Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.2 L+₹16,100 (0.45%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.7 L+₹3.7 L (10.3%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹42.3 L+₹6.3 L (17.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.9 L+₹6.9 L (19.0%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹79,960
Closing Date
5 Sept 2024, 6:00 pmClosed
Garrison Engineer Air Force
Military Engineer services AF Stn Adampur 144103
REPAIR / REPLACEMENT TO LT PANELS AND CONNECTED WORKS AT AF STN ADAMPUR
2024_MES_665981_1
GE/AF/ADM-24/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Under GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹79,960
Yes
12 Nov 2024
15 Jul 2024
6 Sept 2024
15 Jul 2024
5 Sept 2024
30 Jul 2024
16 Jul 2024 - 29 Jul 2024
Amount
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 25 X 4 mm GI strip earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.1 of contract, IN REPAIRS. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as 25x4 mm GI strip. complete all as specified, IN REPLACEMENT,
LT panel board, indoor type, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 500A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Aluminium bus bar of 600 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 400 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 200 Amp, 36 kA - 03 Nos. (Outgoing). (g) MCCB 4 pole, 415 volt, 160 Amp, 16 kA - 02 Nos. (Outgoing).
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 500A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Aluminium bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 200 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 160 Amp, 36 kA - 02 Nos. (Outgoing). (g) MCCB 4 pole, 415 volt, 100 Amp, 16 kA - 01 No. (Outgoing).
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 500A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Aluminium bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 250 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 200 Amp, 36 kA - 01 No. (Outgoing). (g) MCCB 4 pole, 415 volt, 160 Amp, 16 kA - 01 No. (Outgoing). (h) MCCB 4 pole, 415 volt, 63 Amp, 16 kA - 02 Nos. (Outgoing). (j) On load chang over switch 4 pole, 415 volt,50 Hz- 01 No
LT outdoor type, loop in loop out box, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Aluminium bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 250 Amp, 36 kA -01 No.
LT outdoor type, loop in loop out box, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Aluminium bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 125 Amp, 16 kA -01 No.
LT outdoor type, loop in loop out box, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, comprising the following components/acessories: - (a) Aluminium bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 63 Amp, 16 kA -01 No.
Bus Bar Box (Junction Box), with sloping canopy, CPRI approved all as specified in particular specifications of contract clause 19.4 including installation, commissioning & testing, IN REPLACEMENT, complete
Taking shutdown from MES, disconnecting all electric connections and opening of LT panel of any description for repair etc., reassembling of the same after all necessary repair, refixing, replacement of unserviceable components, reconnecting, commisioning and testing to the entire satisfaction of Engineer-in-Charge. NOTE: Supply only spares/components will be measured and paid for separately under respective items of BoQ.
Supply only LED lamp, RYB indication complete all as specified.
Supply only MCCB suitable for 415 volts AC supply, 50 Hz, 4 pole with over load and short circuit protection, adjustable thermal & adjustable magnetic release type, complete all as specified of following rating: -
63 Amp, 16 kA.
100 Amp, 25 kA.
160 Amp, 16 kA.
200 Amp, 36 kA.
250 Amp, 36 kA.
400 Amp, 50 kA.
630 Amp, 50 kA.
Cutting out existing worn out/ damaged CRCA sheet of LT panel board and providing new CRCA sheet of thickness not less than 3 mm including necessary welding, sheet metal repair work and applying a coat of anti corrosive primer after preparation of surfaces complete.
Making LT panel doors operateable to the entire satisfaction of Engineer-in-Charge by providing new hinges of existing size & pattern including necessary welding, sheet metal repair work and applying a coat of anti corrosive primer after preparation of surfaces and filling the undulation with ready made putty for MS/steel surfaces, complete.
Two coats of synthetic enamel paint applying a coat of anti corrosive primer after preparation of surfaces with spray gun including preparation of surfaces and filling the undulation with ready made putty for MS/steel surfaces and a coat of red oxide primer complete.
NOTES FOR SERIAL ITEM 10 TO 11: Repair work & painting to LT panel shall be carried out after taking necessary power shutdown from MES
NOTE: (i) To maintain utmost security at AF Station, contractor will arrange his workmen along with T&P in a manner that nonfunctional Fault of LT line & panel is made functional swiftly within 24 hour of receiving of complaint from the MES, during entire contract period. (ii) Not withstanding with the provision of "Compensation for Delay' envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation @ Rs. 500/- day will be charged from contractor in case he fails to make the LT line & panel functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working LT line & Panel.
ARUNOTHAYA TRADERS (BID ID -3087334)
Northern cable fault locatoers (BID ID -3084294)
Building Block Constructions (BID ID -3087994)
J.K & Company (BID ID -3087254)
Flint India (BID ID -3086611)
TARA ENTERPRISES (BID ID -3086188)
M/S JAI ENGINEERS (BID ID -3087292)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .