Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹49.1 L+₹59,535.62 (1.23%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L2 | Rejected-Finance other thgan lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
20 Dec 2019, 6:00 pmClosed
GE WEST LUCKNOW
11 sardar Patel marg lucknow cantt-02
SPECIAL REPAIR TO SEWAGE DISPOSAL, REWIRING IN PCDA OFFICE COMPLEX, WINDOW AT BLOCK C AND ROOF TREATMENT AT VIVEK VIHAR COLONY AREA OF AGE BR II UNDER GE WEST LUCKNOW
2019_MES_298796_1
GE/W/LKO/43 OF 2019-2020
Open Tender
Civil Works
Item Rate
180 days
Lucknow
Class D cat a i
8 documents required · 8 mandatory
₹500
Yes
GE WEST LUCKNOW
₹98,000
Yes
15 Jan 2020
18 Nov 2019
21 Dec 2019
18 Nov 2019
20 Dec 2019
2 Dec 2019
18 Nov 2019 - 28 Nov 2019
Amount
Taking down existing water proofing treatment of any description from roof surfaces and removing rubbish to a distance exc. 250m, complete all as specified and directed.
S&F in repair 20 mm bore steel water tubes "medium grade" galvanized with all fittigs such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as specified and directed.
S&F in repair 25 mm bore steel water tubes "medium grade" galvanized with all fittigs such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in padding on roof surface for correcting/ making proper slope on roof, surface finished fair and even without using extra cement complete all as specified and directed.(Note- water proofing compound mix with this pcc as per direction of E-in -Charge and paid seperately under revelant Item)
M&L PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in roof kerbs /benching or mud stops, rounded,chamfered on edges including necessary use and waste of from work etc all as specified and directed. (Note-water proofing compound mix with this pcc as per direction of E-in -Charge and paid seperately under revelant Item)
Supply only Liquid water proofing compound of approved make all as directed by E-in Charge.
M& L for Provn of roof treatment with AAP Polymeric water proofing membrane with BRICK TILES as under mentioned specifications:- (a) M&L Plastering 10 mm thick in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (b) Applying one coat of bitumen primer confirming to IS 3384 @0.50 Kg/sqm and allow to dry.© Applying one coat of hot blown bitumen grade 85/25 @ 1.20 kg/sqm over bitumen primer. (d) Applying and Lying 4 mm thick APP Membrane having Non-woven Polyester Matt at core and covered with High quality polymeric asphaltic protected with thermo fusible HMHDPE film on both sides and over laps 10 cm .and sealed by flame.(e) Applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 kg/sqm over bitumen primer.(f) Binding with coarse sand dry @ 0.50 to 1 Kg/Sqmts dustedover bitumen.(g) Screeding bed 15mm thick in CM 1:4 as bedding layer using 100% coarse sand . (h) S & F 40mm thick brick tiles jointed and pointed in CM 1:4 mixed with linseed oil @ 5% by weight of cement complete all as specified and directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame) n.exc 1.50 Sqm and removing from site as directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame)exc 1.50 Sqm and n.exc.4.00 sqm and removing from site as directed.
Demolition of brickwork or stone/boulder masonry, built in lime cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brick work with subclass ‘B’ bricks fly ash brick old size, straight or curved on plan exc 6m mean radius, built in cement mortar1:6 complete all as specified and directed
M&L for rendering 15mm thick on any face of brick walls or concrete surfaces in cement mortar 1:6 finished fair and even and including taking down cement plaster on brick wall including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed at site.
S&F for coloured glazed ceramic tiles 450 x300x 7 to 8mm thick and jointed in neat cement slurry and pointed with white/colour cement to match with the existing wall or vertical surface laid over & including 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and including dismantling of old floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store yard and rubbish off the primises complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coat of distempering oil emulsion, white or tinted over a coat of chalk whiting, on plastered surfaces,prepartory to distempering complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coat of cement base paint over a coat of cement wash complete all as specified and directed.
S&F aluminium glazed windows with frame partly fixed and partly openable from sides consisting of 5mm th frosted glass section weighing 0.55 Kg per RM incl necessary jointing cleats, glazing clips , rubber packing anodised snap beading screws aluminium anodised filling such as pag stayes 150mm long (01 No, hinges type B-21 100 mm long (02 Nos) handle (01) No of size 100mm and inclcluding fixing of stainless steel wiremesh in aluminium beadings all as specified and directed at site.
Demolition of PCC in ground floor and paving n.exc 15cm thick and below or above ground level complete all as specified.
Dismantling of floor hearth and wall tiling incl cement mortar backing coat complete all as directed at site.
Material and labour for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in cm 1:4 complete all as specified and directed.
Material and labour for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in cm 1:4 complete all as specified and directed.
S & F in repairs vitreous china wash down water closet (pedestal pattern) pan coloured with “P” or “S” trap including connection to drain or outgoing and to syphonage pipe completecomplete all as specified and directed.
M&L Brickwork with sub class B bricks, straight or curved on plan exc 6m mean radius, built in in CM 1:6 complete all as directed.
M&L 15 mm thick rendering in CM (1:6 ) on fair faces of brick wall or concrete surfaces finished fair and even all as specified.
M&L for 15mm thick rendering on brick work in CM 1:4 including using integral water proofing compound finished even and smooth without using extra cement complete complete all as specified and directed.NOTE-WPC shall be measured & paid separetly
M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggrtegate as in plinth protection including finsihing even & fair all as specified.
M & L PCC 1:4:8 type D2 as in fdn concrete using 40mm graded stone aggregate complete all as specified and directed
M&L 100 mm thick PCC 1:5:10 type E2 using 40 mm graded agg as in floor, finished even and fair without using extra cement Complete all as specified
M&L PCC 1:2:4 type B1 using 20 mm graded agg as in hard standing floor, 40 mm thick finished even and smooth without using extra cement Complete all as specified.
M & L for PCC 1:2:4 type B0 using 12.5mm graded aggregate as in coping bed plate, kerbs of mud stopos, rounded or chamfered on edges Complete all as specified.
Extra for forming fair finished drain or channel 30cm widith of girth in cement concrete using extra cement incl forms mould mitred/stopped ends etc Complete all as specified.
M&L in repairs for 60mm thick rubber moulded coloured interlocking precast PCC pavers any colour of M-35 grade laid over 40mm th sand cushioning and joint filled with fine sand incl levelling, tamping and sweeping etc complete all as specified and directed
S&F in repair copper alloy bib taps chromium plated suitable for 15mm bore pipe with captain head Make-Jaquar or equivalent of marc or parryware complete all as specified and directed and directed
Removal of vegetation growth bushes etc n. Exc 30 cm girth from the earth of any ht incl removal of its roots, branches and grass etc complete all as specified and directed.
M&L for TMT bars 10mm dia and over as in reinforcement cut to length bent to shape required including cranking, hooking ends and binded with steel wire (annealed) not less than 0.9mm dia ro secruing with clips confirming to Fe-410-0 or Fe-310-0 complete all as specified.
Demolition of reinforced concrete of any descriptionand in any postion not otherwise specifically provided far.
Material and labour for providing precast RCC 1:1.5:3 type A-1 using 20mm graded mechanically crushed stone agg as in cover slab for man holes, drains, soak well etc and similar articles etc, set in CM 1:4 with plain faces including chamfered weathering throating etc incl necessary form work complete as directed.
Supply and fixing in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, bore of pipe 110mm laid in trenches or in floors complete all as specified and as directed at site.
All as per item above but 75mm bore Complete all as specified.
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5 m depth and getting out complete all as specified and directed.
Excavation over areas but exc 3.00m and n exc 4.50 in depth and getting out in soft/ loose soil complete all as specified.
Returning , filling including spreading, levelling soil watering and ramming into layers n.exc 25cm thick complete all as specified and as directed.
Removal of excavated soil to a distance exc 250 but n. Exc 500M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed.
Taking up broken sewer line of any depth and replacing sewer pipe with RCC NP3 200MM including jointing of pipe in CM 1:1, haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded brick agg incl necessary excavation and earth work, disposal of material up to a distance of 50mtr and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified.
M&L Cutting into existing man holes for connection new drains, making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) min cement concrete 1 : 2 : 4 type B1 smooth finished and reforming benching.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finish flat surface Complete all as specified.
M&L for providing Reinforcement cement concrete type B1 1:2:4 (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like Complete all as specified.
M&L for Loose filling with brick aggregates of gauge 80 to 150 mm in soakage pits, soakage wells Complete all as specified.
Taking down carefullycopper/aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, sockets ceiling rose sketch light fittings etc, and making good the disturbed surface of walls and floors etc as directed.
Taking down carefully copper/aluminium sub main wiring/ service connection including teak wood batten/ conduit and making good the disturbed surface of walls as directed.
M&L Point wiring complete with 1.5 sqmm PVC (FRLS) insulated stranded copper conductor single core cable drawn through and including rigid non metalic PVC conduit and conduit accesseries fixed on walls/ceiling pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer plastic laminated top sheet cover 3 mm thick of required size and colour for housing switches, and sockets 1.5 sqmm PVC insulated (green insulation copper conductor) earth continuity cable drawn with wiring and connected to common earth dolly all as specified for :- (a) One light/fan point controlled by one switch complete all as specified.
(b) One socket out let point 5 Amp on an independent board complete all as specified.
(c) Same as item No 51 (b) but on the same board complete all as specified.
All as per item 51 (b) here in before but using 2.5 sq mm PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board.
S&F switch piano flush button single pole one way 5 Amp 240 volt complete as directed. (Make: Anchor Penta/SSK)
Ditto as item 54 but 15 Amps complete all as specified.
S&F socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed. (Make: Anchor Penta/SSK)
S&F ceiling rose surface bakelite three terminal complete as directed.
S&F socket outlet flush type 5 pin 5 Amps 240 volts complete as directed.
S&F angle type holder insulated body with back plate suitable for batten fittings as directed.
S&F MCB single pole & neutral 10 to 32 Amp 240 volts 10 KA breaking capacity complete as directed.
S&F MCB single pole 5 to 40 Amp 240 volts 10 KA breaking capacity complete as directed.
S&F in replacement sheet metal enclosure for DB’s when MCB, to be used, SPN, 12 ways 240 volt with 200 Amps rated bus bar made out of 16 Gauge sheet steel double door complete all as specified.Note:- (MCCB & MCB to be measured and paid seperately)
S&F in replacement sheet metal enclosure for DB’s when MCB, to be used, SPN, 8 ways 240 volt with 200 Amps rated bus bar made out of 16 Gauge sheet steel double door complete all as specified.Note:- (MCCB & MCB to be measured and paid seperately)
S&F in replacement sheet metal enclosure for DB’s when MCB, to be used, SPN, 4 ways 240 volt with 200 Amps rated bus bar made out of 16 Gauge sheet steel double door complete all as specified.Note:- (MCCB & MCB to be measured and paid seperately)
M&L for two single core PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit complete.(PVC Conduit and accessories shall be deemed to be included in the quoted rate) (Make of cable-Finolex/Havell's/Seiko)
M&L for two single core PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit complete.(PVC Conduit and accessories shall be deemed to be included in the quoted rate) (Make of cable-Finolex/Havell's/Seiko)
S&F in repair double door VTPN 4 way suitable for 4 pole MCCB as inoming & SP/TP MCB as outgoing, 200 Amps rated busbar, inter connection link, cable ties, earth bar etc complete all as specified and directed by Engr-in-charge. Note:- (MCCB & MCB to be measured and paid seperately)
Taking down carefully ceiling fan/ Exhaust fan of any type from location and re-fixing back after rewinding with copper wire as per gauge of wire used by the manufacturer complete all as directed.
Supply and fixing in replacement of LED fitting 1X20 Watts for 1XT LED lamps single side connection 4 feet in replacement of tube light fitting hanging with roof including complete accessories for hanging with separate 1 Nos LED tube 20 Watt complete all as specified and as directed.Make- Philips havells/ Bajaj or equivalent
M&L in repaira Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Part-I 1991 print and as directed .
Supply & fix fan regulator electronic step up Socket type for ceiling fan fixed, in existing board and connecting as directed, after dismantling and removing unserviceable surface type regulator.(Make-Anchor//Philips)
Supply and fixing in repair sheet metal enclosure with socket plug top and MCB with two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts 10KA breaking capacity pole complete all as directed.
S&F in repaitrs environmental friendly , new generation aesthetically designed , ultra modern recess mounting luminarie 2 x 2 feet with high brightness SMD LEDs 34/36 watt as light source suitable for armstrong / grid ceiling complete all as specified and directed at site.
S&F in repairs MCCB 63 Amp 415 volt 4 pole 16 KA.Make- C&S/Havells
S & F in repair LED Street light 25 Watt (>90 lumen/watt) PDC housing, IP65 with 4 KV inbuilt surge protection including copper flexible wire twin core 23/0.0076 & all necessary fixing accessories such as bracket of GI pipe light grade as per suitable size along with all accessories, fixed on wall including bolts & nuts. Make:-CG/HPL/C&S
S & F in repair LED bulk head fitting environmental friendly,IP-65, ultra modern, energy saving, surface mounting, decorative ovel comprising of high brightness LEDs 10 Watt, 6000K All as specified. Make- Havells/CG/philips
M/S Reliance Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .