| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAdmitted-Finance | ₹4.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.1 Cr+₹43.7 L (9.34%)Admitted-Finance A 41 HIRALAL NAGAR NEAR DIXIT SWEETS SAROJINI NAGAR KANPUR ROAD LUCKNOW UTTAR PRADESH 226008 | LUCKNOW | UTTAR PRADESH | 226008 | ₹5.1 Cr+₹43.7 L (9.34%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically non-responsive |
| Sl No | Description | Qty | Unit | Alliance Transcon Pvt. Ltd. L2 | M/s Pragya Electric and Electronics Corporation L1 |
|---|---|---|---|---|---|
| 1.00Improvement /Revamping of 33/11kv - (3x10 MVA) Receiving Station Reasi Trintha | |||||
| 2.00 | Laying of Compound boundary wall of out door switch yard by way of mass concrete in foundation and brick work of reqd. height | 30 | RM | 8,000 ₹2,40,000 Lowest | 9,440 ₹2,83,200 |
| 3.00 | Face lifting / Repair work /Roof Treatment of existing control room building and SBA Room along with painting /replacement of Broken doors and window / window panes/Electric fitting along with replacement of old power point with modular switches ,sockets and MCB'S . | 1 | job | 4,00,000 ₹4,00,000 | 3,54,000 ₹3,54,000 Lowest |
| 4.00 | Extension of existing control room building /Battery Room / SBA Room along with construction of new washroom with septic tank/Sanitary works/plumbing complete job | 750 | Sq. ft. | 2,500 ₹18,75,000 Lowest | 3,540 ₹26,55,000 |
| 5.00 | 33KV Lightening Arrestors(33 KV 10 KA Polymer, ZnO, Gapless) | 2 | set | 25,000 ₹50,000 Lowest | 29,500 ₹59,000 |
| 6.00 | LT Cable 3.5 Core 95 mmsq | 100 | mtr | 750 ₹75,000 Lowest | 2,065 ₹2,06,500 |
| 7.00 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories at receving station Dharmari . | 1 | no | 60,000 ₹60,000 Lowest | 70,800 ₹70,800 |
| 8.00 | Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),Rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories at receving station Dharmari . | 1 | No. | 75,000 ₹75,000 | 70,800 ₹70,800 Lowest |
| 9.00 | 11Kv Gapless surge arrestor 9kv , 10KA,LA with polymer housing station type . | 3 | set | 5,000 ₹15,000 Lowest | 5,900 ₹17,700 |
| 10.00 | Earthing with 600mm*600mm GI plate , GI Flat 50*6mm, GI pipe ,40mm dia with charcoal salt and good earth 10 feet deep pit etc as per REC Standard complete3 job. of Switch Yard and control Room | 4 | Nos | 10,000 ₹40,000 | 9,440 ₹37,760 Lowest |
Tender Value
Refer Docs
EMD Value
₹10.4 L
Closing Date
10 Jul 2026, 2:00 pmClosed
Executive Engineer STD Udhampur
Sub Transmission Division JPDCL Udhampur
Attached
2026_PDD_312767_1
11 of 2026-27
Open Tender
Electrical Works
Item Rate
90 days
Pouni
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Executive Engineer STD Udhampur
₹10.4 L
24 Jul 2026
17 Jun 2026
11 Jul 2026
17 Jun 2026
10 Jul 2026
17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Improvement /Revamping of 33/11kv - (3x10 MVA) Receiving Station Reasi Trintha | - | - | - | - |
| 2 | Laying of Compound boundary wall of out door switch yard by way of mass concrete in foundation and brick work of reqd. height | 30 | RM | - | - |
| 3 | Face lifting / Repair work /Roof Treatment of existing control room building and SBA Room along with painting /replacement of Broken doors and window / window panes/Electric fitting along with replacement of old power point with modular switches ,sockets and MCB'S . | 1 | job | - | - |
| 4 | Extension of existing control room building /Battery Room / SBA Room along with construction of new washroom with septic tank/Sanitary works/plumbing complete job | 750 | Sq. ft. | - | - |
| 5 | 33KV Lightening Arrestors(33 KV 10 KA Polymer, ZnO, Gapless) | 2 | set | - | - |
| 6 | LT Cable 3.5 Core 95 mmsq | 100 | mtr | - | - |
| 7 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories at receving station Dharmari . | 1 | no | - | - |
| 8 | Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),Rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories at receving station Dharmari . | 1 | No. | - | - |
| 9 | 11Kv Gapless surge arrestor 9kv , 10KA,LA with polymer housing station type . | 3 | set | - | - |
| 10 | Earthing with 600mm*600mm GI plate , GI Flat 50*6mm, GI pipe ,40mm dia with charcoal salt and good earth 10 feet deep pit etc as per REC Standard complete3 job. of Switch Yard and control Room | 4 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
SBDPouniLine.pdf
Tender Documents • 7.41 MB
BOQ_1012325.xls
BOQ • 0.27 MB
CorrigendumPaymentandcompletion.pdf
PDF • 0.21 MB
CORRPouniExtension_1.pdf
PDF • 0.18 MB
CORRPouniTech_1.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .