Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18,900Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹24,375+₹5,475 (29.0%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S CLEAR LINE ENGINEERS CONTRACTOR L1 | MAHALAXMI TRANSFORMER INDUSTRY L2 |
|---|---|---|---|---|---|
| 1.00 | Unloading of damaged distribution transformer (25/63/100KVA) | 1 | Job | 100 ₹100 | 93 ₹93 Lowest |
| 2.00 | Unloading of damaged distribution transformer (200/250KVA) | 1 | Job | 100 ₹100 Lowest | 129 ₹129 |
| 3.00 | Unloading of damaged distribution transformer (400KVA) | 1 | Job | 100 ₹100 Lowest | 149 ₹149 |
| 4.00 | Unloading of damaged distribution transformer (500/630KVA) | 1 | Job | 100 ₹100 Lowest | 156 ₹156 |
| 5.00 | Dismantling of transformer for repair of 25 KVA Al. wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 500 ₹500 | 309 ₹309 Lowest |
| 6.00 | Dismantling of transformer for repair of 63 KVA Al. wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 500 ₹500 | 358 ₹358 Lowest |
| 7.00 | Dismantling of transformer for repair of 100 KVA Al. wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 500 ₹500 | 378 ₹378 Lowest |
| 8.00 | Dismantling of transformer for repair of 200/250 KVA Al./Cu.wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 500 ₹500 | 388 ₹388 Lowest |
| 9.00 | Dismantling of transformer for repair of 400 KVA Al./Cu. wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 600 ₹600 | 408 ₹408 Lowest |
| 10.00 | Dismantling of transformer for repair of 500/630 KVA Cu. wound three phase 11/.433 KV Distribution Transformer | 1 | Job | 620 ₹620 | 599 ₹599 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
19 Apr 2023, 6:00 pmClosed
Executive Engineer ED JPDCL Reasi
Hall 301, block II, DC Complex Reasi
two years dealing with similar works and satisfying the eligible criteria for the rate Contract (Turn Key) for Repair/Reclamation of Damaged DTs (11KV/6.6KV/0.44KV) of different capacities viz 25 KVA, 63KVA, 100 KVA, 200/250KVA,400KVA,630KVA FY23-24
2023_PDD_208997_1
eNIT 09 of 2023-24 DT 29.03.2023
Open Tender
Electrical Works
Turn-key
3 days
in Divisional workshop at Seela
As per tender documents
2 documents required · 2 mandatory
₹3,000
Office of Executive Engineer ED JPDCL Reasi
₹2.4 L
Office of Executive Engineer ED JPDCL Reasi
9 May 2023
30 Mar 2023
20 Apr 2023
30 Mar 2023
19 Apr 2023
30 Mar 2023
30 Mar 2023 - 12 Apr 2023
12 Apr 2023
Amount
Unloading of damaged distribution transformer (25/63/100KVA)
Unloading of damaged distribution transformer (200/250KVA)
Unloading of damaged distribution transformer (400KVA)
Unloading of damaged distribution transformer (500/630KVA)
Dismantling of transformer for repair of 25 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Dismantling of transformer for repair of 63 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Dismantling of transformer for repair of 100 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Dismantling of transformer for repair of 200/250 KVA Al./Cu.wound three phase 11/.433 KV Distribution Transformer
Dismantling of transformer for repair of 400 KVA Al./Cu. wound three phase 11/.433 KV Distribution Transformer
Dismantling of transformer for repair of 500/630 KVA Cu. wound three phase 11/.433 KV Distribution Transformer
Reconditioning, Testing and Refitting of LV Coil Aluminium
Reconditioning, Testing and Refitting of LV Coil Copper
Supply, Winding, Testing and Fitting of LV Leg Coil Aluminium
Supply, Winding, Testing and Fitting of LV Leg Coil Copper
Reconditioning, Testing and Refitting of HV Coil Aluminium(25/63KVA)
Reconditioning, Testing and Refitting of HV Coil Aluminium(100KVA)
Reconditioning, Testing and Refitting of HV Coil Aluminium(200/250/400KVA)
Reconditioning, Testing and Refitting of HV Coil Copper(200/250/400KVA)
Reconditioning, Testing and Refitting of HV Coil Copper(500/630KVA)
Supply, Winding, Testing and Fitting of HV Leg Coil Aluminium(25/63KVA)
Supply, Winding, Testing and Fitting of HV Leg Coil Aluminium(100KVA)
Supply, Winding, Testing and Fitting of HV Leg Coil Aluminium(200/250/400KVA)
Supply, Winding, Testing and Fitting of HV Leg Coil Copper(200/250/400KVA)
Supply, Winding, Testing and Fitting of HV Leg Coil Copper(500/630KVA)
Supply of HT Bushings
Supply of HT Bush Rods
Supply of LV Bushes for M12 Rod
Supply of LV Bushes for M20 Rod
Supply of LV Bushes for M30 Rod
Supply LV Brass Bush Rod 12MM
Supply LV Brass Bush Rod 20MM
Supply LV Brass Bush Rod 30MM
Reassembling of transformer, providing & fixing of all sundry material for 25 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Reassembling of transformer, providing & fixing of all sundry material for 63 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Reassembling of transformer, providing & fixing of all sundry material for 100 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Reassembling of transformer, providing & fixing of all sundry material for 200/250 KVA Al./Cu.wound three phase 11/.433 KV Distribution Transformer
Reassembling of transformer, providing & fixing of all sundry material for 400 KVA Al./Cu. wound three phase 11/.433 KV Distribution Transformer
Reassembling of transformer, providing & fixing of all sundry material for 500/630 KVA Cu. wound three phase 11/.433 KV Distribution Transformer
Supply and replacement of Gaskets of different sizes
Supply and Filling of Fresh Transformer Oil
Draining, Filteration and Refilling of Transformer Oil in repaired Transformers
Supply and Replacement of Oil Drain Valve
Welding of Transformer Tank for Oil Leakages If Any
Heat treatment and testing for 25 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Heat treatment and testing for 63 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Heat treatment and testing for 100 KVA Al. wound three phase 11/.433 KV Distribution Transformer
Heat treatment and testing for 200/250 KVA Al./Cu.wound three phase 11/.433 KV Distribution Transformer
Heat treatment and testing for 400 KVA Al./Cu. wound three phase 11/.433 KV Distribution Transformer
Heat treatment and Testing for 500/630 KVA Cu. wound three phase 11/.433 KV Distribution Transformer
Painting Charges For 25KVA,63KVA Distribution Transformers
Painting Charges For 100KVA Distribution Transformers
Painting Charges For 200/250KVA Distribution Transformers
Painting Charges For 400KVA Distribution Transformers
Painting Charges For 500/630KVA Distribution Transformers
Loading of Repaired distribution transformers for transportation for (25/63/100 KVA)
Loading of Repaired distribution transformers for transportation for (200/250 KVA)
Loading of Repaired distribution transformers for transportation for (400 KVA)
Loading of Repaired distribution transformers for transportation for (500/630 KVA)
Writeback of Aluminium Scrap
Writeback of Copper Scrap
Writeback of Burnt Out Oil
Writeback of damaged/burnt-out Bush rods (brass)
MAHALAXMI TRANSFORMER INDUSTRY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tendernotice_2.pdf
PDF • 0.68 MB
BOQ_558516.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .