| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹21.1 L+₹1.7 L (8.81%)Rejected-Finance 6TH CROSS STREET KAMARAJ NAGAR PALAYAMKOTTAI | PALAYAMKOTTAI | TIRUNELVELI | TAMIL NADU | 627002 | L2 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
10 Nov 2022, 6:00 pmClosed
GE(South) Bangalore
GE(South) Bangalore
REPAIRS REPLACEMENT OF ROOF SHEET, ROOF TREATMENT, CHEJJA REPAIR AND OTHER CONNECTED WORKS INCLUDING REPAIRS TO PLINTH PROTECTION UNDER AGE B/R (CENTRAL) OF GE(SOUTH) BANGALORE
2022_MES_557627_1
8644/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
Yes
GE(South) Bangalore
₹40,000
Yes
18 Nov 2022
13 Oct 2022
12 Nov 2022
13 Oct 2022
10 Nov 2022
27 Oct 2022
Amount
Dismantling boarding, any description, fixed any position with nails.
M&L false ceiling horizontal level armstrong/daiken make regular edge grid 605X695mm using hot dip sections and tiles of fine and fissure 600X600X15mm suspended the grid with grid hangers/Rcc all as per mafrs instructions and directed.
S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm, complete all as specified.
Hangers 4 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified.
M&L 4 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work with screws
Dismantling asbestos cement (corrugated/semi corrugated etc) sheets in roof coverings
Dismantling rafter/timber unframed scantling 40 Sq cms and over in sections in any position
Ditto as item above but in fillet, rails, posts rafters, purlins etc under 40 sqcm in section, fixed in any position.
S&F mild steel rolled section of grade Fe 410 (Gde E-250) quality A as in main and cross beams hip and jack rafters; purlins where connected to common rafter and running rails ; and similar works fixed with and incl. angle cleats or other connecting plates all as directed by Engr-In -Charge.
S&F rolled mild steel section of grade Fe 410 (Gde E-250) quality A as in framed roof trusses, framed gate incl pintle hinges etc. and similar works fixed with and incl. angle cleats or other connecting plates all as directed by Engr-In -Charge.
M&L for preparing new or previously untreated surface of steel any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified
S & F 0.50 mm thick pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet of an having.colour on exterior side tensile strength of 550MPA as in roof covering/cladding to walls fied with self tapping screws as specied and conforming to all as specified and directed.
All as per item No. 12 above but plain sheet as in ridges
Removing Existing water proofing treatment, including bedding concrete etc complete, cleaning the surfaces with wire brushes, removing dust, foreign material ,scrubbing down with water and rubbish off the same beyond the Defence land.
Material and labour for PCC 1:2:4 type B0(using 12.5mm graded stone aggregate) for but on roof slab as required to fill up the undulations to maintain smooth slope (avg thickness 25 mm.)
Material and labour for rendering 15mm thick in CM 1:4 on roof surfaces mixed with WPC finished even and smooth without using extra cement. Note: WP compound will be measured and paid seperately.
Supply only integral water proofing compound.
Material and labour for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) for filleting and benching, slightly rounded or chamfered on edges.
M&L for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under: (a) Apply bitumen primer at the rate of 0.27 litre per Sqm as per IS 3384-1986 and bonding bitumen of VG-10 @1.20 Kg per Sqm. (b) APP modified water proofing memebrane as per IS 16540/16532-2017, 3mm thick and weighing not less than 3.50 kg per Sqm reinforce polyster/HMHDPE matt black finish over compatible primer/bonding bitumen and finish the top surface with bituminus aluminium paint @0.10 Ltr per Sqm complete all as specified.
S & F of CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of 20 mm dia GI pipe complete all as specified.
S&F of 25 mm dia CPVC brass elbow complete all as specified and as directed.
S&F of 25 mm dia CPVC Brass Tee complete all as specified and as directed.
S&F of 25 mm dia male brass threaded adapter complete all as specified and as directed.
S&F of 25 mm dia female brass threaded adapter complete all as specified and as directed.
S&F of 25 mm dia CPVC Union complete all as specified and as directed.
Disconnecting existing tanks of capacity exc 500 ltr and n.exc 1000 ltr tanks, setting aside (or lowering if required) for repairs, cleaning etc, and hoisting if required reconnecting and re-fixing in position complete all as specified
S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position including dismatling and removing to store all as specified
S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed including dismantling and removing to store in position all as specified
S&F 20 mm bore Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete, fixed in repairs, all as specified.
S&F 20 mm bore nipple suitable for HDPE water tank. (Min wt 45 gms).
Demolition cement concrete (Un reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level).
M&L PCC 1:3:6 type C-2 (using 40mm gde coarse agg) as in 100 mm thick hard standing surface is to be finished even & fair whith out using extra cement including brooming down whilst concrete is in green.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces as in Chajjas, balcony roof drop etc in cement mortar 1:4 incl finished even and smooth including taking down all as specified and all as directed
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer surface
S&F 110 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed inwalls or in floors complete all as specified & directed by Engineer-in-Charge.
S& F in repair PVC bends any radius 110mm dia complete all as specified & directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) bends any radius with access door
PVC 110 mm bore (SWR), junction single, (Single T) equal or unequal with access door
PVC 110 mm bore (SWR), junction double, (double T), equal or unequal with access door.
PVC 110 mm bore (SWR) couplers
Removal of vegetation/tree growth etc on external surface of walls or on roof top in two/four storey building by taking all necessary precaution to the workers and also the adjacent govt properties including digging out of filling holes with PCC 1:2:4 type B1 using (20 mm graded stone aggregate) and finishing the surface to match adjacent surfaces after application of suitable chemical using " break" manufactured by M/S denocil company or equivalent to avoid re growth of the vegetation and removing the debris to outside the MD land complete all as specified and directed(Any damage to the adjacent govt properties like glass windows , pipes lines etc to be made good without any extra cost. (a) For plants girth not exc 5 cm
All as above item No 41 for plants girth exc 5 cm and n.exc 15 cm
M/S POTHIRAJ AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .