Loading…
Loading…
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
16 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
GEN.ADMN.
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Please follow GCC-April-2022 for Annexure-VIB. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. [NOTE: Failing of submission of Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet shall be liable for rejection.] [NOTE: Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated] through TRACES of Income Tax Department of India.]
Panel Interlocking OR Route Relay Interlocking OR Electronic Interlocking OR IBH OR Automatic Signaling OR LC Gate Interlocking to be considered as similar nature of work for the instant tender work.
35 conditions · 10 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
All documents in support of fulfillment of eligibility criteria with respect to completion of similar nature of work for Technical Eligibility Criteria and Total contract value for Financial Eligibility Criteria should be submitted/ uploaded online in the website with scanned copy at the time of tender bidding with details showing in Annexure I, IV. No post tender communication, in any form will be made or entertained, after opening of tenders, in this regard. Railways may however call for the originals of the credentials for verification or any clarifications/confirmations on the contents of the documents submitted. Eligibility of tenderers shall be decided solely of the basis of the documents submitted along with the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance for finalization of the tender.
Payment through Letter of Credit is applicable for this tender as per Railway Board's letter no 2017/ACII/9/10 Pt I dated 20.02.2018 & 2018/CE-I/CT/9 dt. 04.06.2018 (Annexure B & C attached).
INSTRUCTION TO BIDDERS: A] The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of his obligations or liabilities hereunder nor will it affect any rights of the railway there under. B] In case of any wrong information submitted by tenderer, the contract shall be terminated, Earnest Money Deposit [EMD], performance Guarantee [PG] and Security Deposit [SD] of contract forfeited and agency barred for doing business on entire Indian Railways for 5[five] years.
Shramik kalyan Contractor[s] are requested to get themselves registered on Railways Shramik kalian portal at www.shramikkalyan.indianrailways.gov.in after issuance of letter of acceptance.
GST has been considered during assessment of this instant tender.
Contractor(s)/ Bidders are requested to refer to Clause 46A of Indian Railways Standard General Conditions of Contract'2022 with up to date correction slip for Price Variation Clause (PVC) in works contract. Item no 46A.1 of GCC 2022: Price Variation Clause (PVC) shall be applicable only in tender having advertised value above Rs. 2 Crores. [Authority: Executive Director/Civil Engineering(G), Railway Board's letter No.2022/CE- I/CT/GCC-2022/Policy dated 14.07.2022]
For further details related to 'Bid Security' Bidders are requested to please connect para no 23 of the tender documents.
Bidders are requested to refer to para no 9 of tender document [Para 41 & 42 of Part II Standard General Conditions of Contract for "Variations in extent of Contract" of GCC 2022]
In case Agency desires submission of Bid Security in the form of Bank Guarantee, then please refer to para no 23(3) of Instruction to Tenderers for e-tenders, chapter I for further guidance. [Clause 5.0 of Part I of GCC 2022]
Bidders may also upload any relevant document as deemed fit.
All documents in support of fulfillment of eligibility criteria with respect to completion of similar nature of work for Technical Eligibility Criteria and Total contract value for Financial Eligibility Criteria should be submitted/ uploaded online in the website with scanned copy at the time of tender bidding with details showing in Annexure I, IV. No post tender communication, in any form will be made or entertained, after opening of tenders, in this regard. Railways may however call for the originals of the credentials for verification or any clarifications/confirmations on the contents of the documents submitted. Eligibility of tenderers shall be decided solely of the basis of the documents submitted along with the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance for finalization of the tender.
Payment through Letter of Credit is applicable for this tender as per Railway Board's letter no 2017/ACII/9/10 Pt I dated 20.02.2018 & 2018/CE-I/CT/9 dt. 04.06.2018 (Annexure B & C attached).
INSTRUCTION TO BIDDERS: A] The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of his obligations or liabilities hereunder nor will it affect any rights of the railway there under. B] In case of any wrong information submitted by tenderer, the contract shall be terminated, Earnest Money Deposit [EMD], performance Guarantee [PG] and Security Deposit [SD] of contract forfeited and agency barred for doing business on entire Indian Railways for 5[five] years.
Shramik kalyan Contractor[s] are requested to get themselves registered on Railways Shramik kalian portal at www.shramikkalyan.indianrailways.gov.in after issuance of letter of acceptance.
GST has been considered during assessment of this instant tender.
Contractor(s)/ Bidders are requested to refer to Clause 46A of Indian Railways Standard General Conditions of Contract'2022 with up to date correction slip for Price Variation Clause (PVC) in works contract. Item no 46A.1 of GCC 2022: Price Variation Clause (PVC) shall be applicable only in tender having advertised value above Rs. 2 Crores. [Authority: Executive Director/Civil Engineering(G), Railway Board's letter No.2022/CE- I/CT/GCC-2022/Policy dated 14.07.2022]
For further details related to 'Bid Security' Bidders are requested to please connect para no 23 of the tender documents.
Bidders are requested to refer to para no 9 of tender document [Para 41 & 42 of Part II Standard General Conditions of Contract for "Variations in extent of Contract" of GCC 2022]
In case Agency desires submission of Bid Security in the form of Bank Guarantee, then please refer to para no 23(3) of Instruction to Tenderers for e-tenders, chapter I for further guidance. [Clause 5.0 of Part I of GCC 2022]
Bidders may also upload any relevant document as deemed fit.
S&T work in connection with "construction of ROB compring BOW STRING GIRDER at Bahirkhand At Km 34/4-5 in Seoraphuli (SHE)-Tarakeswer (TAK) line and other ancialiary work in connection with elimination of LC gate No.23/A in Howrah Division Eastern Railway."
DCPM-RSP-SNT-TAK-HWH-2025~ER
DCPM-RSP-SNT-TAK-HWH-2025
Open
Works - General
12 Months
Kolkata, West Bengal
₹0
₹2.4 L
16 Jan 2026
24 Dec 2025
2 Jan 2026
135 items across 1 schedule · ₹1,73,77,120.93 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. | Per Conductor | 1000.00 | 9 | 9,000 |
| 2 | Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. I t c o n s i s t o f following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod - 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of l50x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments t o SEEB (v) Supply of copper lug sleeve for 3/16 cable .Inspection: Consignee | Lot | 20.00 | 15,147 | 3,02,940 |
| 3 | Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. ' | Set | 20.00 | 6,579 | 1,31,580 |
| 4 | Installation, wiring, testing (FAT & SAT) and commissioning of EI System with 'Hot Standby' architecture as supplied above item-100101/2/3. It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital) , installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional. Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/ simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/ directives issued by RDSO from time to time. | Each station/Gate | 1.00 | 5,96,262 | 5,96,262 |
| 5 | Modification/ upgradation, validation and alteration of data logger as per site engineer. This includes changes of NMDL software etc. Also data logger to be interfaced with PI/ EI equipment keeping at relay room. This work includes validation, wiring, etc. For this work necessary wire from relay to tag block & from tag block to data logger and tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms and to be inspected by consignee. | Set | 1.00 | 49,160 | 49,160 |
| 6 | Earthing of EI equipment, relay rack and power equipment etc. to be done along with the supply of all requisite materials, Earthing shall be in the form of Ring Earth conforming to RDSO spec RDSO/SPN/197 Ver.1.0 o r L a t e s t ( w i t h a minimum 10 maintenance free earth electrodes) and as per CSTE/ER/Kolkata's technical circular No.92, using copper rings with earth resistance less than 1 ohm. T h e earthing shall be maintenance free. T h e ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. The copper flat fixed on the wall to the entire breadth of Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B ,C & D class protection shall b e provided for all EI equipment Inspection: Consignee | Station | 1.00 | 2,35,844 | 2,35,844 |
| 7 | Modification /Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines /TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the m a t e r i a l ( I n t e r f a c e cards/re1ays/wiring material/ connectors /fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) j o i n t l y w i t h R a i l w a y s and s a t i s f a c t o r y c o m m i s s i o n i n g . All plans/drawings /circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.Alteration involving modification from 11 up to 20 routes. Here JOB = Per Alteration | Job | 1.00 | 26,99,619 | 26,99,619 |
| 8 | Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents for alteration work. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD). Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways, then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation a n d supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75- micron polyester film for station in Auto CAD. 6 (Six) sets photo copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the l o c a t i o n s , C a b l e t e r m i n a t i o n details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of d e s i g n a n d completion documents f o r a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). | Each station/Gate | 1.00 | 58,797 | 58,797 |
| 9 | "Supply of Electrically Operated Lifting Barrier complete set suitable for 24V DC, supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting of 2 nos. of lifting barrier pedestals, each with 8 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 24vdc of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32 feet length with 2 nos. Stop boards, boom light boxes, MS counter weights and 2 nos. of boom support with motorised boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB and hand generator (24VDC) to operate 2 barriers of 1 set. This includes supply and installation of gate hooter - 1 no and Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC- 1 no with all fixing arrangements. All of the above items including supply of nuts & bolts, foundation as required & supply of cement, civil work materials and etc. Shall be done by the contractor for commissioning. Only 230VAC supply shall be arranged by the railway in nearby relay room. The complete electric lifting barrier set shall confirm to RDSO SPEC NO. RDSO/SPN/208/2012 with latest amendment. Inspection - RDSO. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2 as below- Following spares shall be supplied alongwith each set (02 nos.) of Electric lifting barrier as per requirement of the purchaser i) Steel boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos. vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrench / spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier. Inspection: RDSO" | Set | 1.00 | 4,49,068 | 4,49,068 |
| 10 | Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation (including supply of sand, stone, cement, bolt, plate etc.) for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc. Inspection: Consignee here per gate = per LC gate | Per Gate | 1.00 | 49,506 | 49,506 |
| 11 | "Supply, installation and commissioning of ELB opening ,closing and emergency key operation system as per CSTE/ ER'S Typical circuit diagram No-S.I./TYP/ 0062 Which requires i) Rugged 'NO' press switch(Green) - lNo ii) Rugged 'NO' press switch (Red)- lNo iii) Robust type rotary switch similar to P.I. SM'S key-1 No. iv) Veeder counter to record the count of emergency key operation- lNo v)Superior quality 24VDC pizo buzzer-1 No vi)Good quality 10 mm LED Green- lNo vii)Good quality 10mm LED Red-1 No viii)Good quality 10mm LED yellow-4 No ix)Robust Indication Board with white hylam sheet top (approx dimension 8"x12"x2")- lNo. x)good quality 6"x6" box with transparent cover with locking and sealing arrangement to accomodate emergency rotary switch and veeder counter. Note - contactor has to provide all other items require like flexible wire 16/0.2sq mm for wiring ,casing, capping etc require for installation with one spare for each item from item number -i to viii).Inspection - Consignee." | Numbers | 1.00 | 21,899 | 21,899 |
| 12 | Casting, concreting & curing of foundation (1:3:6) for sliding boom gate as per drawing no. SGW- SDAH /SLIDING GATE FOUNDATION/ 2012 or Latest including supply & fixing of holding down bolts with washers and nuts, MS plates of size 350x350x8 mm, cement, sand, stone chips etc. For foundations required in each set of gate. Note: Balance Sliding Boom Gate will be Supplied By Rly. | Numbers | 1.00 | 53,129 | 53,129 |
| 13 | Installation & commissioning of sliding boom gate. This includes levelling, fixing of sliding boom with fixing of E-type lock, etc. Note : all materials to be supplied by the contractor except sliding boom gate and E- type lock. Note: Balance Sliding Boom Gate will be Supplied By Rly. | Numbers | 1.00 | 7,032 | 7,032 |
| 14 | Supply of magneto / control telephone, annunciator with all accessories and dry cells (2 nos.) For each phone with wooden battery box. This includes supply of magneto telephones with all accessories including supply of 2 nos. Dry cell for each telephone with wooden battery box. (i) SPEC.FOR magneto telephone IRS-TC- 79/2000.AMD-1 OR LATEST.Supply of magneto telephone, desk type, spec. No IRS-TC-79/ 2000 AMDT. 1 or latest. Inspection: by consignee ' | Numbers | 2.00 | 3,509 | 7,018 |
| 15 | Supply of KEY LOCK 'E' type to Drg. No. SA- 3376/M (IRS} Alt.-2 (with latest Alt if any) and KEY to Drg. No. 5-3377/ M (IRS) to ward No. 17 and RDSO specification No. IRS: S- 30/64 (with Amdt. up to date if any).Inspection:RDSO. | Numbers | 6.00 | 1,107 | 6,642 |
| 16 | Earthwork in filling in embankment, guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetations growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract. | cum | 100.00 | 147 | 14,700 |
| 17 | Extra for mechanical compaction of earth/blanketing material filled in embankment with contractor's rollers of suitable capacity, type and size to achieve specified density as per specification, testing as per IS codes incl. cost of water, T&P consumable material and all labour as a complete job. The work is to be executed as per Latest edition of "Guidelines for Earthwork in Railway Projects" issued by RDSO, Lucknow. | cum | 100.00 | 15 | 1,500 |
| 18 | Removal of excavated/ slip earth/ debris/ malba from the site of works to any other place outside Railway land/premises, including all excavations, handling, re- handling, loading, unloading and leading, etc. all labour and material as a complete job. Removal of Earth (all kinds of soils)/ ROCKS, BOULDERS including mud/slush, slipped earth in catch water drains, side drains, over berms in cutting, water way of b r i d g e s , o v e r c o p i n g of toe/breast /retaining walls etc. including crossing of nallah, railway tracks, making/repairing approach roads if required, all lead, lift, ascent, descents, or any other obstruction. Earth spoils to be dumped outside the cutting or railway embankments as per direction of Engineer in charge. | cum | 100.00 | 138 | 13,800 |
| 19 | Supply of Yellow Retro reflective sheet for LC Boom prismatic grade reflective sheets of size 305 x 290 mm one s e t consist 18 pieces. Inspection: Consignee | Set | 2.00 | 1,708 | 3,416 |
| 20 | Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates.Inspection: Consignee | Set | 2.00 | 5,417 | 10,834 |
| 21 | Supply a n d installation o f L E D type table mounting gate control-cum-indication panel of required size as per site engineer and as per signalling plan including supply of wooden table (hard wood) of standard height for mounting of panel, cable entry in panel with 50 mm dia gallant. Note- gate panel should have button operation for gate close & open instead of switch. The switch for signal operation preferably should have 2NC/2RC contact. Make- Deltron or similar. Inspection- Consignee. | Numbers | 1.00 | 15,976 | 15,976 |
| 22 | Installation, wiring and testing of electrical key transmitter for LC gate control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for LC gate control as per yard diagram, approved circuit diagram and specn.no. IRS-S- 21/01(LATEST) AND IRS-5- 23(LATEST), DRG.NO.SA-22601 (ADV)ALT.2. [key combination will be intimated by site engineer]Supply. Inspection : RDSO. | Numbers | 1.00 | 7,044 | 7,044 |
| 23 | Installation, wiring and testing of electrical key transmitter for LC gate control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for LC gate control as per yard diagram, approved circuit diagram and specn.no. IRS-S- 21/01(LATEST) AND IRS-5- 23(LATEST), DRG.NO.SA-22601 (ADV)ALT.2. [key combination will be intimated by site engineer]Execution. | Numbers | 1.00 | 6,672 | 6,672 |
| 24 | Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both of any reputed make are to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on E Rly on location boxes, signal posts, TLJB. This includes lettering/ Numbering of signals, TLJB & Block joints if any, apparatus Cases, gate booms , etc , Description writing , legibly and neatly inside location boxes , relay hut, gate lodge etc. - for LC Gate. Inspection: by Consignee. Here Lot = Lot/Gate | Lot | 1.00 | 6,534.52 | 6,534.52 |
| 25 | Supply, Installation and Commissioning of Power supply arrangement for interlocking LC gate (without solar panel) with SMPS based inverters GSM module with required software ( to raise alarm in the form of SMS to the concerned staff in regular interval until the defect in any module is rectified duly following the escalation matrix. Alarm to be raised if any module in the system fails to give output. The system should be housed in 19" SS 12UMax Rack with back panel Mother Board with power connectors with AC mains MCB power connector, voltage monitoring Relay with delay timer (UV,OV, No/Nc) DPM meter to read I/P voltage/current as required of following modules and as per block diagram and Annexure attached | Numbers | 1.00 | 6,65,520 | 6,65,520 |
| 26 | HP Laser Mono Computer Printers for A4 paper size hp( HP Leser Jet or Similar) HP LaserJet Enterprise M407dn with 5 year warranty | Numbers | 1.00 | 57,997 | 57,997 |
| 27 | Supply of Failure Analysis System (FAS) with Fault Analysis Software (Datalogger Analyser) consisting of a PC (Make- Dell /HP or Equivalent) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The minimum specification should be as given core i7 or higher version processor (speed 3.2 GHZ, 4 MB cache memory), 8 GB RAM,2TB HDD or Higher, Two front and four rear USB port,1 Serial & 1 Parallel Port,1VGA Port,21" LED Colour Monitor (HP/DELL or equivalent) or Bigger Size, Sound Card with Speaker,1000 MBPS Network Card, Keyboard, Optical Mouse,10/100 T Lan Card, Combo Drive, Microsoft Windows 10 Licensed OS with Licensed (Antivirus, MS Office etc.),UPS 750 VA with 30 Minutes minimum backup(APC/ Microtek or Equivalent) , Laserjet Printer(H P Pro 1108 or superior). Inspection: Consignee | Numbers | 2.00 | 1,16,554 | 2,33,108 |
| 28 | Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]. Note: - wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. | Per Relay | 20.00 | 270 | 5,400 |
| 29 | Supply of fuse i n s e r t s cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: - RDSO.Fuse, non- deteriorating(2A) type, cylindrical(IRS-S- 78/92) [quantity as per site requirement] | Numbers | 50.00 | 61 | 3,050 |
| 30 | Supply o f P B T A R A terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only. Inspection: RDSO.1 WAY,DRG NO.23741A, ALT-4. | Numbers | 10.00 | 78 | 780 |
| 31 | Supply o f P B T A R A terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only. Inspection: RDSO.6 WAY, DRG.NO.23756, ALT-3. | Numbers | 40.00 | 485 | 19,400 |
| 32 | Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No. IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this u n i t s h a l l be "ABCDF". Inspection authority:- RDSO | Numbers | 10.00 | 4,100.03 | 41,000.3 |
| 33 | Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No. IRS: 5-34 & S-23with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDEG". Inspection authority:- RDSO | Numbers | 10.00 | 6,274.04 | 62,740.4 |
| 34 | Q-Series LED ECR (Universal Type i.e. QECX- 61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:94 1A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDHK".Inspection authority:- RDSO | Numbers | 20.00 | 5,389.28 | 1,07,785.6 |
| 35 | "Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn. No.IRS: S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO" | Numbers | 20.00 | 4,218.7 | 84,374 |
| 36 | "Q-Series Neutral Line Relay(QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@45"44@ 5- 23 & S 60 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABDEJ"". Inspection authority:- RDSO" | Numbers | 5.00 | 5,491.06 | 27,455.3 |
| 37 | Contactor Unit (QBCA 1 Type), 24 V DC, 2F(HD)/ 4B or 2F(HD)2F-4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS: 5-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit s h a l l b e "BCEJK" o r "DEHJX". Inspection authority:- RDSO | Numbers | 5.00 | 7,656.45 | 38,282.25 |
| 38 | Dismantling of level crossing gates with all accessories as per site engineers. | Numbers | 1.00 | 3,004 | 3,004 |
| 39 | Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I) - 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT(galvanised) of size 35 mm x 6 mm (SPEC. NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE /ER'S DRG.NO.S&T-1/2007. Inspection: - BY RITES [for value of material above Rs. 5.O lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | Numbers | 20.00 | 1,496 | 29,920 |
| 40 | Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest). Inspection : by consignee. | Numbers | 20.00 | 911 | 18,220 |
| 41 | Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. | Numbers | 20.00 | 1,161 | 23,220 |
| 42 | Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. | Numbers | 20.00 | 571 | 11,420 |
| 43 | Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF F I R M S FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy | Numbers | 10.00 | 13,916 | 1,39,160 |
| 44 | Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces- both inside and outside. | Numbers | 10.00 | 3,532 | 35,320 |
| 45 | Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. | Numbers | 10.00 | 4,830 | 48,300 |
| 46 | Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | Sqm | 5.00 | 5,370 | 26,850 |
| 47 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C- 40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4" of 1:2:4 concreting s h o u l d b e done. Note:-(b-1) payment wifi be made as per actual work done on pro-rata basis, if required depth is not available a t site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | cum | 2000.00 | 245 | 4,90,000 |
| 48 | Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to O.6 Mtrs wide and back filling after placing of DWC / RCC/GI pipe. (Placing of DWC/ RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. F o r track crossing, RDSO sketch No. SDO/CABLE LAYING/ 009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. | cum | 200.00 | 278 | 55,600 |
| 49 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | RM | 2000.00 | 5 | 10,000 |
| 50 | Placing of DWC HDPE /RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. ' | RM | 1000.00 | 31 | 31,000 |
| 51 | Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | cum | 20.00 | 3,596 | 71,920 |
| 52 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments. Inspection: (i).Inspection: Consignee .Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). .Inspection: Consignee " | Numbers | 1000.00 | 55 | 55,000 |
| 53 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments. Inspection: (i).Inspection: ConsigneeSupply of End plate 2.5mm/0.091 in thick as per site requirement. .Inspection: Consignee " | Numbers | 200.00 | 10 | 2,000 |
| 54 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments. Inspection: (i).Inspection: ConsigneeSupply of End Stopper 10mm/0.0394 in width as per site requirement..Inspection: Consignee " | Numbers | 200.00 | 10 | 2,000 |
| 55 | Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments. Inspection: (i).Inspection: ConsigneeSupply of Markers strip..Inspection: Consignee | Numbers | 500.00 | 16 | 8,000 |
| 56 | "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signalling) With latest amendments. Inspection: (i).Inspection: ConsigneeSupply of shooting link (jumper) (part no - 283- 402 or similar) , suitable for 0.2 to 16 sqmm terminal block 283-901 or similar. .Inspection: Consignee " | Numbers | 500.00 | 2 | 1,000 |
| 57 | "Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside) " | Numbers | 10.00 | 260 | 2,600 |
| 58 | Disconnection & Reconnection of All Signalling Equipments like Cables/TLJB/Point Machine G.Fitting/Point JB/BPAC Track Device etc. immediate before and after the work during block period. This Includes cost of the Releasing of Signalling equipmets and Reconnection of the same after the work. This includes 1 Fitter, 1 Black Smith, 1 Hammer Man, 1Cable Jointer, 1 Bonding fitter, 4 Khalasis. | Day | 90.00 | 3,575.85 | 3,21,826.5 |
| 59 | Supply of colour light signal post 5.6 mtr and ladder 5.5 mtr with bases for ladder & post as per RDSO SPEC. NO. IRS:S-6-81 (or latest) and DRG. NO. SA-23156 (ADV), ALT- 1 (OR LATEST). CLS base as per DRG. NO. S-2011/M (OR LATEST). Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | Numbers | 3.00 | 15,707 | 47,121 |
| 60 | Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23003/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/ SPN/ 151/1997 OR LATEST. Afl drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water.Supply. Inspection: (i)RDSO/RITES if value of item i n work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | Numbers | 3.00 | 26,583 | 79,749 |
| 61 | Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23003/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/ SPN/ 151/1997 OR LATEST. Afl drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water Execution | Numbers | 3.00 | 1,658 | 4,974 |
| 62 | "Installation, erection and wiring of junction type route indicator [LED type] this include supply of non metallic FRP junction type route indicator for Railway Signalling suitable for RE Area without lamp. Lenses, signal transformer as per RDSO SPEC. NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP material as per RDSO SPEC. NO. RDSO/SPN/151/ 1997 OR LATEST. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to LED type. Note: installation, erection & wiring of signalling unit includes LED signal, lighting unit including current regulator. This also includes protection of unit from rain water Supply of 2 WAY AS PER RDSO DRG. NO. SA- 23402 ( A D V ) / ALT.2 Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 1.00 | 43,270 | 43,270 |
| 63 | Installation, erection and wiring of junction type route indicator [LED type] this include supply of non metallic FRP junction type route indicator for Railway Signalling suitable for RE Area without lamp. Lenses, signal transformer as per RDSO SPEC. NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP material as per RDSO SPEC. NO. RDSO/SPN/151/ 1997 OR LATEST. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to LED type. Note: installation, erection & wiring of signalling unit includes LED signal, lighting unit including current regulator. This also includes protection of unit from rain water Execution of 2 WAY AS PER RDSO DRG. NO. SA- 23402 (ADV)/ ALT.2 | Numbers | 1.00 | 1,203 | 1,203 |
| 64 | "Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit as per technical specification. This includes supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer a s p e r RDSO D R G NO. SA- 23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type.Supply.Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Numbers | 2.00 | 6,782 | 13,564 |
| 65 | Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit as per technical specification. This includes supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer a s p e r RDSO D R G NO. SA- 23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type Execution | Numbers | 2.00 | 502 | 1,004 |
| 66 | Casting, concreting and curing of foundation for Shunt signal including cost o f a l l materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanised bolts & nuts with washers, cement, sand, stone chips, etc. As per DRG. NO SK/5/95/NKG. | Numbers | 2.00 | 4,087 | 8,174 |
| 67 | Releasing of existing tail cables and drawl of new tail cables for colour light signals up to four aspects with or without route indicator, post type shunt signal and calling signals. Termination of new tail cables and wiring using wire PVC 3/0.75 mm copper as per latest RDSO spec. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals [Wire PVC 3/0.75 mm copper, paints and all other miscellaneous materials shall be supplied by the contractor. Wire to be procured from RDSO's approved source only]. Inspection- consignee. | Numbers | 3.00 | 3,065 | 9,195 |
| 68 | Dismantling of existing main signal including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part. | Numbers | 2.00 | 1,218 | 2,436 |
| 69 | Dismantling of existing Signal Foundation (upto ground level by hydraulic breaker). | Numbers | 2.00 | 2,212 | 4,424 |
| 70 | Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area. Inspection: Consignee. | Numbers | 2.00 | 3,502 | 7,004 |
| 71 | Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH /SK-1386 and as per standard practice.Inspection: Consignee | Numbers | 4.00 | 373 | 1,492 |
| 72 | Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). | Numbers | 2.00 | 8,065 | 16,130 |
| 73 | Electronic LC gate telephone systems with voice recorder as per RDSO SPEC.NO.RDSO /SPN/TC/ 51/2011 R E V 4.0.Inspection- consignee. Material to be supplied from RDSO's approved source only with 03(three) years full warranty. Note: - 1) the date of manufacture of the item should be of current year at the time of supply to railway stores. 2)Installation by OEM.Supply of Master telephone with voice recording facility. Inspection : Consignee. | Numbers | 1.00 | 49,971 | 49,971 |
| 74 | Electronic LC gate telephone systems with voice recorder as per RDSO SPEC.NO.RDSO /SPN/TC/ 51/2011 R E V 4.0.Inspection- consignee. Material to be supplied from RDSO's approved source only with 03(three) years full warranty. Note: - 1) the date of manufacture of the item should be of current year at the time of supply to railway stores. 2)Installation by OEM Supply of Gate (slave)te1ephone. Inspection : Consignee. | Numbers | 1.00 | 5,210 | 5,210 |
| 75 | Supply of Limit Switch Set for boom lock proving. The material will be as per RDSO Specn. No.RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest. Inspection: Consignee. | Set | 5.00 | 1,302 | 6,510 |
| 76 | Gear box assembly with clutch Assembly for ELB confirming to RDSO spec. No> RDSO/SPN/208/2012 Ver. 2.0 Maker's | Numbers | 5.00 | 31,500 | 1,57,500 |
| 77 | SUPPLY & INSTALLATION OF ELEC. LIFTING BARRIER GATE SPARE PARTS AS PER RDSO SPECIFICATION RDSO/SPN/208/2012 VER. 2.0 OR LATEST. AND MATERIALS SHOULD PROCURED ON RDSO APPROVED FIRM OF M/s URBAN MAKE OR SIMILAR. INSPECTION : AUTHORISE REPRESENTATIVE OF Sr.DSTE/HWH. ROTARY SWITCH OF GATE PANEL | Numbers | 5.00 | 930.95 | 4,654.75 |
| 78 | Supply of Cable Fault locator asper specification in section-H.Make: RadiodetectionR(1205CXB) or similar.INSPECTION BY RITES. | Numbers | 1.00 | 4,90,000 | 4,90,000 |
| 79 | Supply of cable route tracerwith Integrated GPS and Bluetooth, Live GPS datatransfer with Mobile App,through BT, User configurablefrequency and Current directionindication & 10W Transmitterwith minimum 500mA outputcurrent and 90V visible ondisplay, with rechargeableBattery. Specification as persection H. Make: Radiodetection(RD8200G) or similar. 3 yearsOEM warranty. INSPECTION BYRITES. | Numbers | 1.00 | 6,11,240 | 6,11,240 |
| 80 | SUPPLY & INSTALLATION OF ELEC. LIFTING BARRIER GATE SPARE PARTS AS PER RDSO SPECIFICATION RDSO/SPN/208/2012 VER. 2.0 OR LATEST. AND MATERIALS SHOULD PROCURED ON RDSO APPROVED FIRM OF M/s URBAN MAKE OR SIMILAR. INSPECTION : AUTHORISE REPRESENTATIVE OF S&T/GSU/HWH. . ELB BOOM 'A' SECTION | Numbers | 2.00 | 7,864.03 | 15,728.06 |
| 81 | SUPPLY & INSTALLATION OF ELEC. LIFTING BARRIER GATE SPARE PARTS AS PER RDSO SPECIFICATION RDSO/SPN/208/2012 VER. 2.0 OR LATEST. AND MATERIALS SHOULD PROCURED ON RDSO APPROVED FIRM OF M/s URBAN MAKE OR SIMILAR. INSPECTION : AUTHORISE REPRESENTATIVE OF S&T/GSU/HWH ELB BOOM 'B' SECTION | Numbers | 2.00 | 5,948.49 | 11,896.98 |
| 82 | SUPPLY & INSTALLATION OF ELEC. LIFTING BARRIER GATE SPARE PARTS AS PER RDSO SPECIFICATION RDSO/SPN/208/2012 VER. 2.0 OR LATEST. AND MATERIALS SHOULD PROCURED ON RDSO APPROVED FIRM OF M/s URBAN MAKE OR SIMILAR. INSPECTION : AUTHORISE REPRESENTATIVE OF S&T/GSU/HWH. ELB BOOM 'C' SECTION | Numbers | 2.00 | 6,194.68 | 12,389.36 |
| 83 | SUPPLY & INSTALLATION OF ELEC. LIFTING BARRIER GATE SPARE PARTS AS PER RDSO SPECIFICATION RDSO/SPN/208/2012 VER. 2.0 OR LATEST. AND MATERIALS SHOULD PROCURED ON RDSO APPROVED FIRM OF M/s URBAN MAKE OR SIMILAR. INSPECTION : AUTHORISE REPRESENTATIVE OFS&T/GSU/HWH. ELB BOOM 'D' SECTION | Numbers | 2.00 | 6,609.15 | 13,218.3 |
| 84 | SUPPLY OF FLUKE 4 DIGIT BACKLIT LCD HAND HELD TRUE RMS CLAMP METER ( FLUKE 376 ) PRODUCT ID 5116877- 69455604014 | Numbers | 2.00 | 78,930 | 1,57,860 |
| 85 | VF Transformer 1120: 600 Ohms (Rack Mountable type as per RDSo Spec. No. IRS- TC-22/2021 Ver. 1.0 or Latest | Numbers | 2.00 | 1,105 | 2,210 |
| 86 | Metravi HandHeld 100 KHz Digital Multi Meter- Brand-Metravi and %u201C Specification other Terms and conditions are as per GeM Contact No.GEMC- 511687751411817 | Numbers | 2.00 | 10,492 | 20,984 |
| 87 | Supply of sliding boom gate as per eastern railway signal workshop / Howrah's drawing no. BSA/29/730, BSA/29/731 & BSA/29/737 or Latest. This includes supply of 8 nos. E-type lock with key as per IRS SPEC. NO. IRS-5-30/64 with latest amendment. Key lock 'e' type as per drawing no. SA-3376/ M, 3377/M with latest amendment or Latest. Ward no. To be decided by the site engineer. 'E' type lock to be on MS plate as mentioned in the drawing. Inspection: by rites [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | Numbers | 1.00 | 1,97,415 | 1,97,415 |
| 88 | Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. {items to be procured through Storee} Inspection: RDSO RED Aspect | Numbers | 4.00 | 8,362 | 33,448 |
| 89 | Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. {items to be procured through Storee} Inspection: RDSO YELLOW Aspect | Numbers | 4.00 | 8,387 | 33,548 |
| 90 | Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. {items to be procured through Storee} Inspection: RDSO GREEN Aspect | Numbers | 2.00 | 9,438 | 18,876 |
| 91 | Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. {items to be procured through Storee} Inspection: RDSO LED for Route Aspect | Numbers | 10.00 | 5,478 | 54,780 |
| 92 | Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. {items to be procured through Storee} Inspection: RDSO LED for Shunt Signal Aspect | Numbers | 6.00 | 5,675 | 34,050 |
| 93 | Construction and fixing of RCC cable duct ( pre-cast) for cable laying in station yard (this includes laying of cable through cable duct as per site engineer) as per drawing no.ds/35/2012 | Metre | 800.00 | 3,742 | 29,93,600 |
| 94 | Supply of Double Wall Corrugated (DWC) - HDPE pipe/duct of size 200 mm outer dia, R 175 mm inner dia. It includes supply of Double Wall Corrugated -H DPE pipe/duct as per RDSO Specn. No. RDSO/ SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. | Metre | 200.00 | 397 | 79,400 |
| 95 | Placing of DWC HDPE /RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | RM | 200.00 | 31 | 6,200 |
| 96 | Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or S i m i l a r o f r e p u t e d brand. Inspection: Consignee | Numbers | 1.00 | 12,886 | 12,886 |
| 97 | "Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming t o BRS:939A & 966(Appendix F2) and RDSO Spec No. IRS:S 34, S-23 with amdt. upto date as applicable or latest with latest amdt. or latest. The interlocking code for this unit shall be ""FGHKX"". Inspection authority:- RDSO " | Numbers | 5.00 | 3,815 | 19,075 |
| 98 | Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: 5-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 8 0 A H Battery. Inspection: RDSO | Numbers | 5.00 | 4,894 | 24,470 |
| 99 | Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA- 20161-66/ M or latest. Inspection: Consignee | Numbers | 5.00 | 171 | 855 |
| 100 | Installation wiring, testing and commissioning of single rail dc track circuit (SHORT LENGTH TRACK CIRCUIT UPTO 200 MTS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. | Per Track Circuit | 5.00 | 3,244 | 16,220 |
| 101 | Supply of Track Lead Junction Box(TLJB) made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows:(a) TAB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TAB shall have two bakelite terminal block fitted horizontally : each bakelite terminal block shall have t w o nickel chrome plate M 1 0 brass terminal, 50mm long. Alongwith each TAB , nickel chrome plated brass links(two nos.Of adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TAB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength t o b e supplied alongwith TAB.Inspection: (i) RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. | Numbers | 10.00 | 3,564 | 35,640 |
| 102 | Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee | Numbers | 10.00 | 1,316 | 13,160 |
| 103 | Supply of B Type Choke as per RDSO Specn. No.IRS: S-65/83 (Airind. 1) or latest. Inspection: RDSO. | Numbers | 5.00 | 5,151 | 25,755 |
| 104 | "Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. 5- 69/M. Inspection: Consignee." | Numbers | 100.00 | 4 | 400 |
| 105 | Supply of GI wire 8 SWG (4mm dia) suitable for track c i r c u i t r a i l bonding. Inspection: Consignee | Numbers | 100.00 | 12 | 1,200 |
| 106 | Provision/Installation of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia. holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee. | Numbers | 100.00 | 180 | 18,000 |
| 107 | "Supply & installation of polymer positive temperature coefficient device (PPTC) resettable fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHE M, BOURNS, LITTLE FUSE, FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs. "". Inspection: Consignee." | Numbers | 50.00 | 79 | 3,950 |
| 108 | "Supply & installation of 'C' class surge protection arrangement at feed end DC Track Ckt Specn no. As follows: - voltage 230 V AC rated voltage 350V AC DIS. CAP 10KA TO 20 KA TIME 100 MILI second protection 1.2V degree protection IP.20 TEC-61643-1. Inspection : by consignee." | Numbers | 20.00 | 1,346 | 26,920 |
| 109 | Supply of unchanged Low Maintenance Lead Acid (LMLA) secondary c e l l , shelf m o u n t i n g type conforming to RDSO Specn.No. IRS:5-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO 2V, 80 AH | Numbers | 15.00 | 3,574 | 53,610 |
| 110 | Charging of lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity a c i d s h o u l d be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery t o b e kept o n wooden rack. Inspection: Consignee. 2V 80AH | Numbers | 15.00 | 367 | 5,505 |
| 111 | Repair of pucca roads to original state in level crossing area after cable laying. | Metre | 500.00 | 256 | 1,28,000 |
| 112 | Removal of PRC Sleeper in the way of cable route. | Numbers | 500.00 | 63 | 31,500 |
| 113 | "Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per siteengineer for placing and for crossing of signalling /telecom.Cable through HDPE pipe at bridges/ culverts/ track crossing/pucca road crossing, boring trench shall be minimum 03(three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum- 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer." | Metre | 1500.00 | 1,758 | 26,37,000 |
| 114 | Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re- arrangement of DC-DC converters by OEM of IPS. Alteration Work | Each station/Gate | 1.00 | 69,824 | 69,824 |
| 115 | Preparation of new Signal Interlocking Plan (SIP)based on approvedEnigineering Scale Plan(ESP). Station more than 8lines. | Station | 1.00 | 74,956.52 | 74,956.52 |
| 116 | Alteration in RCC. Thecontactor shall supply theRCC paper print (02 copies)for approval of Railway . Ifcorrections are shown inRCC, fresh paper print (2copies) shall be given bythe Contractorincorporating the changesmade. The final RCC shallbe submitted in tracingpaper (01 copy) forapproval as Completion.Thereafter the scannedcopy of approved RCC (intracing) and the AutoCADfile version to be shared assoft copy with Railway. | Per Route | 20.00 | 655.2 | 13,104 |
| 117 | Preparation and Supply of station working roule(SWR) in English based onapproved ESP, SIP andprovisions of GR/SR, IRSEMand other Railway policiesissued from time to time.Note: The contactor shallsupply station workingroule paper (02 copy). andMS office word version tobe shared as soft copy withRailway. SWR to beprepared by Ex. TI/Ex.SSE/JE(Sig)/ Ex. SSE/JE(Drg)" | Station | 1.00 | 11,134.31 | 11,134.31 |
| 118 | Preparation and Supply of station working rouleDiagram (SWRD)/Gateworking Rule Giagram(GWRD) based onapproved SignalInterlocking Plan (SIP).Note:- The contactor shallsupply tentativeSWRD/GWRD in paper print(04 copies) for approval ofRailway along with AutoCadfile. After getting approvalon tentative SWRD, thefinal SWRD/GWRD shall besubmitted in tracing paper(01 copy). Thereafter thescanned copy of approvedSWRD (in tracing) and theAutoCAD file final versionto be shared as soft copywith Railway in a suitablestorage device.Station, LC Gate, IBS & ABS more than08 lines. | Station | 1.00 | 32,562.62 | 32,562.62 |
| 119 | Alteration/modification i n t h e existing location boxes (full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | Numbers | 5.00 | 2,782 | 13,910 |
| 120 | Dismantling of location box / RCC Goomty including all its accessories & concrete foundation. | Numbers | 5.00 | 651 | 3,255 |
| 121 | Shifting/lifting of location box to facilitate earthwork of Engg/Con.This includes filling with sand and plastering inside location box. | Numbers | 5.00 | 2,759 | 13,795 |
| 122 | "LOADING , UNLOADING AND TRANSPORTATION OF MATERIALS INCLUDING CABLES, LOCATION BOXES AND MISCLLANEOUS / RELEASED ITEMS REQUIRED FROM VARIOUS PLACES IN 9 MT TRUCK TO THE RAILWAY STORE AS PER SITE ENGINEER. A) TRANSPORTATION " | Kilometre | 1000.00 | 38.05 | 38,050 |
| 123 | "LOADING , UNLOADING AND TRANSPORTATION OF MATERIALS INCLUDING CABLES, LOCATION BOXES AND MISCLLANEOUS/RELEASED ITEMS REQUIRED FROM VARIOUS PLACES IN 9 MT TRUCK TO THE RAILWAY STORE AS PER SITE. B) LOADING AND UNLOADING" here JOB = TRIP | Job | 10.00 | 1,699.14 | 16,991.4 |
| 124 | Marking of all circuit particulars nearterminals on terminal board/ rack inapparatus case, junction boxes andnomenclature relays, fuses, equipmentsas per approved drawing. | Station | 1.00 | 19,384.6 | 19,384.6 |
| 125 | Miscellaneous arrangement for NI period comprising of Provision of water-proof temporary goomty/tent at bothside of the station yard and at central PI/EI Station. Numbers of Goomty as per Site r e q u i r e m e n t . Each goomties to be furnished with one iron table, six chairs,emergency light and mosquitorepellent caps for NI staff, PA system, crow bar men for operating point and men for supplying water to tents. | Station | 2.00 | 1,10,602.06 | 2,21,204.12 |
| 126 | "Supply of 1 x 10 Sq.mm. {Red/Black/Green} multi strand copper power wire as per IS:694:20 10 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per R D S O Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Metre | 500.00 | 119 | 59,500 |
| 127 | "Supp1y of 1 x 16 Sq.mm. {Red/Black/Green} multi strand copper power wire as per IS:694:20 10 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/ km and test parameters as per RDSO Specn. No.IRS: S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Metre | 500.00 | 131 | 65,500 |
| 128 | "Supply of 1 a 25 Sq.mm. {Red/B1aek) multi strand copper power wire as per IS:694: 2010 or latest, 196 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn. No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more t h a n 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | Metre | 100.00 | 277 | 27,700 |
| 129 | Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] | Numbers | 2.00 | 24,449 | 48,898 |
| 130 | Supply of Split DWC Pipe in thecable Trench parallel to track oras per Site and approved cableroute plan. Split DWC pipeshaving non flame propagationand Anti Roddent properties(minimum outer dia 250 mm &minimum Inner Dia 217 mm)with out socket /coupler as perIS:14930, Pt-II(ISI Marked).Inspection : Consignee | Numbers | 1000.00 | 713.14 | 7,13,140 |
| 131 | Laying & Installation of SplitDWC Pipe in the cable Trenchparallel to track or as per Siteand approved cable route plan.This includes supply of SplitDWC pipes having non flamepropagation and Anti Roddentproperties (minimum outer dia175 mm & minimum Inner Dia148 mm) as per IS:14930, Pt-II(ISI Marked) OR LATEST | Numbers | 1000.00 | 54.84 | 54,840 |
| 132 | Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/ 2012 revision 3 With latest Amdt. | Numbers | 4.00 | 2,185 | 8,740 |
| 133 | Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After joining the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. | Numbers | 4.00 | 956 | 3,824 |
| 134 | Supply of Splice Closure for Optical Fiber Cables (48F) Armoured and Metal free type OFC With screws sealing as per as per TEC/GR/TX/OJC-002/03/APR-2010 or latest, including all miscellaneous items & consumables for fiber splicing, make: 3M/Comscope/R&M/similar, Inspection: Rites.. Inspection:- by consignee. | Numbers | 4.00 | 4,404.51 | 17,618.04 |
| 135 | Jointing, terminating and Splicing of 48 Fibre Optical Fibre Cable and fixing of termination Box/FDF/Placing of joint clousers in pit required at various location including tranportation of all the jointing & terminating materials from railway store to the works site and returning leftover materials to the railway store. The rate should include all jointing materials. | Numbers | 4.00 | 13,347 | 53,388 |
| Schedule total | ₹1,73,77,120.93 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .