Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹24.8 LAccepted-AOC | ₹24.8 L | L2 | Accepted-AOC L1 |
| 2 | L1₹23.3 LRejected-AOC | ₹23.3 L | L1 | Rejected-AOC - |
| 3 | L3₹26.2 LRejected-AOC | ₹26.2 L | L3 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | ANNALAKSHMI P L2 | CLASSIC ENGINEERING L3 | P.MUTHUPANDI L1 |
|---|---|---|---|---|---|---|
| 1.01 | Dismantling the existing BT Road surface for pipeline work etc., complete. | 19 | M3 | 994.1 ₹18,887.90 | 1,049.8 ₹19,946.20 | 935.38 ₹17,772.13 |
| 2.01 | Removing the Existing Paver block M40 grade 80mm thick & 60mm thick in the rate including Removing and Stock to the Same Site and tranporting loading unloading and Labour Charges and Other tools etc.complete as per standard specification,. | 19 | M2 | 172.8 ₹3,283.20 | 182.5 ₹3,467.50 | 162.62 ₹3,089.78 |
| 3.01 | Earthwork excavation below water level in light or sandy soil for infiltration gallery, syphon or connecting pipe line and connected works including shoring and strutting and charges for special tools and plants for bailing/ pumping etc., such as air compressor and helmet.(RATES FOR EARTHWORK EXCAVATION PIPE LAYING WORKS FORWATER SUPPLY AND SEWERAGE WORKS)For 200mm D.I K9 Pipe | 240 | Rm | 289.9 ₹69,576 | 306.1 ₹73,464 | 272.75 ₹65,460.10 |
| 4.01 | Supply of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 Etc.Complete.. | 240 | Rm | 2,993.8 ₹7.2 L | 3,161.5 ₹7.6 L | 2,816.99 ₹6.8 L |
| 5.01 | Supply of M.S. PIPES- SPIRAL/LONGITUDIDNAL WELDING AS PER IS 3589/2001 WITH INTERNAL LINING AND EXTERNAL COATING MADE WITH FE410, Bare pipe per metre, CML Internal 6mm to 12mm thick per metre as per table of IS 3589, External epoxy
Coating 406 micr. per metre etc., complete. 219.1X6.3mm M.S Pipe( =2581.30 +482.50+ 769.30 1034.40+ 362.90 =5230.40) | 5 | Rm | 5,225.2 ₹26,126 | 5,517.8 ₹27,589 | 4,916.58 ₹24,582.88 |
| 6.01 | 200mm Sluice Valve | 2 | No | 27,386.6 ₹54,773.20 | 28,920.2 ₹57,840.40 | 25,769.16 ₹51,538.32 |
| 7.01 | 200mm NRV | 1 | No | 16,035.9 ₹16,035.90 | 16,933.9 ₹16,933.90 | 15,088.88 ₹15,088.88 |
| 8.01 | 200mm D.I TEE | 43 | kg | 146.6 ₹6,303.80 | 154.8 ₹6,656.40 | 137.9 ₹5,929.61 |
| 9.01 | 200mm D.I Bend | 99 | kg | 146.6 ₹14,513.40 | 154.8 ₹15,325.20 | 137.9 ₹13,651.90 |
| 10.01 | 100mm - 200 mm dia SOCKET | 69 | kg | 146.6 ₹10,115.40 | 154.8 ₹10,681.20 | 137.9 ₹9,514.96 |
Tender Value
₹24.8 L
EMD Value
₹24,827
Closing Date
5 Jan 2026, 3:00 pmClosed
The Commissioner Madurai Corporation
Aringar Anna Maligai , Thallakulam , Madurai
Providing 200mm D.I K9 Pipe line in Jawahar Street to Government New T.A.E.I Hospital Sump at Ward No 30
2025_MAWS_634380_1
Z4 / E8 / Est.373 / 25-26
Open Tender
Civil Works
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹24,827
19 Feb 2026
23 Dec 2025
5 Jan 2026
23 Dec 2025
5 Jan 2026
23 Dec 2025
Amount
Dismantling the existing BT Road surface for pipeline work etc., complete.
Removing the Existing Paver block M40 grade 80mm thick & 60mm thick in the rate including Removing and Stock to the Same Site and tranporting loading unloading and Labour Charges and Other tools etc.complete as per standard specification,.
Earthwork excavation below water level in light or sandy soil for infiltration gallery, syphon or connecting pipe line and connected works including shoring and strutting and charges for special tools and plants for bailing/ pumping etc., such as air compressor and helmet.(RATES FOR EARTHWORK EXCAVATION PIPE LAYING WORKS FORWATER SUPPLY AND SEWERAGE WORKS)For 200mm D.I K9 Pipe
Supply of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 Etc.Complete..
Supply of M.S. PIPES- SPIRAL/LONGITUDIDNAL WELDING AS PER IS 3589/2001 WITH INTERNAL LINING AND EXTERNAL COATING MADE WITH FE410, Bare pipe per metre, CML Internal 6mm to 12mm thick per metre as per table of IS 3589, External epoxy Coating 406 micr. per metre etc., complete. 219.1X6.3mm M.S Pipe( =2581.30 +482.50+ 769.30 1034.40+ 362.90 =5230.40)
200mm Sluice Valve
200mm NRV
200mm D.I TEE
200mm D.I Bend
100mm - 200 mm dia SOCKET
100mm - 200 mm dia FLANGE
16 mm dia x 65 to 90 mm length fully threaded bolts and nuts with 2 Nos.
Rubber Sheet
Spun Yarn ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =160 *20% =32.00 =Say =192.00)
Lead Wood ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =650 *20% =130.00 =Say =780.00)
Quicke Setting Cement ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =160 *20% =32.00 =Say =192.00)
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. 200mm D.I K9 pipe
Testing of pipes for water supply / Sewage with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes. (200 mm D.I K9 Pipe)&(219.1X6.3mm M.S Pipe) 200mm D.I K9 pipe
Providing Thrust Block arrangement as per the degree of the M.S pipe with Earth work excavation, P.C.C. 1:4:8, Shuttering work, R.C.C 1:1.5:3, RTS Rod and refilling etc., complete
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) 200mm D.I K9 pipe
Providing Inter Connection works for all type of Main Pipe arrangement and . The rate include the cost of all labour and material charges etc., complete.
Refilling with excavated soil (other than sand) complying with the standard specification for filling in foundation and basement etc., complete. For 200mm D.I K9 Pipe
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum sixdigit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/ sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accor dance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished.
Providing and laying,spreading and compacting 0.396m3 of 45-22.40mm &0.528m3 of 22.40-2.36mm &0.396m3 of2.36mm and below metal graded stone aggregate to wetmix macadam (WMM) so ecification including premixing the material with water at OMC in mechanical mixplant carriage to mixed material by tipper to site laying in uniform layers with paver insubbase /base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as perclasue 406 of MORTH specifications.
Plain Cement Concrete 1:2:4 (one cement, two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standardspecification
Constrution of Valve champer in Earth Work , Pcc 1 : 4 : 8 , Shutering Side , MS Grill , RCC 1 : 1.50 : 3 , In Valve Champer inner size in 1.50m x1.50m x 1.50m including Labours, loading & Unloading Charges Etc Completed.
Add GST 18%
ANNALAKSHMI P (BID ID -1552702)
CLASSIC ENGINEERING (BID ID -1552704)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Doc.pdf
Tender Documents • 0.93 MB
BOQ_759076.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid