14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender.
A.Definition of 'Similar Nature of Work':- "Erection, Testing, and commissioning of 132kv and above voltage transmission line & Erection, Testing, and commissioning, Modification of at least one Bay of 132kv and above voltage at GSS end".
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Design, Supply, erection, testing & commissioning of 132KV D/C 3-phase transmission line from GSS Sonenagar (old) to Railway TSS Sonenagar and associated 02 nos. 132KV Line Bays at GSS Sonenagar (old) under Railway Project Danpaur of East Central Railway.
RPECRDNRTRLSEBRETEND-2~ECR
RPECRDNRTRLSEBRETEND-2
Open
Works - General
18 Months
Patna, Bihar
₹0
₹10.7 L
14 Jan 2026
22 Dec 2025
31 Dec 2025
433 items across 8 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,03,42,424.64 | ||
| — | — | — | 23,70,195.3 | ||
| 132 kV EQUIPMENT 1Circuit breaker (3 phase) i)a 1250 A, 31.5 kA SF 6 CB with support structure, marshalling boxes, terminal connectors etc.(current rating shall be equial to the current rating for which the short cuircuit test reports shall be furnished.) (Spring- Spring ) | — | 2.00 | — | — | |
| — | — | — | 8,96,409.96 | ||
| 2 ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only. 2. i)a 1250 A, 31.5 kA with one earth switch (Double break Isolator) | — | 2.00 | — | — | |
| — | — | — | 13,48,003.84 | ||
| 2. ii)a 1250 A, 31.5 kA without earth switch (Double break Isolator) | — | 4.00 | — | — | |
| — | — | — | 1,23,717.24 | ||
| Portable discharge rods (1 Phase) | — | 6.00 | — | — | |
| — | — | — | 24,85,408.02 | ||
| 4 Current Transformers 5 core (1 phase)4. i)a 1200 -600-300-150/1-1-1-1-1 A, 5 core 0.2S class ,31.5 kA with 120% extended current rating with marshalling boxes, terminal connectors etc. | — | 6.00 | — | — | |
| — | — | — | 19,53,768.78 | ||
| 5 8800 pF CVTs (1 phase) with marshalling boxes, terminal connectors etc. | — | 6.00 | — | — | |
| — | — | — | 3,78,349.56 | ||
| Pg No-17 Sl No-C-1. 6 120 kV Surge arrestersSH class-IV ( 1 phase) with marshalling boxes, terminal connectors etc. | — | 6.00 | — | — | |
| — | — | — | 17,74,475.98 | ||
| C-2 (Pg 17)/ERECTION HARDWARE (132 kV)/1.1 Insulator strings antifog type & hardware, spacers, conductor (S), Bus bar material, cable trays, bay MB, Clamps, Connectors including, Junction box,PVC pipes for equipment and lighting, all accessories etc. for the following (main bus shall be of quad Moose conductor and transfer bus shall be strung with double Moose conductor)/132 kV Main & Transfer bay/ I Line bay | — | 2.00 | — | — | |
| — | — | — | 1,19,192.32 | ||
| IV Bus (for fifteen bays-10 bays now and 5 bays for future extn) (one for main bus & another for transfer bus) (supply cost of Bus for bay is calculated by unitary method ) | — | 2.00 | — | — | |
| — | — | — | 2,87,305.02 | ||
| 1.2 132 kV Solid Core, Bus post Insulators for erection hardware | — | 18.00 | — | — | |
| — | — | — | 43,41,726.9 | ||
| F (Pg 19)/CONTROL & RELAY PANELS/2 132 kV (Duplex Panels)/ 2.1 Control, Relay & Protection Panel for/a)132 KV line (with A/R) with numerical distance protection relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare. All indicating meters/ multifunctions meters shall be communicable tpe with 0.5 class accuracy. | — | 2.00 | — | — | |
| — | — | — | 4,572.64 | ||
| (Pg. 38)/ RTU/ 8 Heavy Duty Relay | — | 8.00 | — | — | |
| — | — | — | 6,762.4 | ||
| 9 Contact Multipyling Relay (CMRs) | — | 16.00 | — | — | |
| — | — | — | 27,423.68 | ||
| 10 Multi Function Meters (MFMs) | — | 2.00 | — | — | |
| — | — | — | 14,015.67 | ||
| 13 Analog Input Module (4 channels/card) | — | 1.00 | — | — | |
| — | — | — | 13,942.26 | ||
| 14 Digital Input Module (16 channels/card) | — | 1.00 | — | — | |
| — | — | — | 14,755.73 | ||
| 15 Digital Output Module (8 channels/card) | — | 1.00 | — | — | |
| — | — | — | 3,83,557.9 | ||
| 19(b)/ 14Cx1.5 sq.mm armoured cable (Digital i/p) | — | 0.50 | — | — | |
| — | — | — | 2,03,729.23 | ||
| 19©/ 7Cx1.5 sq.mm armoured cable (Digital i/p) | — | 0.50 | — | — | |
| — | — | — | 1,33,508.72 | ||
| 19(d)/ 4Cx2.5 sq.mm armoured cable (Digital o/p Trip/Close) | — | 0.50 | — | — | |
| — | — | — | 2,70,692.96 | ||
| H-1 (Pg 19)/ Batteries (VRLA Type)(AT TSS End)/1.2 a)/48V 300AH | — | 2.00 | — | — | |
| — | — | — | 11,48,753.82 | ||
| H-2 (Pg 20)/Battery charger system(At TSS End)/1.2 a)/48V, 30/20 A float and float cum boot charger | — | 2.00 | — | — | |
| — | — | — | 4,52,617.78 | ||
| Pg No-18 Sl No- E. vi/48V DCDB | — | 1.00 | — | — | |
| — | — | — | 1,08,450.36 | ||
| : L (Pg 24)ILLUMINATION SYSTEM/L-3/ Outdoor lighting (Switchtard & street lighting)/Lighting fixture and receptacles ( including accessories/ materials etc. as per requirement like junction box, cable/ wires, flexible conduits (if required) from box to lighting fixtures, mounting arrangements)/a Lighting fixture type- SF1 as per Tech specification | — | 4.00 | — | — | |
| — | — | — | 64,190.92 | ||
| b Lighting fixture type- SF2 as per Tech specification | — | 4.00 | — | — | |
| — | — | — | 3,98,858.29 | ||
| M (Pg 24)/Cables alongwith associated accessories like clamps, glands, lugs and straight joints etc./ 1.2/ Power cables (PVC) 1.1 kV / b. 3.5C X 35 mm2 | — | 1.00 | — | — | |
| — | — | — | 2,24,340.87 | ||
| c. 4C X 16 mm2 | — | 1.00 | — | — | |
| — | — | — | 2,48,122.53 | ||
| e 2C X 6 mm2 | — | 3.00 | — | — | |
| — | — | — | 1,78,653.69 | ||
| 1.3 Control cable (PVC) 1.1 kV/b 3C X 2.5 mm2 | — | 1.00 | — | — | |
| — | — | — | 5,31,061.96 | ||
| C/ 5C X 2.5 mm2 | — | 2.00 | — | — | |
| — | — | — | 6,82,083.78 | ||
| d 7C X 2.5 mm2 | — | 2.00 | — | — | |
| — | — | — | 6,79,074.34 | ||
| Pg No-25 Sl No-M-1.3e/10C X 2.5 mm2 | — | 1.50 | — | — | |
| — | — | — | 12,66,438 | ||
| Pg No-25 Sl No-M-1.3.f/ 14C X 2.5 mm2 | — | 2.00 | — | — | |
| — | — | — | 92,06,658 | ||
| N (Pg 25)/Materials for earthing mat with all materials and accessories as well as spikes as per requirement of design as per IEEE standards for complete earthing of grid Sub-Station with the followings. (The quantity is tentative and final quantity will depend on actual design):-/ 1 40 mm MS rod for main earth mat | — | 72.00 | — | — | |
| — | — | — | 2,67,608.14 | ||
| 2 75x12 mm G.I Flats for risers for equipments, columns and structures | — | 2.00 | — | — | |
| — | — | — | 1,33,804.07 | ||
| 3 50x6 mm G.I flats for risers for all other equipments etc. | — | 1.00 | — | — | |
| — | — | — | 1,98,484.63 | ||
| 4 Materials for Earthing pits with supply of all earthing materials including base plate | Lumpsum | 0.10 | — | — | |
| — | — | — | 15,52,166.96 | ||
| O (Pg 25)/Sub- Station galvanized Steel structure (220 kV, 132 KV & 33 KV) (The quantity is tentative and final quantity will depend on actual design):-/2 Lattice structure with fasteners etc.(MS) | — | 11.44 | — | — | |
| — | — | — | 13,99,633.9 | ||
| 1 Lattice structure with fasteners etc.(HT) | — | 10.00 | — | — | |
| — | — | — | 20,99,450.85 | ||
| 5 Pipe Type structure | — | 15.00 | — | — | |
| — | — | — | 2,97,742.4 | ||
| P (Pg 25)/Cable Racks as per design requirement. | — | 2.00 | — | — | |
| — | — | — | 2,40,682.39 | ||
| P (Pg 25)/Cable Racks as per design requirement. | Lumpsum | 1.00 | 2,40,682.39 | — | |
| — | — | — | 2,72,731.44 | ||
| 4 Earth Pit(Treated) | — | 12.00 | — | — | |
| — | — | — | 78,179.52 | ||
| 5 Earth Pit(Non- Treated) | — | 8.00 | — | — | |
| — | — | — | 4,84,905.29 | ||
| W (Pg 27)/Mandatory spare for 220/132/33KV GSS (Break up of LS items furnished seperately in technical specification)/4 132KV CB | Lumpsum | 1.00 | 4,84,905.29 | — | |
| — | — | — | 3,15,160.07 | ||
| 7 132KV Isolator | Lumpsum | 1.00 | 3,15,160.07 | — | |
| — | — | — | 3,17,634.74 | ||
| 11 132KV CT, 1200A, 120% extended current rating | — | 1.00 | — | — | |
| — | — | — | 2,84,939.33 | ||
| Pg No-28 Sl No-15/132KV CVT, 8800 pF | — | 1.00 | — | — | |
| — | — | — | 58,482.46 | ||
| Pg No-28 Sl No-17/120 KV Surge arresters | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .