoming and outgoing electric connection. The control panel shall have suitable control for all parameters complete all as specified and directed. (d) FUEL TANK. One No of sheet metal steel tank of suitable capacity to hold diesel sufficient for 12 hours running at full load but in no case it shall be less than 100 Ltrs, mounted on angle iron frame including the following:- (i) Fuel level indicator to indicate level of diesel in the tank. (ii) Drain plug with 2 meter pipe of drain oil. (iii) Fuel Strainer.(iv) Hose Pipe for Fuel. (v) Air vent.(vi) Manually operated one No. fuel pump (For filling diesel in fuel tank). (vii) Battery 12 Volts - 01 No of suitable capacity as per manufactures recommendations with copper lead, terminals, fixed on wooden platform/base.(e) One No. base plate shall be MS fabricated and of rigidly welded constructions duly ribbed suitable for receiving engine, alternator, alongwith flexible coupling. It shall include set of bolts, washers, rubber coupling drip tray and protective screen around coupling.
(f) ACCOUSTIC ENCLOSURE FOR GEN SET. OEM supplied accoustic enclosures suitable for 40 KVA capacity diesel Generator sets duly fabricated of channel and CRCA sheet 1.60mm thick of required size having doors, sides and top insulation by mineral rock wool confirming to IS-8183 of adequate thickness, accoustic louvers/ outlet, ventilation system etc. complete as per latest CPCB norms with wiring and lighting arrangements. UV resistant powder coating applied all over the body, complete all as required at site and comprising of the following:- (i) BASE. Suitable size as per provided by the manufacturer/ CPCB norms. (ii) STRUCTURE. Suitable structure as provided by the OEM. (iii) DOORS. Suitable doors as provided by the OEM. (iv) OUTSIDE COVER. Suitable outside cover as provided by the OEM. (v) ACCOUSTIC INSULATION. As per latest CPCB norms. (vi) INSIDE COVER. Suitable inside cover as provided by the OEM. (vii) INSPECTION PORT. Acrylic sheet of suitable thickness with rubber gasket. (viii) ACCOUSTIC LOUVER/ATTENUATORS AT AIR INLET/OUTLET. This should provide excellent sound attenuation and good weather protection. Single blade and chevron blade louvers manufactured from 16 SWG CRCA sheet top section with and including fire proof accoustic infill as per latest CPCB norms The under section is formed from 18 SWG CRCA performed sheet after covering with fire resistant tissues to prevent fire migration or by means of accoustic lines ducts. (ix) CONSTRUCTIONS. Welded or bolted. (x) VENTILATION. As per latest CPCB norms. (xi) WIRING & LIGHTING. PVC copper wire concealed in flexible conduit provided with fluorescent tube light and MCB including the following:- (aa) Earthing panel (Neutral body) with GI strip (4 each). (ab) Control Panel. (ac) Cables leads for batteries. (ad) Power cable to equipment.
(xii) PAINTING. UV resistant powder coating as per manufacturer's specifications. (xiii) ACCOUSTIC LINES DUCT FOR VENTILATION. Accoustic line duct for ventilation to be provided made out of GI sheet.SAFETY FEATURES:- (aa) Lockable doors with angle key. (ab) Handles with in built locks. (ac) Emergency stop push button. (ad) Thermostat provided to cut off engine incase of high temp with in enclosures. NOTES :-(a) The complete generating set including engine/ alternator shall be factory assembled by manufacture or other authorised dealer as approved for assembling the DG set. (b) Generating set will be placed on suitable foundation as recommended by manufactured and cost there of shall be included on the prices quoted. (c) Generating set shall be supplied with following maintenance spares at no extra cost to the Govt: - (i) Fuel filter element - 02 Nos. (ii) Oil Filter Element - 01 No. (iii) Fan Belt - 01 Set. (iv) Hose pipe - 01 Set. (v) Tappet Cover gasket - 01 No. (vi) Tool kit as supplied by the OEM with gen set.
JYOTI ENTERPRISES
VEE SONS BUILDERS PVT LTD
Jasraj & Company
SOOD ASSOCIATES PVT LTD
M/S RAJINDER SINGH
BHARATSHAH CONSTRUCTION CO
Jasvit Constructions Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .