Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.3 L+₹2.8 L (14.5%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NEW DELHI
CWE NEW DELHI
REPAIR AND REPLACEMENT AND MAINT OF LIFT FACIA LANDING DOORS LIFT CAR DOORS POLISHING BUFFING AND OTHER ALLIED WORKS AT AHRR UNDER GE EM RR HOSP DELHI CANTT-10
2025_MES_697869_1
CWE-ND/67/2024-25
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
RR HOSPITAL DELHI CANTT
REFER TENDER
9 documents required · 9 mandatory
₹500
GE E/M RR HOSPITAL
₹50,000
Yes
8 May 2025
14 Feb 2025
15 Mar 2025
14 Feb 2025
13 Mar 2025
1 Mar 2025
Amount
Dismantling/taking down old unserviceable car door and supply, fixing, testing, commissioningof complete car door SS hairline finish metal sheet (18 Gauge approx) SS 304 and scratch resistant as per existing size and model including complete door operator assembly for smooth opening of car doors suitable for 26 passanger cum stretcher lift (Make: Thyseen Elevators) with 2 hours fire rating, with gate lock, door shoeand other fittings as per site requirement complete all as specified and directed by Engr-in-Charge (Make: As per OEM recommendation) Note: (i) rate quoted by contractor are deemed to be inclusive of minor spares such as gate lock, door roller, door shoe, door rope etc and any other civil work required at site for taking down old door assembly and fixing new one and making good disturbed surfaces complete as per direction. (ii) Any damage done by contractor shall be replaced with same make and model of the door sensor while taking down and rectify the same free of cost by contractor.
Dismantling/taking down old unserviceable landing door and supply, fixing, testing, commissioning of complete landing door SS hairline finish metal sheet (18 Gauge approx) SS 304 and scratch resistant as per existing size and model including complete door header assembly i.e door hander roller and landing sill for smooth opening of landing door suitable for 26 passanger cum stretcher lift (Make: Thyseen Elevators) with 2 hours fire rating, with gate lock, door shoe and other fittings as per site requirement complete all as specified and directed by Engr-in-Charge (Make: As per OEM recommendation) Note: (i) rate quoted by contractor are deemed to be inclusive of minor spares such as gate lock, door roller, door shoe, door rope etc and any other civil work required at site for taking down old door assembly and fixing new one and making good disturbed surfaces complete as per direction. (ii) Any damage done by contractor shall be replaced with same make and model of the door sensor while taking down and rectify the same free of cost by contractor.
Dismantling/taking down old unserviceable landing door and supply, fixing, testing, commissioning of complete landing door SS hairline finish metal sheet (18 Gauge approx) SS 304 and scratch resistant as per existing size and model including complete door header assembly i.e door hander roller and landing sill for smooth opening of landing door suitable for 20 passanger cum stretcher lift (Make: Thyseen Elevators) with 2 hours fire rating, with gate lock, door shoe and other fittings as per site requirement complete all as specified and directed by Engr-in-Charge (Make: As per OEM recommendation) Note: (i) rate quoted by contractor are deemed to be inclusive of minor spares such as gate lock, door roller, door shoe, door rope etc and any other civil work required at site for taking down old door assembly and fixing new one and making good disturbed surfaces complete as per direction. (ii) Any damage done by contractor shall be replaced with same make and model of the door sensor while taking down and rectify the same free of cost by contractor.
Material and labour for removal of dust, stain marks, scratches, on stainless steel surface of car cabin including ceiling and carry out scrubbing, polishing, buffing of stainless steel polish liquid and buffing tool to give glossy and clean finish to lift cabin surface of 20/26 passanger cum stretcher lift complete all as specified and as directed.
Material and labour for removal of dust, stain marks, scratches, on stainless steel surface of landing door including landing frame and carry out scrubbing, polishing, buffing of stainless steel polish liquid and buffing toolto give glossy and clean finish to lift cabin surface of 20/26 passanger cum stretcher lift complete all as specified and as directed.
M&L for replacement of handle bar of all sides of size 35 mm and above in 20/26 passanger cum stretcher elevator by taking down old unserviceable bar complete all as specified and as directed.
S&F acrylic board for writing lift instruction including writing instruction as directed and fixing the acrylic board inside car cabin with the help of screws/studs complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
Demolition of un-reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified
M&L rendering 15mm thick in CM 1:4 on external fair faces of brick work or concrete surface to fair and even without using extra cement complete all as specified and as directed
M&L for sand-faced plaster as complete all as specified
Providing & applying two coats of Acrylic Elastomeric Exterior waterproofing compound of “Dr. Fixit Raincoat” or equivalent approved make and one coat of approved priming coat as per the waterproofing coating manufacturer to vertical wall/floor surfaces at any level and location including scaffolding etc. complete, as per instruction of the Engineer in Charge.
(a) M&L clean the surface, remove dust dirt, loose particles and unsound substrate and providing 20 mm thick cement screed (1:4) mixed with Dr Fixit or equivalent tonic liquid 200 gram/Bag over Dr Fixit or equivalent as approved by GE. (b) Applying primer coat with solvent based Bitumen primer @ 0.5 ltr/sqm. (c ) Dr Fixit or equivalent as approved by GE torch shield water proofing 3mm thick membrane use gas burner to heat substrate, press firmly from lower end to upper and with 100 mm overlap. (d) Heat both over lap with round tipped trowel to seal over lap . Excess compound smoothened, pressed into seam using hot trowel. (e) Seal edges well into grooves & protect with a poly sulphide sealant. (f) M&L hydraulically pressed burnt clay tiles plain size 300X300X19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM 1:3 mixed with crude oil. (Note 1 :- WPC as per manufacturer's instruction shall be deemed to be included in unit rate quoted.) (Note 2 : Water proofing treatment shall be carried out through approved manufacturer's applicator). (g) Uploading of material shall be carried out by mechanical means, use of staircase is strically probihited
Treatment of roof with reinforced elastomeric liquid waterproofing membrane of 400micron thickness having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371, respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat yp!e 1200C as per IS: 101 (P-7/Sec-3) 1990 having VOC less than as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 3.5 bars of pressure for 7-days.lt should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide, along with water and soap solution as per IS: 101 (P-7/Sec-2)1990. The waterproofing membrane will be laminated with 25—40-micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P-8/Sec-6) 1993 and also should pass Impact test as per IS: 101 (P5/Sec-3) 1988 along with having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS: 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS: 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self-cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes pressure wash cleaning to remove all dust, fungus, etc., with pressure washer after repairing the existing roof having old bitumen membrane by filling cracks, potholes, holes with waterproofing compound having compressive strength as per IS-4031 part-6-1988 & permeability of water as per IS2645-2003 .
Providing and laying cement concrete floor (Indian Patent Stone) 40 mm to 65 mm thick to maintain required slope, P.C.C.(1:2:4) mix using 12.5 mm graded stone aggregate, adding fiber mesh @125 gms/cement bag and sunplex @ 330 gms /cement bag laid in alternate bays troweled smooth on top in neat cement and making lines on the top surface diagonally or square at spacing, curing for minimum 7 days, as directed etc. complete.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 with old size bricks
M&L rendering 15mm thick in CM 1:6 on external fair faces of brick work or concrete surface to fair and even without using extra cement complete all as specified and as directed
S&F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each pane
M&L for preparation of newly plastered surface of wall and applying two coat of weather proof exterior emulsion extra premium 100% acrylic emulsion as approved over a coat of primer complete all as specified and directed.
Material and labour for machine cut kota stone flooring 20-25 mm thick of approved size over cement screed base, laid and jointed with grey cemented slurry mixed with pigment to match the shade of slab including rubbing and polishing(mirror), complete all as directed.
Material and labour for 20 mm thick screed bed or bedding layer in cement Mortar 1:6 for laying kota stone floor finishes, complete all as directed.
M&L for replacement of TIC II controller circuit plate with TIC V controller circuit plate of 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) including programming for all safety features complete all as specified and directed.
M&L for replacement of TIC II controller Drive with TIC V controller drive of 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) complete all as specified and directed.
M&L for replacement of TIC II compatible ARD/UPS and battery with TIC V compatible ARD with UPS of 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) complete all as specified and directed.
M&L for replacement of travelling cable of 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) compatible with TIC V panel complete all as specified and as directed.
M&L for replacement of TIC II based contactor, MCB, relays with TIC V based contactor, MCB, relays for 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) including any other part required for proper functioning of lift complete all as specified and directed.
M&L for replacement of complete control wiring and power wiring of TIC II panel with wiring suitable for TIC V panel of 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) complete all as specified and directed.
M&L for replacement of LOP and COP set of all floor 26 Passanger B+G+4 passanger cum stretcher lift (Make: Thyseen Elevators) compatible with TIC V panel complete all as specified and directed.
M&L for fixing mirror 5 mm thick backside polised inside car cabin with the help of screw/studs complete all as specified and as directed
S&F in replacement of speaker of lift including wiring by taking down old speaker complete all as specified and directed.
M&L for replacement of earthing with Galvanised Steel earth plate electrode of size 600 x 600 x 6mm thick directly burried in ground (earth pit not less then 4Mtr deep below ground level with tope edge of earth plate not less than 1.5 Mtr below the ground level connected by GI Earth Strip of Size 32x 6mm thick by means of Bolts, Nut,Check Nuts and Washer of GI or Steel GI Pipe 40mm Bore light grade for protection of earthing strip, PCC CHAMBER 1:4:8 TYPE D-1 using 20mm graded stone agg. Internal surfaces of chamber shall be plastered 12mm thick in CM 1:4 funnel with wire guage of 22 guage(0.63mm) 8 mesh per linear inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm grade stone agg. reinforced with 8mm dia TMT Bar @80mm C/C both ways and charcoal dust and common salt all as specified and shown in electrical plate No of 5 of SSR part-I including excavation of earth work, returning , filling, removing surplus soil not exc 50 m and connecting the earthing to an earthing test point as specified and testing on completion. Note: i) Quoted rate will deemed to be included for cost of adequate quantity of charcoal dust, common salt and Testing commissioning including checking of earth continuity and earth result . ii) Cost of Main earthing lead & protection pipe from earth electrode to test point upto 7.5 metre will deemed to be included in quoted rates. iii) On testing after completion if the desired earth resistance is not obtained, the earthing will be redone without any extra cost.
Supply & fix in repair GI strip 32x6mm, buried in ground or fixed to wall incl saddling etc for loop earthing complete all as specified and directed.
M/s Dhapola Elevator and Engineering (BID ID -3261186)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .