Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹95.2 LAccepted-AOC C 88 NIRALA NAGAR NEAR 8 NO CHAURAHA LUCKNOW 226 020 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226020 | 1 | Accepted-AOC AOC | |
| 2 | 2₹1.0 Cr+₹5.6 L (5.89%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 2 | Rejected-Finance Not being Lowest | |
| 3 | 3₹1.1 Cr+₹16.4 L (17.1%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | 3 | Rejected-Finance Not being Lowest | |
| 4 | 4₹1.1 Cr+₹18.0 L (18.8%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | 4 | Rejected-Finance Not being Lowest | |
| 5 | 5₹1.2 Cr+₹19.9 L (20.8%)Rejected-Finance C 9 53 SECTOR 8 ROHINI NEW DELHI 110085 | NEW DELHI | NEW DELHI | DELHI | 110085 | 5 | Rejected-Finance Not being Lowest |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
16 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT LUCKNOW
AUGMENTATION/IMPROVEMENT OF ELECTRIC SUPPLY DISTR SYSTEM FOR LUCKNOW CANTT
2021_MES_444070_1
CWE/LKO/EM/T-13 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
Lucknow
MES contractors enlisted in Class B and category b(i) and for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹1,000
GE EM LUCKNOW
₹2.2 L
Yes
28 Jun 2021
19 May 2021
17 Jun 2021
19 May 2021
16 Jun 2021
4 Jun 2021
60 days
Amount
Supplying,laying, fixing,jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 4 core laid in trenches/ laid under floor or fixed naked with walls/ on poles/ in ducts /in GI pipes etc. with and including MS clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under respective items.
All as item No-1 above but size 16 sq mm 4 core
All as item No-1 above but size 25 sq mm 4 core
All as item No-1 above but size 50 sq mm 3.5 core
All as item No-1 above but size 95 sq mm 3.5 core
All as item No-1 above but size 120 sq mm 3.5 core
All as item No-1 above but size 240 sq mm 3.5 core
Supplying, laying, fixing, jointing, testing and commissioning HT under ground electric power cable Crossed linked polyethylene ( XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 95 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc. complete all as specified and directed. Note :- Excavation/ boring of raod/ pipe shall be measured and paid separately under respective items.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
Supplying & Laying un-reinforced precast concrete cable protection covers of class HVP, type-1, flat, of size 300mm x 180mm x 40mm perpendicular to the axis of the cable, for protection of cable complete all as specified and directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
Boring/Drilling ( horizontally) manually under existing road (maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
Supply & Fixing Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc complete all as specified and directed.
All as item Srl No-16 above but 50 mm bore size.
All as item Srl No-16 above but 80 mm bore size.
Material & labour for boring of holes under road, pavement, hard standing by trenchless technology for laying/passing of HT cables using ultra sounding technique and necessary machine under roads/ hard standing complete all as specifed and directed. Note:- If any damages to existing services such as OFC cable/ Gas pipe line/ Electric cable etc shall be repaired immediately by the contractor. Rate quoted against this item shall be deemed to be included for this purpose.
M & L for 150 mm thick, plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in copping of poles complete all as specified and directed.
Supply and errection of 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick conforming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps, Cat NO: HM-1107 P for pole and HM-SA 1 M for bracket. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type in 1:2:4 type B-1 as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 60 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set suitable for pole mounting bracket 40 mm. complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 90 watt conforming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficiency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set suitable for pole mounting bracket 40 mm. All relevent documents related to luminaries and driver needed to submit for approval complete all as specified and directed.
S&F in repair flat twin core ,10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable complete all as specified and directed.
All as item No 25 above but 4.0 sqmm size.
All as item No 25 above but 6.0 sqmm size.
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination including sleeves heat shrinkable joint suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified and directed.
All as item No 28 above but size 70 to 120 sqmm.
All as item No 28 above but size 120 to 240 sqmm.
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified and directed.
All as item No 31 above but size 70 to 120 sqmm.
All as item No 31 above but size 120 to 240 sqmm.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 sqmm complete all as specified and directed.
Supply and fixing Cable route indicator made out of PCC block and properly painted as per approved colour in PCC (1:3:6) type C-1 using 20 mm graded stone aggregated of size 900 mm x 300 mm x 100 mm thick ( 45 cm burried in ground) with DANGER / 1.1 KV CABLE MES embossed on rout marker including excavation and earth work complete all as specified and directed.
Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The TPN busbar shall be insulated with colour coaded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of theTPN busbar. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator. Contd.......
All inter connections between the main busbar as well as outgoing feeder shall be carried out with TPN aluminium busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves comprising of the following:- (a)The TPN busbar duly plated copper busbar fitted in cascaded moulding. (b) Incoming MCCB 400 Amps 36 KA, 415 volts, FP - 01 Nos (c) Outgoing MCCB 250 Amps 25 KA, 415 volts, FP - 03 Nos (d) Outgoing MCCB 200 Amps 25 KA, 415 volts, FP - 01 Nos (e) Voltage/Ampere/Frequency meter Digital meter - 01 No (f) LED indicator lamp RYB - 01 Set of three
All as per item No 38 above but comprising with following:- (a) The TPN busbar duly plated copper busbar fitted in cascaded moulding. (b) Incoming MCCB 250 Amps 25 KA, 415 volts, FP - 01 Nos (c) Otgoing MCCB 200 Amps 25 KA, 415 volts, FP - 03 Nos (d) Otgoing MCCB 160 Amps 25 KA, 415 volts, FP - 01 Nos (e) Voltage/Ampere/Frequency meter multi functional meter - 01 No (f) LED indicator lamp RYB - 01 Set of three
All as per item No 38 above but comprising with following:- (a) The TPN busbar duly plated copper busbar fitted in cascaded moulding. (b) Incoming MCCB 250 Amps 36 kA, 415 volts, FP - 01 Nos (c) Outgoing MCB 63 Amps 25 kA, 415 volts, FP - 08 Nos (d) Voltage/Ampere/Frequency meter multi functional meter - 01 No (e) LED indicator lamp RYB - 01 Set of three
Supply, installation, testing and commissioning out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. (a) TPN, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. (d) Necessary excavation, earth work, PCC 1:4:8 type D2 in foundation and PCC 1:3:6 type C2 platform complete all as required.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 mm dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 mm c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion complete all as specified and directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 20 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 of SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing complete all as specified and directed.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 250 x 200 x 150 mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulator including MCB SP 10Amp , 10 KA-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete including required size and length of copper conductor cable and making connections complete all as specified and directed.
Supply and fixing Verticle TPN DB IP-54 protection 4 way double door with MCCB FP 100 Amps, 16 KA, 415 Volt AC, 50 Hz,and sheet metal enclosure including MCB DP 40 Amp-06 Nos & isolated neutral Bar Amp complete with existing cabling network including making good disturbed surfaces complete all as specified and directed.
Supply and fixing in repairs wall mounted bus -bar three ph, 8 way , 415 Volts with 4 nos Aluminium Bus bar 200 Amp in sheet metal enclosere of 1.6 mm thick MS sheet with powder coated painting including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed.
M&L for submain wiring alongwith earth wire with the FRLS PVC insulated multistranded copper conductor cable 2x6 sqmm & 1x4 sqmm as earth wire with and including surface PVC casing caping of size not less than 20 mm complete all as specified and directed.
Supply & fixing of automatic street light timelite distribution board 40 Amp, 3 pole /230 V digital time switch for automatic switching of street lights based on conforming to IP-54 degree of including mounting bracket, cable glands, openable doors with lock complete all as specified and directed.
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and directed.
Dismantling of GI wire any type and any size complete all as specified and directed.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and directed.
Dismantling of insulators any type and any size complete all as specified and directed.
Dismantling of PCC/Steel Poles any type and any size complete all as specified and directed.
Dismantling of stay assembly any type and any size complete all as specified and directed.
M/S S.B. Singh and Sons
POONAM ELECTRIC INDUSTRY
M/s J P Traders
AMIT ASSOCIATES
Leo Air and Power Solution pvt Ltd.
M/S J J ENTERPRISES
SHALABH INDIA INDUSTRIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .