Loading…
Loading…
Tender Value
₹2.3 L
EMD Value
₹4,660
Closing Date
3 Aug 2026, 6:00 pm
Executive Engineer PWD(RandB)nagrota Jammu
Executive Engineer PWD(RandB)nagrota Jammu
Furnishing of Cabin at SDH Hospital ay Jagti by way of providing false ceiling, Air Condition, wall mounting fan and False ceiling light.
2026_PWDJK_315669_3
Short e-NIT No. 40 of 2026-2027/Nagrota Dated 11-07-2026
Open Tender
Civil Works
30 days
Executive Engineer PWD(RandB)nagrota Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD(RandB)nagrota Jammu
₹4,660
Yes
11 Jul 2026
11 Jul 2026
4 Aug 2026
11 Jul 2026
3 Aug 2026
13 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Window AC's (copper) Cold type of minimum capacity following Specification as detailed below. 1. Should be of inverter type 2. Cooling capacity (in Tr): 1.5 3. BEE Star rating: 5 4. Maximum local temperature: 52 C 5. Rated cooling capacity (BTU/hr.): 19000 or above 6. Condensing coil: 100% Copper with grooved copper tubes 7. Electrical input, 220 V ± 30/50Hz/Single Phase 8. Noise level (indoor unit): = close to 35 dB 9. Compressor type: rotary or any other suitable technology 10. Refrigerant type: R-32 11. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent 12. Compressor Warranty: 10 years 13. PCB Warranty: 5 year 14. Total System Warranty: 1 year 15. Minimum noise level of the indoor unit should be around 28 dB (A) 16. Should have air filtering mechanism for removing dust 17. Supplier has to include brochure of the quoted model Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required. | - | Each | - | - |
| 2 | Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.: 2 Years from the date of installation. 5 KVA. | - | Each | - | - |
| 3 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tilesof Size 595x595mm of approved texture, design and patterns havingNRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS8225:1987, Light reflectance of 85% (minimum). Non combustible asper BS:476 (part-4), fire performance as per BS:476 (part 6 &7),
humidity resistance of 100%, thermal conductivity < 0.043 W/m K asper ASTM 518:1991,in true horizontal level suspended on interlockingmetal T-Grid of hot dipped galvanised iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising ofmain-T runners of size 24x38 mm of length 3000 mm, cross - T of size24x32 mm of length 1200 mm and secondary intermediate cross-T ofsize 24x32 mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanised mild steel items(galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameterM-6 dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mmlength and L-shape level adjuster of size 85x25x25x2 mm. Galvanisediron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm tobe fixed on periphery wall / partition with the help of plastic rawl plugsat 450mm center to center and 40 mm long dry wall S.S screws. Thework shall be carried out as per specifications, drawing and as perdirections of the Engineer-in-Charge.31.20.1 With 15 mm thick tegular edged light weight calcium silicatefalse ceiling tiles. | - | Sqm | - | - |
| 4 | S/F of 2'x2' False ceiling light with Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A | - | Each | - | - |
| 5 | S/F ofwall mounted fan with Wiring for lfan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A | - | Each | - | - |
| 6 | Supplying and fixing suitable size Gibox with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | - | Each | - | - |
| 7 | Wiring for electric point and other points. | - | Rmt | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
BOQ_1024704.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid