Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | ₹34.2 L Quoted ₹34.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹35.4 L+₹47,818 (1.37%)Rejected-Finance | ₹35.4 L+₹47,818 (1.37%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹36.2 L+₹1.3 L (3.66%)Rejected-Finance | ₹36.2 L+₹1.3 L (3.66%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹37.0 L+₹2.2 L (6.19%)Rejected-Finance | ₹37.0 L+₹2.2 L (6.19%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹37.3 L+₹2.4 L (6.88%)Rejected-Finance | ₹37.3 L+₹2.4 L (6.88%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
22 Jun 2024, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
REPAIR / MAINT OF INTERNAL ELECTRIFICATION BUILDING, SUB MAIN WIRING, SECURITY LIGHT AND ALLIED WORKS AT ALG TUTING AND MECHUKA UNDER GE (AF) JORHAT
2024_MES_657201_1
8639/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹70,000
Yes
31 Aug 2024
1 Jun 2024
24 Jun 2024
1 Jun 2024
22 Jun 2024
17 Jun 2024
Amount
Taking down carefully point wiring (light, fan, socket, etc.) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, sockets, etc. and making good to disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring with 1.5 sq.mm of FRLS grade PVC insulated and unsheathed stranded copper conductor cable, 1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20mm wide) complete with all acessories including PVC board/box of suitable size for mounting of switches, sockets, regulators, etc. including 1.5 sq.mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as earth continuity conductor for one light point controlled by one way switch complete by maintaining the colour code complete all as specified and directed.
All as per Serial item No. 2 here-in-before but for one ceiling / exhaust fan point controlled by one, one way switch.
All as per Serial item No. 2 here-in-before but for 5 amps socket point on independent board.
All as per Serial item No. 2 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board, using 2.5 sq.mm earth continuity conductor.
All as per Serial item No. 2 here-in-before but with 4 sq.mm cable for 20/25 amps power unit on independent board, using 4 sq.mm earth continuity conductor.
S&F as in repairs ceiling rose, surface backelite three terminals, PVC / polycarbonate insulated body complete all as specified and as directed.
S&F as in repairs switch piano, flush type, 6 Amps 240 volts, single pole, one way complete all as specified and as directed.
S&F as in repairs socket outlet, 5 pin, 6 Amps, flush type complete all as specified and as directed.
S&F as in repairs socket outlet, 15/16 Amps, 6-in-1, flush type complete all as specified and as directed.
S&F as in repairs switch piano, flush type, 15/16 Amps, 240 volts single pole one way complete all as specified and as directed.
S&F as in repairs fan regulator, electronic type, rotary step, socket type 240 volts complete all as specified and as directed.
S&F as in repairs switch socket combination, 2-in-1, 3 pin, 5 and 15 Amps, flush type universal with box complete all as specified and as directed.
S&F as in repairs switch socket combination, 2-in-1, 5 Amps, flush type with box complete all as specified and as directed.
S&F as in repairs switch piano, modular type, 6 Amps 240 volts, single pole, one way complete all as specified and as directed.
S&F as in repairs socket outlet, 5 pin 6 Amps, modular type complete all as specified and as directed.
S&F as in repairs socket outlet, 6/16 Amps, 6-in-1, modular type complete all as specified and as directed.
S&F as in repairs switch piano, modular type, 15/16 Amps, 240 volts, single pole one way complete all as specified and as directed.
S&F as in repairs modular plates with frame (white colour) 3 module complete all as specified and as directed.
S&F as in repairs modular plates with frame (white colour) 8 module complete all as specified and as directed.
S&F as in repairs stepped type electronic fan regulator, 2 modular type, 240 volt complete all as specified and as directed.
S&F as in repairs 20 watt integrated LED tube light fitting 4 feet, suitable for single phase, 230 volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrical connection with copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed.
S&F as in repairs round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, with LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size complete all as specified and as directed.
S&F as in repairs LED flood light 70 watt, 230 volt AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. MAKE : Philips, Cat No. 919515812818 or equivalent model of make as mentioned in Particular Specification.
S&F as in repairs post top lantern LED type 20 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with driver and lamp complete all as specified and as directed.
M&L for MCCB 4 pole, 415 volt, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for MCCB 4 pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
M&L for submain wiring with two runs of single core 6 sq.mm FRLS PVC insulated copper cable, 1100 volts grade, multistrand, unsheathed conductor drawn through PVC casing and capping (suitable size) and all necessary fittings including 1x6 sq.mm multistranded FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete all as specified and as directed. Note : Extra length of cables / wire as required for connection to MCBs / DBs shall not be measured under this items.
Taking down MCB DB/main switch of any size and making good to disturbed surfaces of wall/floor, etc. complete all as specified and as directed.
S&F as in repairs SP&N DBs, double door, 240 volt, 8 way complete all as specified and as directed.
S&F as in repairs SP&N DBs, double door, 240 volt, 4 way complete all as specified and as directed.
S&F as in repairs TP&N DBs, double door, 240 volt, 4 way complete all as specified and as directed.
S&F as in repair 415 volts, 10 KA, 'C' curve of TPN 40 to 100 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed.
S&F as in repairs miniature circuit breaker (MCB), TP, 415 volts, 10 KA, 'C' curve, 25 to 63 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed.
S&F as in repairs MCB single pole, 240 volts, 6 to 32 Amps, 10 KA, 'C' curve complete all as specified and as directed.
S&F as in repairs MCB single pole & neutral, 240 volts, 32 Amps, 'C' curve complete all as specified and as directed.
S&F in repairs surface mounted LED 2 feet x 2 feet luminaire of capacity 36 watts with white powder coated CRCA housing with LEDs and full window acrylic diffuser, etc.complete with all acessories internally prewired suitable for sigle phase 230 volts 50 Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed.
S&F in repairs for building security light 35 watt LED light fitting 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65 protection complete all as specified and as directed.
Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc. and keep in safe custody for re-use complete all as specified and as directed. Note: Necessary excavation and earth work shall be measured and paid for separately.
S&F XLPE insulated aluminium conductor, armoured, heavy duty electric cable, 1100 volts grade, 3.5 core, cross-sectional area 50 sq.mm complete all as specified and as directed.
Supply and laying un-reinforced pre-cast concrete cable cover, class LV, Type 2, flat, size 300mmx180mmx 40mm complete all as specified and as directed.
Excavating in trenches not exc. 1.50m wide and not exc. 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point in soft/loose soil complete all as specified and as directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (8cm in depth before laying the cable and 15cm in depth after laying the cable)) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F as in repairs MCB protected POWER UNIT with one 20/25 Amps socket, (including 3 pin plug top) including MCB SP/DP and starter 20/25 Amps, 220 volt rating with six module plate and flush metal GI box and electrically connecting up complete all as specified and as directed.
S&F triple pole and neutral sheet metal enclosure with a three pin and earth plug with socket of 32 amps complete with one triple pole MCB of 32 amps 415 volts complete all as specified and as directed.
S&F as in repairs for PVC insulated three core 2.5 sq.mm, multistrand copper conductor for connection of garden/bldg security light complete all as specified and as directed.
S&Fcapacitor 2.5 MFD, 440 volts AC 50 Hz suitable for ceiling fan of any sweep and make complete all as specified and as directed.
M&L for taking down and cleaning/descaling of Geyser of capacity 25/35/50 litres of any make with chemical solution, checking, tighting all electrical connections, tighting of all nut, bolts, etc. complete all as specified and as directed.
S&F as in replacement gasket for Geyser of any capacity complete all as specified and as directed.
S&F as in repairs Geyser heating element triangle/ as per sample 1.5/2.0 KW complete all as specified and as directed.
S&F as in repairs bimetal thermostat suitable for Geyser 25/35/50 litres of capacity complete all as specified and as directed. .
S&F as in repairs hot and cold flexible water connection stainless steel tube of 600mm long suitable for geyser complete all as specified and as directed.
S&F as in repairs for 12 watts cool day light emergency LED bulb rechargeable type with backup of 4 Hrs, CDL complete all as specified and as directed. NOTE:- The contract sum shall be derived by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ.
AJOY DUTTA CHOWDHURY AND CO
Chief Builders &Consultants
SUBHAS CONSTRUCTIONS
A K DUTTA CHOWDHURY AND CO
M/S DHAR AND DHAR
A M CHOUDHURY AND CO
M/S PAUL CONSTRUCTION
Bidder Name
A K DUTTA CHOWDHURY AND CO
A M CHOUDHURY AND CO
AJOY DUTTA CHOWDHURY AND CO
PEE BEE INDIA
M/S DHAR AND DHAR
M/S PAUL CONSTRUCTION
Chief Builders &Consultants
SUBHAS CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .