| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC FIRST FLOOR GEETA COMPLEX ROHTAK ROHTAK ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | ₹9.0 L | L1 | Accepted-AOC accepted |
| 2 | L2₹9.7 LRejected-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹9.7 L | L2 | Rejected-AOC rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical rejected |
| Sl No | Description | Qty | Unit | Netromics Engineering Solutions Private Limited L2 | Arora Telecommunication L1 |
|---|---|---|---|---|---|
| 1.00HSR Items | |||||
| 1.01 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] | 600 | P.Metre | 40 ₹24,000 | 36 ₹21,600 |
| 2.00 | [23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate] | 150 | P.Kg. | 120 ₹18,000 | 100 ₹15,000 |
| 3.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 150 | P.Metre | 32 ₹4,800 | 36 ₹5,400 |
| 4.00 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] | 15 | Each | 110 ₹1,650 | 100 ₹1,500 |
| 5.00NS Items | |||||
| 5.01 | Supply and Erection of MK channel of size 50 mm * 75 mm heavy duty with all accessoires and material required to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make : Blue Bird / Microtek / V- Guard | 35 | P.Metre | 430 ₹15,050 | 400 ₹14,000 |
| 6.00 | Supply and Erection of suitable size of white powder coated metal AC Stand for Split AC complete in all respect upto enitre satisfaction of Engineer-in charge of the work | 4 | Each | 1,000 ₹4,000 | 800 ₹3,200 |
| 7.00 | Supply, Installation, Testing and Commissioning of UTP Cat-6 information outlet RJ45 connector for face plate complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work. Make:- D-Link/AMP/Schneider | 50 | Each | 260 ₹13,000 | 200 ₹10,000 |
| 8.00 | Supply / Erection / Testing and Commissioning of MDF/ IDF with Krone make box duly painted and having lock facility including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. (i) 20 Pair | 1 | Each | 1,000 ₹1,000 | 800 ₹800 |
Tender Value
₹8.6 L
EMD Value
₹17,180
Closing Date
30 Dec 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
The provision of 1.8/2.0 Ton non invertor, ACs, 5 KVA Stabliser, LAN and EPABX system alongwith other allied accessories etc. has been made in this estimate
2025_HRY_492441_1
20258AE303C7 075C 4C7E AE8B A8A18C4AD743667BAR
Open Tender
Electrical Works
30 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹17,180
Yes
3 Feb 2026
23 Dec 2025
31 Dec 2025
23 Dec 2025
30 Dec 2025
23 Dec 2025
Amount
HSR Items
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
NS Items
Supply and Erection of MK channel of size 50 mm * 75 mm heavy duty with all accessoires and material required to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make : Blue Bird / Microtek / V- Guard
Supply and Erection of suitable size of white powder coated metal AC Stand for Split AC complete in all respect upto enitre satisfaction of Engineer-in charge of the work
Supply, Installation, Testing and Commissioning of UTP Cat-6 information outlet RJ45 connector for face plate complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work. Make:- D-Link/AMP/Schneider
Supply / Erection / Testing and Commissioning of MDF/ IDF with Krone make box duly painted and having lock facility including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. (i) 20 Pair
Supply and laying of Multicore Telephone Cable Conductor size 0.51 mm bright annealed Copper Conductor PVC insulated and shealed in existing pipe / Channel etc, including making necessary connection complete in all respect insulated and shealed in existing pipe / Channel and making necessary connection complete in all respect jupto the entire satisfaction of Engineer-in-charge of the work. (i) 2 Pair Telephone Wire, Make: - RR/ Grandlay / Finolex / Havells/ Polycab
Supply and laying of Multicore Telephone Cable Conductor size 0.51 mm bright annealed Copper Conductor PVC insulated and shealed in existing pipe / Channel etc, including making necessary connection complete in all respect insulated and shealed in existing pipe / Channel and making necessary connection complete in all respect jupto the entire satisfaction of Engineer-in-charge of the work. (i) 10 pair Telephone wire, Make: - RR/ Grandlay / Finolex / Havells/ Polycab
Supply and Installation of Operator-cum maintenance console with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward,Waiting,Transfer,Hold,Conference,Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself complete in all respect jupto the entire satisfaction of Engineer-in-charge of the work. Make: - Alcatel /Matrix / Cisco
Supply, Installation, Testing and Commissioning of 24 x 10/100/ 1000BASE-T, 4 x 100/1000 Mbps GbE/SFP combo ports, Full/Half-duplex for 10/100 Mbps, Full-duplex for 1000 Mbps, Media Interface Exchange Auto MDI/MDIX adjustment for all twisted-pair ports, Switching Capacity 56 Gbps, Transmission Method Store-and-forward, MAC Address Table 8K entries, Static MAC Addresses 256 entries, Packet Buffer Memory 4.1 Mbits, Maximum 64 Byte Packet Forwarding Rate 41.7 Mpps, CPU Memory DDR3 128 MB, Flash Memory 32 MB, Power Input 100 to 240 V AC 50/60 Hz internal universal power supply, Operating Temperature -5 to 50°C, Access Control Lists (ACLs), Port Security supports up to 64 MAC addresses per port, ARP Spoofing Prevention, Smart Binding, Static routing, Auto IGMP, Surveillance Mode, Auto Voice VLAN, Dual software images, Dual configuration files Make:Cisco/Juniper/Extreme/D-Link
Supply and Installation of Matrix Extension Card for existing EPABX System with 20nos. Single line telephone connection complete in all respect upto the entire satisfaction of Engineer-in-charge of the work.
Supply and Installation of Matrix Licence to add additional Extension Cards into the existing EPABX System complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. Make: - Alcatel /Matrix
Supply and Installation of Matrix 8 Port Digital Extension Card for existing EPABX System complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. Make: - Alcatel /Matrix
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge.Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc (i) 2 KVA UPS Make: Microtek/ APC/Liebert/Emerson
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with `U`Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL and RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. (i) 15 U rack Make: Comrack/Valrack/Hive network (HN)
Supplying, Installation, Testing and Commissioning of Analog phones having standard feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. Make:- Beetel / Panasonic / Matrix
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. (i) Copper Patch Cords of length 1m (3ft) Make: AMP/Molex/RandM/D-Link
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. (i) Copper Patch Cords of length 3m (10ft) Make: AMP/Molex/RandM/D-Link
Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make: AMP/Molex/RandM/D-Link
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 274 DELHI SCHEDULE OF RATES (EandM)-2025 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA- 568.2-D etc. to complete in all respect upto enitre satisfaction of Engineer-in charge of the work. Make: AMP/Molex/RandM/D-Link
Supply, Installation, Testing and Commissioning of Telephone in/out box with connector complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work. Make:- D-Link/AMP/Schneider.
Supply and Erection of 1.8/2.0 Ton 3 star of above Split type Air Conditioners (Non Inverter), Cooling Capacity 7050 W, Power supply 230V/ Single Phase/50 Hz, rated ISEER 3.81 KWH/KWH, White colour, Moisture removal 1.92 l/h, Indoor air flow distance 15 Mtr or above, Indoor noise level 44 dB (A), ambientoperating temprature range 18 degree C to 52 degree C, Evaporator and condensor coil is of copper material,Hyper tropical Rotary Compressor, Refrigerant Gas R32 with 1 Year Comprehensive warranty on machine andCompressor Warranty 5 years from OEM and including all the petty material as supplied by the manufacturersuch as three meter copper pipe and copper power cable etc. required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. Make: O General/ Hitachi/ Daikin
Supply and Erection of 5 KVA automatic voltage stablizer with voltage 150 V to 280, Copper Wound Suitable for air conditioners with 15 Amp. 3 pin plug top (White) as required complete in all respect upto enitre satisfaction of Engineer-in charge of the work Make: Blue Bird/ Microtek/ V-Guard
Netromics Engineering Solutions Private Limited (BID ID -1397177)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_570771.xls
BOQ • 0.30 MB
AD0145405.pdf
Additional Documents • 2.46 MB
OT0145405.pdf
Other Document • 0.79 MB
Download all tender documents and submit your bid