Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹8.0 L+₹55,655 (7.43%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Being not lowest |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
10 Apr 2023, 6:00 pmClosed
Shri Pranav, AGE (I)
AGE (I) Manauri Prayagraj-212212
REPAIR/MAINT OF SPLIT AC, WINDOW AC, WATER COOLER, REFRIGERATOR, DEEP FREEZER AND CONNECTED ITEMS AT AF STN MANAURI
2023_MES_584880_1
9058/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹17,800
Yes
3 May 2023
7 Mar 2023
12 Apr 2023
7 Mar 2023
10 Apr 2023
22 Mar 2023
Amount
M&L for Servicing, overhauling and testing of split type/window type AC, capacity 1.5 ton/2.00 Ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as specified and directed. Note: Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back shall deemed to be inclusive in the unit rates quoted by the contractor against this item.
S&F in replacement new compressor for window/ split type AC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and branded) complete all as specified and directed. Make: Kirloskar / Voltas / Carrier / Whirlpool / Bluestar Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge.
S&F in replacement new compressor for window/ split type AC 2.00 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and branded) complete all as specified and directed. Make: Kirloskar / Voltas / Carrier / Whirlpool / Bluestar Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge.
M&L for trickle charging of gas R-22/R-32/R-134/R-407 as required in AC of capacity 1.5 ton, after detection of leakage with soap solution/halide torch, making the system leak proof by brazing / soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed.
S&F copper capillary tube (suction tube) of 1st quality copper size 1/2" and 3/8" or 5/8" duly complete with insulation suitable for split AC cap upto 2.00 TR including taking down old unserviceable copper tube complete all as specified and directed.
S&F copper tube (liquid tube) outer dia as per existing size complete with insulation suitable for split Air conditioner cap upto 2.00 TR including taking down old unserviceable copper tube complete all as specified and directed.
M&L for disconnecting of existing split air conditioner capacity up to 2.00 Ton, shiftting and reinstallation, in same location or another location including factory made GI brackets out door mounting unit with nut bolt washer etc complete all as specified and directed.
S&F nylon type filter pad 20 micron for window type AC of capacity up to 2 ton including taking out old unserviceable filter pad complete all as specified and directed.
S&F nylon type filter pad 20 micron for Split type AC of capacity up to 2 ton including taking out old unserviceable filter pad complete all as specified and directed.
S&F in replacement running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F capacitor 50/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unserviceable capacitor complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F capacitor 60/6 MFD, 440 volts clip type suitable for window/split air conditioner 2.00 Ton clip type complete including taking down old unserviceable capacitor complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F capacitor 36/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unserviceable capacitor complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F capacitor 45/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unserviceable capacitor complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F in replacement starting relay suitable for window type AC of capacity up to 2 ton compete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F in replacement thermostat switch of working temp 6 degree to 20 degree suitable for window type AC or split type of capacity up to 2 ton complete all as specified and directed.
S&F in replacement starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F in replacement blower motor 1/8 HP, double shaft, single phase suitable for split type Air conditioner capacity up to 2 ton including testing complete all as specified and directed. Make: Whirpool / LG / Khaitan
S&F condensor fan motor single phase electric motor, 230V, 50 Hz, 1050 RPM, 60 watt fitted with ball bearing suitable for split type Air conditioner capacity up to 2 ton including testing complete including taking down old unserviceable condensor fan motor complete all as specified and directed. Make: Whirpool / LG / Khaitan
S&F in replacement fan blade for blower motor for window type AC capacity up to 2 ton complete all as specified and directed. Make: Whirpool / LG / Khaitan
S&F in replacement fan blade for condensor motor for split type AC capacity up to 2 ton complete all as specified and directed. Make: Whirpool / LG / Khaitan
S&F condensor copper coil unit of Split Air conditioner capacity up to 2.00 Ton including taking down old unserviceable condensor coil unit complete all as directed.
S&F in replacement MS factory made stand powder coated (as per sample) including zebra bolts & washers complete all as specified and directed.
S&F single pole and neutral enclosure (MODULAR AC BOX) 4 module in sheet steel with a two pin and earth plug and socket with one single pole MCB 25 Amp 10 KA including taking down old unserviceable AC box complete all as specified and directed. Make: STANDARD Cat part No DSDPUSN020 / Indoasian / Schneider / Siemens / Legrand
S&F MCB single pole and neutral (SPN) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable MCB complete all as specified and directed.
M&L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through concealed PVC conduit complete including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire by cutting chases in walls by cutter and making good the surface in CM 1:3 including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 6.00 Sqmm multi stranded copper cable and one run of 6.00 Sqmm earth wire and PVC conduit 20 mm shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the PVC conduit.
S&F PVC copper conductor cable of size 4 Sqmm 3 core PVC sheathed suitable for supply for outdoor unit and indoor unit complete with taking down old unserviceable cable complete all as specified and directed.
Supply, installation, testing and commissioning of outdoor units suitable for split type AC 1.5 TR (1500 watts) cooling capacity 5275 watts 5 star rated dual invertor single phase 230 volts 50 Hzs in origional with intallation copper pipe in standard size, compressor, initially gas charging R-22, condensor motor, condensor coil, factory made GI mounting stand with nut, bolt & washers etc including taking down old unserviceable outdoor unit complete all as specified and directed. Make: Make:- LG/ Hitachi / Voltas/Samsung/Blue star. Note: Unserviceable outdoor unit shall be deposited to MES store yard.
Supply, installation, testing and commissioning of air condition indoor units capacity 1.5 TR input voltage 1500 Watt and cooling capacity 5275 W split type suitable for 5 star rated out door unit in original with indoor blower motor, PCB, cooling coil, etc accessories including taking down old unserviceable indoor unit complete all as specified and directed. Make: LG/Hitachi / Voltas/Samsung/Blue star Note: Unserviceable indoor unit shall be deposited to MES store yard.
S&F power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed including taking down old unserviceable PCB complete all as specified and directed.
Attending complaints and rectification of defects of any type AC, Refrigerator, Desert cooler, Water Cooler, Deep Freezer, Voltage Stabilizer etc and testing complete all as specified and directed. Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M and recorded in the register maintained for the purpose. (ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc shall deemed to be included in the unit rate quoted by the contractor against this item.
S&F including testing new compressor for water cooler of capacity 40/80 Ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make: Kirloskar Model 2612 / Shriram Model-412Y / / Carrier / Whirlpool / Bluestar
S&F including testing new compressor for water cooler of capacity 60/120 Ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make: Kirloskar / Voltas / Carrier / Whirlpool / Bluestar
S&F in replacement blower motor 1/35 HP with base and clamp, rubber mountings for water coolers including taking out the old unserviceable motor complete all as specified and directed.
S&F including testing blower motor suitable for Deep freezer hard top 200 ltrs capacity having single door any make including taking down unserviceable blower motor complete all as specified and directed.
M&L for trickle charging of gas F-12 or as required in water cooler, any capacity, after detection of leakage with soap solution/halide torch, making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed.
S&F in replacement push type water tap, 15 mm dia, chromium plated suitable for water cooler complete all as specified and directed.
S&F in replacement thermostat switch suitable for water cooler any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of Water Coolers including scraping down smoke soot, moulds, moss, salts etc, removing oily & greasy material and applying two coats of synthetic enamel paint of first quality using ‘spray machine’ over one coat of primer including marking of SM/MES Srl No in block letters with black paint complete all as specified and directed.
S&F including testing new compressor for refrigerator of capacity 286/310 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof including taking down unserviceable compressor complete all as specified and directed. Make: Kirloskar / Voltas / Carrier / Whirlpool / Bluestar
M&L for trickle charging of gas F-12 or as required in refrigerator of capacity 286/310 Ltr, after detection of leakage with soap solution/halide torch, making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed.
S&F in replacement freezer assembly suitable for refrigerators of any make, 286/310 ltrs capacity including taking out old unserviceable assembly complete all as specified and directed. Make: Kelvinator / Zenith / Godrej / Whirlpool / Voltas
S&F in replacement door panel (AB plastic), suitable for refrigerators of any make, 286/310 litres capacity including taking out unserviceable door panel complete all as specified and directed. Make: Kelvinator / Zenith / Godrej / Whirlpool /Voltas
S&F in replacement starting relay for refrigerator of different capacity/make including taking out unserviceable relay complete all as specified and directed.
S&F in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified and directed.
S&F in replacement capillary tube made of copper any size suitable for Refrigerator/Water Cooler including taking out old unserviceable capillary tube complete all as specified and directed.
S&F in replacement capillary filter drier 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified and directed
M&L for servicing & overhauling of desert cooler, any size/type/make including greasing, oiling of fan motor and vertical Pump (Tulu Pump) decarbonising the electric connections, reconnecting cable connection by providing new thimbles, duly PVC insulated the joints as per requirement complete all as specified and directed.
M&L for painting desert cooler of capacity 5000 Cu M/hr with spray painting machine with two coats of synthetic enamel paint powder coated (first quality, shade: silver grey as approved by Engr-in-Charge) and two paint to inner surfaces including preparation of surface and painting inside with black rubber bitumen paints complete all as specified and directed. Make: ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson Paints (BOROLAC) Berger paints (LUXOL HI CLOSS )
S&F in replacement blower motor copper wound 200 watt, 1/8 HP, single phase suitable for desert cooler including testing complete all as specified and directed. Make: Khaitan / Crompton / Bajaj
M&L for taking down existing unserviceable fan motor from desert cooler with and including replacement of wornout winding, bushes and bearing etc and testing, refixing and connecting complete all as specified and directed.
S&F vertical pump (Fish type) for desert cooler, single phase 230 Volts including taking out unserviceable vertical pump complete all as specified and directed. Make : Khaitan / Crompton / Bajaj
S&F Water lifting submersible pump suitable for desert cooler as per existing capacity including taking down old unserviceable pump complete all as specified and directed.
S&F PVC distributor Tee or elbow of size 15mm for desert coolers including taking out unserviceable distributor complete all as specified and directed.
S&F PVC pipe 15mm dia suitable for desert coolers including taking out unserviceable PVC pipe complete all as specified and directed.
S&F cooler pad made out of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed.
S&F starting capacitor 4 MFD 230 volts including taking out unserviceable capacitor, including testing complete all as specified and directed. Make: ABB / L&T / GE / EPCOS / HAVELLS
S&F shutters made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/ hour including taking out unserviceable shutters complete all as specified and directed.
S&F bottom tank made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable bottom tank complete all as specified and directed.
S&F top cover made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable top cover complete all as specified and directed.
S&F side support made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable side supports complete all as specified and directed.
M&L for replacement of Fan blade aluminium type of desert cooler heavy duty HDPE suitable for 4000/5000 CFM cap complete all as specified and directed.
S&F PVC copper conductor cable of size 1.00 Sqmm 3 core PVC sheathed suitable not less than 3 mtrs long with plug top 5 Amp suitable for desert cooler including taking down old unserviceable cable complete all as specified and directed. Make:- FINOLEX / POLYCAB / RR Cable / Grandlay
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
M/S vibhuti enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .