Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.5 LAccepted-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PUNJAB | 147001 | ₹93.5 L Quoted ₹96.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹97.8 LRejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | ₹97.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹98.4 LRejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹98.4 L | L3 | Rejected-Finance L3 |
| 4 | L4₹99.1 LRejected-Finance 68 NEW OFFICER S COLONY PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹99.1 L | L4 | Rejected-Finance L4 |
| 5 | L5₹1.0 CrRejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹1.0 Cr | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | Arneja Builders L1 | Vinod Kumar Bajaj L6 | M/S RAJ KUMAR GUPTA L2 | Surindera Kumar Bansal L8 | Buttar Construction Co. L3 | V K CONTRACTOR L7 | Jawandha Enterprises L5 | BHARAT BHUSHAN CONTRACTOR L9 | ANIL KUMAR AND CO L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge | 510 | Sqm | 10 ₹5,100 | 10 ₹5,100 | 12 ₹6,120 | 20 ₹10,200 | 10 ₹5,100 | 18 ₹9,180 | 50 ₹25,500 | 20 ₹10,200 | 10 ₹5,100 |
| 2.00 | Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) complete all as specified and as directed by Engineer-in-Charge. | 40.8 | Cum | 200 ₹8,160 | 100 ₹4,080 | 100 ₹4,080 | 150 ₹6,120 | 145 ₹5,916 | 115 ₹4,692 | 250 ₹10,200 | 150 ₹6,120 | 150 ₹6,120 |
| 3.00 | Material and labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge. | 510 | Sqm | 5 ₹2,550 | 10 ₹5,100 | 8 ₹4,080 | 20 ₹10,200 | 10 ₹5,100 | 15 ₹7,650 | 50 ₹25,500 | 20 ₹10,200 | 10 ₹5,100 |
| 4.00 | Material and labour for cement concrete 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 45mm to maintain slope of 1:100, complete all as specified and as directed by Engineer-in-Charge. | 25.5 | Cum | 4,000 ₹1.0 L | 4,000 ₹1.0 L | 4,500 ₹1.1 L | 4,500 ₹1.1 L | 4,050 ₹1.0 L | 4,800 ₹1.2 L | 3,500 ₹89,250 | 5,000 ₹1.3 L | 4,200 ₹1.1 L |
| 5.00 | Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge | 300 | RM | 70 ₹21,000 | 100 ₹30,000 | 100 ₹30,000 | 90 ₹27,000 | 40 ₹12,000 | 110 ₹33,000 | 70 ₹21,000 | 90 ₹27,000 | 50 ₹15,000 |
| 6.00 | Material and labour for laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer 0.40 Itr/sqm by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70-160 cps Over the coat, the layered APP membrane shall be laid using butane torch and sealing all joints etc complete as per standard practice and as per manufacturers instructions complete all as specified and as directed by Engineer-in-charge. | 600 | Sqm | 280 ₹1.7 L | 350 ₹2.1 L | 370 ₹2.2 L | 400 ₹2.4 L | 300 ₹1.8 L | 300 ₹1.8 L | 315 ₹1.9 L | 500 ₹3 L | 300 ₹1.8 L |
| 7.00 | Material and labour for cement concrete tiles with grey cement & no pigments of size. 25 cm x 25 cm and 20 mm thick, machine pressed and cut polished and set jointed and pointed in neat cement slurry laid over and including 15 mm thick screed bed in cement mortar (1:3) and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound as per manufacturers instructions over roof surfaces complete all as specified and as directed by Engineer-in-Charge. | 510 | Sqm | 500 ₹2.5 L | 600 ₹3.1 L | 590 ₹3.0 L | 650 ₹3.3 L | 595 ₹3.0 L | 500 ₹2.5 L | 550 ₹2.8 L | 650 ₹3.3 L | 600 ₹3.1 L |
| 8.00 | Material and labour cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregates as in mud stops, benching and coping etc rounded or chamfered on edges complete all as specified and as directed by Engineer-in-Charge | 6 | Cum | 3,000 ₹18,000 | 4,000 ₹24,000 | 4,000 ₹24,000 | 4,500 ₹27,000 | 3,500 ₹21,000 | 4,000 ₹24,000 | 3,000 ₹18,000 | 4,500 ₹27,000 | 3,500 ₹21,000 |
| 9.00 | Supply and fixing PVC(HDPE) rain water pipes, 150 mm bore, single socketed in any length with rubber ring joints fixed to walls with flat iron clamps of size 25 x 3mm, incluing bolts, washer, nuts etc including taking down existing damaged CI rain water pipe complete all as specified and as directed by Engineer-in-Charge | 135 | RM | 350 ₹47,250 | 400 ₹54,000 | 330 ₹44,550 | 400 ₹54,000 | 450 ₹60,750 | 400 ₹54,000 | 500 ₹67,500 | 400 ₹54,000 | 500 ₹67,500 |
| 10.00 | Supply and fixing in repair PVC (SWR) bends/tees of any radius for 150mm bore pipe complete all as specified and as directed by Engineer-in-charge. | 36 | Each | 150 ₹5,400 | 300 ₹10,800 | 300 ₹10,800 | 290 ₹10,440 | 300 ₹10,800 | 390 ₹14,040 | 200 ₹7,200 | 290 ₹10,440 | 350 ₹12,600 |
Updated dates
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
19 Jan 2026, 6:00 pmClosed
HQ CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
SPECIAL REPAIR TO BUILDING NO P-29, (273 TO 280) P-112, (01TO 08), P-113 (01 TO 08) TOTAL 24 QTRS IN KSE ENCLAVE AT PATIALA
2025_MES_744281_1
CWE/PAT/T-60/2025-26
Open Tender
Civil Works
270 days
GE N PATIALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹2.0 L
16 Mar 2026
12 Dec 2025
21 Jan 2026
12 Dec 2025
19 Jan 2026
12 Jan 2026
12 Dec 2025 - 26 Dec 2025
itemH1Code197
Material and labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cement concrete 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 45mm to maintain slope of 1:100, complete all as specified andas directed by Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by Engineer-in-charge
Material and labour for laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer 0.40 Itr/sqm by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70-160 cps Over the coat, the layered APP membrane shall be laid using butane torch and sealing all joints etc complete as per standard practice and as per manufacturers instructions.complete all as specified and as directed by Engineer-in-charge.
Material and labour cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregates as in mud stops, benching and coping etc rounded or chamfered on edges complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair PVC (SWR) bends/tees of any radius for 150mm bore complete all as specified and as directed by Engineer-in-charge.
Material and labour for Non - skid Ceramic coloured tiles 7-8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry laid over and including 15 mm thick screed bed in cement mortar (1:4) and pointed in white or coloured cement to match the tiles complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350 mmx 250 mm x 7 mm/ 450mmX 300mmX 7mm thick as on vertical surface such as skirting , dado etc set and jointed in neat cement slurry . over and including 10 mm thick rendering in cement mortar 1:4 thick and pointed in white or coloured cement to match the tiles complete all as specified and as directed by Engineer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-charge.
Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and as directed by Engineer in charge.
Supply and fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair vitreous china premium/1st quality wash basin,flat back, size 550x400 mm with pedestal, including cutting for and pinning in ends of brackets including brackets and 32 mm brass CP waste coupling and waste pipe complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair flushing cistern of PVC 10 ltr. capacity. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair Salt-glazed stoneware gully traps,Centrifugal type 150x150mm size, square or round mouthed, type 'P' or 'S' including CI grating complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair Cast iron floor trap,dia of outlet 100 mm with grating including jointing to waste pipe with solvent cement fixed/ embedded in cement concrete type B-1 1:2:4 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing doubled layered rotational moulded polyethylene white water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including 20mm ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank with grating complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to storecomplete all as specified and directed by Engineer-in-Charge.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing in repair Chromium plated shower roses 125 mm size with or without swivel joints,including fixing to15mm bore dia steel pipe or union complete all as specified and directed by Engineer-in-Charge. .
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar , including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles, omplete all as specified and directed by Engineer-in-Charge.
Material and labour for Brickwork with old size subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in with cement mortar(1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Brick work with old size sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm including cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Mild Steel Pressed steel frames of size 125x60mm made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Mild Steel Pressed steel frames of size 105x 60mm made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,complete all as specified and directed by Engineer-in-Charge.
Supply and fixing factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass,gauze etc (without sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Pt-I section 8 clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete type B-1 1:2:4 complete all as specified and directed by Engineer-in-Charge.
Material labour for cement concrete (1:2:4 ) type B1 using 12.50 mm graded aggregate as filling in backof pressed steel /Holdfast Block etc complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing stainless steel Butt hinges 100 mm size,medium weight complete all as specified and directed by Engineer-in-Charge.
Supply and fixing aluminium alloy, anodised, sliding door bolt 250 mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing aluminium anodised, barrel tower bolts of 200 mm size of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stainless Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc for curtain rod incl all fixing complete all as specified and directed by Engineer-in-Charge.
Taking down chokhats or frames (without taking off shutters from the frame) n.exc 1.50 sqm including cutting holes of reqd size for hold fast block for new frame and making good the surface to match omplete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification complete all as specified and as directed by Engineer-in-Charge.
Material and labour for built in cup boards with pressed steel frame of size 75x45x1.25mm thick and shutter
Material and labour for Preparation of new wood surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primeromplete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturer's instructions and all as specified. Note : The application of rust removal shall be got done through the authorised applicator of manufacturer of membrane only complete all as specified and as directed by Engineer-in-Charge.. Make/Product: Sika Rustoff 100 or equivalent from Fosroc.
Supply and applying cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge. Note: The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
Material and labour for providing ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge. Consumption: o.5 kg/m2 complete all as per manufacturers instructions omplete all as specified and as directed by Engineer-in-Charge. Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C. Note: The application of epoxy bonding primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
Supply and fixing Continuous (piano) hinges,mild steel, bright finish or electro galvanised width of flaps 30 mm(when open) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Stainless Steel 304 grade wire Basket of pull out type like plain/cup&saucer/bottle/multi purpose/2-3 shelf baskets etc. for kitchens of required suze complete fixed in position complete all as specified and as directed by Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator
, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. including raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for rendering 15mm thick in two layers (10mm and 5mm respectively) on brick work or concrete surfaces or in chajjas/parapet walls etc in cemet mortar 1:4, mixing with liquid water proofing compound as per manufacturer's instructions, finished even and fair without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC and chicken wire gauge will be measured and paid separately.
Material and labour for rndering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material and labour forrendering 5 mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder on brick work or concrete surfaces or in chajjas/parapet walls etc complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying ready made wall care putty on internal/external plastered surfaces of walls /ceilings /soffits (thickness vary from 2 to 3 mm as required for desired smoothness and levelling of surfaces in two or more layers) including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying two coats of interior oil bound distemper (light shade) on surface of walls , over & including a coat of interior wall primer as recommended for under coat by manufacturer of OBD and primer complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified.
Supply and fixing Call bell ding dong AC 230 volt single pole complete all as specified.
Supply and fixing in repair MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and as directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized iron earth plate electrode of size
600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497 including taking out old u/s earthing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 50 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in plinth protection/ floor, surfaces finished even and smooth without using extra including provision of construction joints filled with Bituminous mastic asphalt complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and as directed by Engineer-in-Charge.. Notes:- (i) Switches and regulators shall be measured and paid for separately. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth. (iii) The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item. (iv) The cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. (v). Rate of cutting chasing included in the unit rate quoted for this item.
Material and labour for repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and as directed by Engineer-in-Charge.
All as per Sl item No 110.00 here-in- before but for one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and as directed by Engineer-in-Charge. .
All as per Sl item No 110.00 here-in-before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No.110.00 here-i-n before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH copper earth wire for switch socket combination 3 pin 15 amps on independent board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular switch 2 way, 6 Amps, 1 module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular bell push switch 1 way, 6 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Modular Fan regulator step type, 120 watts, 2 module complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite surface 65 x 50mm 3 terminals complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Lamp holder, PVC/ Polycarbonate type with back plate complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan/bell in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and as directed by Engineer-in-Charge.. Notes:- (i) Switches and regulators shall be measured and paid for separately. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth. (iii) The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item. (iv) The cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. (v). Rate of cutting chasing included in the unit rate quoted for this item.
Material and labour for replacement of sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire complete all as specified and as directed by Engineer-in-Charge. Notes :- (i) 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit (ii) Rate quoted for this items shall be inclusive of the cost of (iii) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (iv) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth .
Supply and fixing in repair MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified and as directed by Engineer-in-Charge. Notes :- MCCB will be measured and paid under seperate item (ii) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (iii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iv) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size.
Material and labour for replacement of sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire complete all as specified and as directed by Engineer-in-Charge. Notes :- (i) 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit (ii) Rate quoted for this items shall be inclusive of the cost of (iii) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (iv) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth .
Supply and fixing in replacement sheet metal enclosure 8 ways do
Material and labour for mild steel framed work as in brackets etc for cooler stands,supportings frame work for sun shade etc framed steps/stairs etc complete using MS railing/angle iron Steel bars, gusset plate etc complete all as specified and as directed by Engineer-in-Charge.
uble door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP 43 protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable complete all as specified and as directed by Engineer-in-Charge.
Taking down and refixing of ceiling fan after necessary cleaning painting and writing serial No. complete all as specified and directed by Enginner-in-charge.
Supply and fixing Elegatly designed sleek surface mounted pressure die-cast aluminium LED luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver of capacity 20 W LED of 5000 K and making good the existing surface as per existing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including louvers and taking down u/s exhaust fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing exhaust fan AC single phase 230/240 v of size 250 mm sweep 900 rpm Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including louvers and taking down u/s exhaust fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of Electric Water heater (Geyser) storage type of capacity 25 ltr BEE 5 star rated, ABS body, metal tank with glass lined coating multiple heating option, shock safe plug puf insulation, incoly glass coated anode rod/copper heating element with ISI mark, adjustable knob for temp setting with minimum & high working pressure, multi functinoal saftey value, & whirl/swril flow technology, themostat electronic type, complete including superior quality PVC connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per exisiting surface connection to inlet and outlet valves, testing complete all as specified and as dirceted by Engineer-in-Charge.
Supply and fixing LED lamp invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt, Lithium ion battery including removing of unserviceable lamp complete all as specified and as dirceted by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and as dirceted by Engineer-in-Charge.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and as dirceted by Engineer-in-Charge.
Supply and fixing Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified and as directed.
Supply and fixing Modular bell push switch 1 way, 6 Amps, 1 module complete all as specified and as directed.
Supply and fixing Call bell ding dong AC 230 volt single pole ccomplete all as specified and as directed.
Supply and fixing Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified and as directed.
Supply and fixing Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified.
Supply and fixing Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified.
Supply and fixing ceiling rose,3 phase/PVC/ polycarbonate, isolated boday complete all as specified and as directed.
Supply and fixing Lamp holder including LED bulb 9 W and flexible wire 0.5 Sqmm copper cable complete all as specified and as directed.
Supply and fixing in replacement of unsv bldg security light with new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket of 20 mm bore light grade GI pipe bend to shape, MS clamp fabricated out of 50x5 mm flat iron of required size and PVC1.5 Sqmm twin core cable from ceiling rose to light fittings complete all as specified and as directed.
Supply and fixing in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable complete all as specified and as directed.
Material and labour for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth Including taking out/down existing unserviceable sub main wiring all as specified and directed. Notes:- (A) 2(two) Runs of 6.00 Sqmm Copper conductor cable,1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit. (B) Rate quoted for this items shall be inclusive of the cost of following:- (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth.(iii) taking out/down existing unserviceable sub main wiring.
Supply and fixing in replacement of MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 54 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and as directed. Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size.
Supply and fixing in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified and as directed.
Supply and fixing in replacement of MCB , SPN B curve, 240 Volts ,32-40 amp for fixing in DBs including proper thimble connections complete all as specified and as directed.
Supply and fixing in replacement of MCB, single pole C curve 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and as directed.
Material and labour for replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497 complete all as specified and as directed. .
Supply and fixing Tube light fitting Self Ballasted LED Batten, Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity, 20 watt,4 ft long including 3 core flexible wire 0.5 sqmm copper cable complete all as specified and as directed.
Supply and fixing elegatly designed sleek surface mounted pressure die-cast aluminium LED luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver of capacity 12 W LED of 5000 K and making good the existing surface as per existing complete all as specified and as directed.
Supply and fixing Exhaust fan AC single phase 230/240 V of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louvers and make the surface good to match the existing surface complete all as specified and as directed.
Supply and fixing Exhaust fan AC single phase 230/240 v of size 250 mm sweep 900 rpm Engineering thermoplastic body,high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louvers and make the surface good to match the existing surface complete all as specified and as directed.
Supply and fixing/laying XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core and connection with appropriate size of Al thimble including taking out/down unsv cable complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and as directed.
Returning filling in including spreading, levelling and well ramming in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and as directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and as directed..
Material and labour for sand cushioning for protection of underground cable using dry fine river sand laid in trenches 8 cm before laying the cable and 15 cm after laying the cable including spreading, leveling, well ramming completed all as specified and as directed.Note:- Only punned depth will be measured for payment
Material and labour for Cutting the hardstanding, floor/wall of any thickness, description and in any location for laying of cable including making the surface good using cement concrete to match with the existing suface complete all as specified and as directed.
Material and labour for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and as directed. Note: GI pipe shall be measured and paid seperately under relevant item of this schedule.
Supplying and laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as specified and as directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor,along the wall or along the pole complete all as specified and directed.
Taking down and refixing of ceiling fan of any sweep after overhauling, replacement of capacitor and capaci
Taking down and refixing of ceiling fan any sweep after rewinding ,replacement of bearing, capacitor and capacitor stand,cleaning and painting with spray painting machine using synthetic enamel paint and writing serial No/MES NO with synthetic enamel paint of coluor and size of words as directed by Enginner-in-charge complete all as specified and as directed.Note:- The cost of supply & fixing of celing fan box round cover plate is included in the unit rate quoted by contractor.
tor stand,cleaning and painting with spray painting machine using synthetic enamel paint and writing serial No/MES NO with synthetic enamel paint of coluor and size of words as directed by Enginner-in-charge complete all as specified and as directed. Note:- The cost of supply & fixing of celing fan box round cover plate is included in the unit rate quoted by contractor.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Supply and fixing Electric Water heater (Geyser) storage type of capacity 25 ltr BEE 5 star rated, ABS body, metal tank with glass lined coating multiple heating option, shock safe plug puf insulation, incoly glass coated anode rod/copper heating element with ISI mark, adjustable knob for temp setting with minimum & high working pressure, multi functinoal saftey value, & whirl/swril flow technology, themostat electronic type, complete including superior quality PVC connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per exisiting surface connection to inlet and outlet valves, testing complete all as specified and as dirceted.
Material and labour for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire including taking down the existing unsv sub main wiring complete all as specified and as directed. Notes :- (1). 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.00 Sqmm Copper conductor Earth wire shall be measured as one unit) (2) Rate quoted for this items shall be inclusive of the cost of:- (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
Supply and fixing metal flush box of 1/2 module complete all as specified and as directed.
Supply and fixing metal flush box of 3 module complete all as specified and as directed.
Supply and fixing metal flush box of 6 module complete all as specified and as directed.
Supply and fixing metal flush box of 8 module complete all as specified and directed.
Supply and fixing modular cover plate of 1 module with frame complete all as specified and directed.
Supply and fixing modular cover plate of 2 module with frame complete all as specified and as directed.
Supply and fixing modular cover plate of 3 module with frame complete all as specified and as directed.
Supply and fixing modular cover plate of 6 module with frame complete all as specified and as directed.
Supply and fixing modular cover plate of 8 module with frame complete all as specified and as directed.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_833408.xls
BOQ • 0.43 MB
TENDER602526.pdf
Tender Documents • 1.35 MB
Download all tender documents and submit your bid